Noninvasive Biomarkers of Metabolic Liver Disease 1.1

Noninvasive Biomarkers of Metabolic Liver Disease 1.1

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04828551
Enrollment
40
Registered
2021-04-02
Start date
2021-03-18
Completion date
2021-11-20
Last updated
2023-07-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Nonalcoholic Steatohepatitis, Nonalcoholic Fatty Liver

Brief summary

NIMBLE is a comprehensive collaborative effort to standardize, compare, validate, and advance the regulatory qualification of imaging and circulating biomarkers to diagnose and stage nonalcoholic steatohepatitis (NASH), and to predict and assess response to therapeutic intervention (https://fnih.org/what-we-do/biomarkers-consortium/programs/nimble). This study focuses on estimating the repeatability and reproducibility of ultrasound elastography-based biomarkers across a range of fibrosis stages.

Detailed description

Study 1.1, is a prospective, two-center, short-term cross-sectional study to assess the reproducibility and repeatability of a set of specified ultrasound-based quantitative imaging biomarkers. The primary focus will be on imaging biomarkers of the liver fibrosis component of nonalcoholic fatty liver disease (NAFLD), rather than the steatosis or inflammation component. The rationale is that the fibrosis component is linked most closely to survival and other clinical outcomes. Study 1.1 will also collect data to explore vendor- or device-specific investigational biomarkers on other components of NAFLD such as steatosis and possibly inflammation.

Interventions

DEVICEUltrasound based shear wave speed and fat quantification methods

Ultrasound based imaging parameters will be collected from all patients in two visits. These will include but may not be limited to SWE results, Quantitative ultrasound parameters,where available,including Attenuation Coefficient, Backscatter Coefficient, Shear Wave Dispersion, Speed of Sound, Ultrasound derived fat fraction Conventional Bmode (gray-scale) and Doppler ultrasound images,including An image of the liver and right kidney on the same image for hepatorenal index calculation Right liver lobe for skin to liver capsule distance calculation Portal vein Doppler for portal vein pulsatility index measurement VCTE and Controlled Attenuation Parameter measurements with the Fibroscan system

DIAGNOSTIC_TESTBlood collection

Blood will be collected by trained phlebotomists at each site using routine methods and standard collection tubes. Total volume is expected to be about 10 mL or less Blood collected at MGH will be analyzed by the MGH clinical laboratory. Blood collected at UCSD will be analyzed by the UCSD clinical laboratory. Blood results obtained within the 3-month interval prior to the screening visit at the MGH or UCSD laboratories will be considered acceptable for study analyses and may be used at PI discretion. For each laboratory, the normal ranges for each blood test will be recorded and filed

Height will be recorded at Screening. Weight and vital signs will be recorded at each visit. Body mass index will be calculated at each visit. All measurements will be made by trained coordinators using standard and calibrated instruments.

OTHERClinical history and medication reviews

The following questionnaires will be administered at Screening: Medical history questionnaire Medication use questionnaire Alcohol consumption questionnaire Physical activity questionnaire The following questionnaires will be administered at Visit 1 and Visit 2: Interim medical history questionnaire Change in medication use questionnaire Change in alcohol consumption will be recorded using a modified version of the alcohol use followback. Alcohol use for the 7 day period prior to Visit 1 and for all days between Visit 1 and Visit 2 will be recorded. Change in physical activity questionnaire

Sponsors

University of California, San Diego
CollaboratorOTHER
Foundation for the National Institutes of Health
CollaboratorOTHER
Massachusetts General Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

Study participants will not be randomized to individual treatment groups. To ensure a uniform distribution of scanner combinations, participants will follow a block-allocation pattern with different scanner combinations for different participants, however, patients and operators will not be blinded to ultrasound scanners being used. All efforts will be made to keep ultrasound operators blinded to clinical and laboratory data, however, it is not believed that this will significantly affect the ultrasound acquisition. The Visit 2 operator will be asked to not review the Visit 1 exam results. Central analysts will be blinded to key clinical and laboratory findings to minimize potential bias. Blinding of the central analysts will be outlined in a separate Image Review Charter.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult (age ≥ 18 years) * Known or suspected NAFLD based on prior biopsy ≤ 36 months consistent with NAFLD OR * Abnormal ALT (\>30 U/L for men, \> 19 U/L for women) without other common causes such as HCV, HBV, AND meets criteria within 36 months for ATP III criteria (2005 revision) for metabolic syndrome with any 3 of the 5: Waist circumference (WC) \> 102 cm (M) or \> 88 cm (F) * Fasting glucose ≥ 100 mg/dL or Rx * TG≥150mg/dLorRx * SBP \> 130 mmHg * DBP\>85mmHg or Rx * Able and willing to participate, including maintaining steady-state: physical activity, alcohol use, medications * Classifiable into one of the following enrollment categories by FIB-4 (ALT, AST, platelets, date of birth) collected at screening visit if not available already within 3 months prior: Low likelihood of advanced fibrosis: FIB-4 ≤ 1.3 (about one-third of enrolled participants, minimum 8, maximum 18), Intermediate likelihood of advanced fibrosis: 1.3 \< FIB-4 \< 2.67 (about one-third of enrolled participants, minimum 8, maximum 18), High likelihood of advanced fibrosis: FIB-4 ≥ 2.67: (about one-third of enrolled participants, minimum 8, maximum 18)

