Skip to content

Comparing Full vs. Partial Glottis View Using CMAC D-Blade Video Laryngoscope in Simulated Cervical Injury Patient

A Randomized Controlled Trial Comparing Full Glottis View vs. Partial Glottis View During Intubation Using CMAC D-Blade Video Laryngoscope in Simulated Cervical Injury Patient

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04833166
Enrollment
104
Registered
2021-04-06
Start date
2021-05-25
Completion date
2022-02-24
Last updated
2022-09-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Airway Complication of Anesthesia, Intubation; Difficult or Failed

Keywords

Glottic view, Intubation time, C MAC D- blade

Brief summary

Direct laryngoscope requires proper alignment of the oro-pharyngeal-laryngeal axis to provide an optimal glottic view for intubation. However, in cervical spine patients, this alignment is not possible thus resulting in an increased risk of fail intubations. D-blade comes with an elliptically tapered blade shape rising at the distal end to provide better glottic visualization in comparison with direct laryngoscopes. Hence, CMAC D-blade is preferred in simulated cervical spine injury where intubator needs to maintain a neutral neck position. However, intubation time may be significantly longer due to difficulty in negotiating the endotracheal tube pass vocal cord and impingement of endotracheal tube to the anterior wall of trachea. There is a study published Glidescope which is also a hyperangulated videolaryngoscope suggested that obtaining a partial glottic view of larynx may facilitate a faster and easier tracheal intubation when compare to a full glottis view. The aim of this study is to clinically evaluate the time of tracheal intubation in relation to the full glottic view vs. partial glottic view which is deliberately obtained when using CMAC D-blade video laryngoscopy in simulated cervical spine injury.

Detailed description

Direct laryngoscope requires proper alignment of the oro-pharyngeal-laryngeal axis to provide the best laryngeal view for intubation. In cervical spine patients, this alignment is not possible resulting in an increased risk of failed intubations. Difficult intubation and failed tracheal intubation are among the major causes of morbidity and mortality associated with anesthesia. In recent years, video laryngoscope has played an increasingly important role in the management of patients with unanticipated difficult or failed endotracheal intubation. When compared with a direct laryngoscope, the video laryngoscope achieved a better view of the glottis and a high rate of successful intubation. On comparing the C-MAC with the conventional Macintosh blade, a conventional C-MAC Macintosh blade 3 and D-blade have a blade angulation of 18° and 40° in the D-blade respectively. In addition, with D-blade is an elliptically tapered blade-shaped rising to distal. This highly angulated C-MAC D blade provides a better glottic visualization in comparison to the direct laryngoscopes and in simulated cervical spine injury. This resulted in successful intubation in routine induction of anesthesia and rescue intubation in patients with difficult airway with C-MAC D Blade. But in terms of intubation time, study has shown a significantly shorter time with C-MAC D Blade compared with other indirect laryngoscopes. This may be due to a common problem seen in indirect video laryngoscopy whereby a good glottic view does not always allow advancing the tube into the trachea. A study has been conducted on Glidescope which is also a hyperangulated blade suggested that obtaining a partial glottic view of larynx may facilitate a faster and easier tracheal intubation when compare to a full glottis view. Randomised controlled trial also showed that GlideScope and C-MAC D blade video laryngoscope using manual inline axial stabilization (MIAS) for tracheal intubation in patients with cervical spine injury/pathology were equally efficacious. The aim of this study is to clinically evaluate the time of tracheal intubation in relation to deliberately obtained full glottic view vs. partial glottic view when using CMAC D-blade video laryngoscopy in simulated cervical spine injury.

Interventions

DEVICECMAC D-blade videolaryngoscope with full or partial glottic view

Deliberate achieving full or partial glottic view on C MAC D-blade video laryngoscope and comparing time and ease of intubation with both arms

Sponsors

University of Malaya
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
21 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

* All patients with American Society of Anaesthesiologist (ASA) physical status I-III * Age (≥21-75 years old) * General anaesthesia requiring tracheal intubation * Provide written consent to participate in the study

Exclusion criteria

* Pregnancy * Body mass index (BMI) ≥ 35 * Condition requires rapid sequence induction * Need for fibreoptic intubation * Need for nasal intubation * Documented difficult airway during previous surgery * Recent (3 months) active ischemic heart disease * Recent (3 months) cerebrovascular disease * Acute exacerbation of respiratory disease (eg. Uncontrolled asthma, Chronic Obstructive Pulmonary Disease)

Design outcomes

Primary

MeasureTime frameDescription
Intubation timeduring the interventionThis is the time taken from CMAC laryngoscope blade passes patient's lip until the recording of first end tidal CO2 (EtCO2); assessed up to 120 seconds.
First attempt successful intubation attemptduring the interventionFirst intubation attempt success rate between two groups; assessed up to maximum 2 attempts

Secondary

MeasureTime frameDescription
Time to obtain glottic viewduring the interventionTime taken for from CMAC laryngoscope blade passes patient's lip until achieving assigned laryngoscopic view; assessed up to 120 seconds
Hemodynamic changesimmediately after the interventionBlood pressure, mean arterial pressure and heart rate recorded 1 min, 2.5 min then 5 min post intubation
Airway traumaimmediately after the surgeryIncidence of oral mucosal trauma, lip laceration, dental laceration; assessed up to discharge from operating theatre.

Countries

Malaysia

Outcome results