Skip to content

Changes in Blood Flow in the Application of Magnetic Tape in Patients With Low Back Pain. RCT

Changes in Blood Flow in the Lower Limb With the Application of Magnetic Tape in Patients With Low Back Pain. Double-blinded Clinical Trial.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04836468
Enrollment
22
Registered
2021-04-08
Start date
2021-06-28
Completion date
2021-08-06
Last updated
2022-02-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Low Back Pain

Keywords

magnetic tape, Pressure, Pain, Vascular, Ultrasound

Brief summary

A tape is applied over the lumbar 4th and lumbar 5th levels crosswise in people with low back pain. The possible variation of the arterial flow of the femoral artery is measured with ultrasound. A kinesiology tape was used as placebo tape and Magnetic Tape was used as experimental randomly.

Detailed description

A double-blind randomized clinical trial is designed where subjects with low back pain will be selected and blinded to recieve the Magnetic Tape® (tape with magnetic effects of less than 2 Gauss) or placebo Tape. Likewise, the evaluator who puts the Magnetic Tape® does not know what material he is using, as it is supplied by another researcher. The sonographer also does not know if the patient has low back pain or not or what tape will be placed on him. The recommendations of the Consolidated Standards of Reporting Trials (CONSORT) will be followed. All participants will receive a participant information sheet and sign informed consent. Patients aged 18 to 65 years with low back pain will be recruited from different private clinics in the city of Valencia, Spain. The hypothesis is that when Magnetic Tape® comes into contact with electromagnetic fields such as those generated by living beings, due to the movement of electrical charges (ions), as defined by Ampere's Law, the domains of the tape are oriented or aligned in parallel with the external magnetic field creating a magnetic flux with a north pole and a south pole. This generated field in turn produces a magnetic induction proportional to the variation of the magnetic flux, as defined by the Faraday Law. This electric potential produces a redistribution of the electric charge (ions) generating a magnetic field due to the orientation of the tape domains, then exerting a force on the moving charges within the electrolyte. Physiological, Lorentz's Law, regulating Magnetic Tape® aberrant electromagnetic fields. The protocol for data collection will be as follows: After signing the informed consent and data protection, the groups with low back pain will be formed that will receive the application of both Magnetic Tape® and the intervention of a placebo tape. To avoid that the order of the intervention influences the results of the study, the subjects will be randomized into two different groups, Group A and Group B. Group A will receive Magnetic tape® and Group B will do the opposite. To standardize the location of the tape application, the patient will be placed in the prone position and the L4 spinous processes will be identified by marking them with a pen. Once L4 is located at the level of the iliac crests, the therapist will palpate the next spinous process down to the level of L5, and then it will be marked. The tape will be applied transversely covering the paravertebral skin at both levels. Afte this protocol ultrasound will be applied, evaluating the characteristics of blood flow by means of ultrasound in the common femoral artery using pulsed power doppler. An Alpinion ECube 12 ultrsound machine with a L3-12H linear probe with a 64 mm footprint will be used. The variables of Peak systolic PS velocity in (cm/s), peak diastolic velocity (DF) in (cm/s), the difference between distolic an systolic (S/D), the pulsatility index (PI), the resistance index (IR) and the artery diameter in (cm) will be taken. To assess pressure pain in the spinous processes, a Wagner Force Dial - FDK 20 algometer with a circular contact surface of 1 cm2 will be used. The sensation of perceived pain will be performed on the paravertebral skin of each level using the pinch technique and assessing it with the VAS scale. Both the algometer and pinch measurements will be repeated twice at each level leaving at least 1 minute between measurements. During the pain measurement phase, each participant will be in the prone position where assessments will be made from L1 to S4. Afterwards, they will be placed in a supine position and for three minutes to adjust to the room environment and relax, the ultrasound measurements were taken. Subsequently, a tape will be placed and the perceived pain, pressure pain and vascular parameters will be measured again.

Interventions

DIAGNOSTIC_TESTTape application

Magnetic Tape or Kinesiology tape will be applied randomly with both the examiner and the subjects blinded.

Sponsors

Francisco Selva
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* The inclusion criteria will be subjects with low back pain aged 18-65 years residing in Valencia who wish to participate in the study.

Exclusion criteria

* not meeting the age requirement, having conditions that would be a contraindication to placing an adhesive bandage on the skin such as allergies, also being pregnant, having a pacemaker or people who have any contraindication of electromagnetic fields, neurological diseases or taking any medication that may interact with magnetic fields.

Design outcomes

Primary

MeasureTime frameDescription
peak systolic velocity (PSV)1 minutemaximum systolic velocity of the femoral artery in (cm / s)
peak diastolic velocity (PDV)1 minutefemoral artery peak diastolic velocity in (cm / s)
difference between systolic and diastolic (S / D)1 minutedifference between systolic and diastolic in the femoral artery
pulsatility index (PI)1 minuteassesses the peripheral resistance of blood vessels
resistance index (RI)1 minutereflects resistance to arterial flow
diameter1 minutediameter of each artery

Secondary

MeasureTime frameDescription
Algometria2 minutesreferred pain when pressing on the lumbar vertebral processes

Countries

Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026