Exclusion criteria

* Liver disease other than NAFLD * Excess alcohol consumption (≥ 2 units/day for women and ≥ 3 units/day for men) * Current diagnosis of drug induced liver injury * Receiving drug or placebo in treatment trial now or within 30 days * Weight loss or gain of ≥ 5 kg in prior 3 months * Other factors that in the judgment of the principal investigator might preclude study completion * Women who state they are pregnant. Women who state they are pregnant will be excluded in an abundance of caution, since pregnancy might increase intra-abdominal pressure which in turn might affect the assessment of the different-day reproducibility coefficient of ultrasound and VCTE measurements. Women who state they might be pregnant will be required to do a urine pregnancy test to establish eligibility. * Patients with active implants such as pacemakers or defibrillators or any other contraindication to ultrasound or VCTE scanning.

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of Pooled Different-day, Different-operator Reproducibility of Shear Wave Speed Measurements(2 visits, baseline + up to 7 days). Outcome measure will be assessed after pooling measurements from all study subjects.The same research subject undergoes multiple shear wave elastography measurements (measured in m/s) on multiple ultrasound imaging devices and transient elastography at two visits (baseline + up to 7 days) with different operators. Elastographic measurements are recorded. The median shear wave velocity value (in m/s) is computed for each ultrasound imaging device and is displayed by the transient elastography device. The ultrasound machine measurements are pooled and the pooled different day-different operator reproducibility coefficient for the group of ultrasound machines is computed. The reproducibility coefficient for transient elastography is computed separately. The pooled different-day, different-operator reproducibility coefficient of ultrasound measurements of shear wave speed, is reported in the outcome measure data table section.
Different-day, Different-operator Reproducibility Coefficient of Transient Elastography Based Shear Wave Speed Measurements(2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling all measurements from all study subjects.The same research subject undergoes multiple shear wave elastography measurements (measured in m/s) on multiple ultrasound imaging devices and transient elastography at two visits (baseline + up to 7 days) with different operators. Elastographic measurements are recorded. The median shear wave velocity value (in m/s) is computed for each ultrasound imaging device and is displayed by the transient elastography device. The ultrasound machine measurements are pooled and the pooled different day-different operator reproducibility coefficient for the group of ultrasound machines is computed. The reproducibility coefficient for transient elastography is computed separately. The pooled different-day, different-operator reproducibility coefficient of transient elastography measurements (in m/s unit), is reported in the outcome measure data table section.

Secondary

MeasureTime frameDescription
Evaluation of Pooled Same-day, Same-operator Repeatability of Shear Wave Speed (SWS)(2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling measurements from all study subjects.The same research subject undergoes multiple SWE measurements (in m/s) on multiple devices and transient elastography (TE) at two visits (in 7 days) with different operators. For this outcome measure, the same-day same-operator repeatability is estimated on repeated measurements performed on the same device by the same operator at the same visit. For example, the following structure is followed for a subject; Day1 (Device A, Device B, Device C, TE, Repeated Device A, Repeated Device B), Day2 (Device A, Device B, Device C, TE, Repeated Device C, Repeated TE). The median SWS value (in m/s) is computed for each ultrasound device and is displayed by the TE device. The pooled same-day, same-operator repeatability coefficient of ultrasound measurements of SWS, is reported in the outcome measure data table section.
Evaluation of Pooled Different-scanner, Same-day Reproducibility of Shear Wave Elastography.(2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling all measurements from all study subjects.The same research subject undergoes multiple shear wave elastography measurements (measured in m/s) on multiple ultrasound imaging devices and transient elastography at two visits (baseline + up to 7 days) with different operators. The median shear wave velocity value (in m/s) is computed for each ultrasound imaging device and is displayed by the transient elastography device. The reproducibility coefficient of measurements obtained across different ultrasound devices on the same day by the same operator is computed. For example, the following structure is followed for a study subject; Day1 (Device A, Device B, Device C, Transient elastography, Repeated Device A, Repeated Device B), Day2 (Device A, Device B, Device C, Transient elastography, Repeated Device C, Repeated transient elastography).The pooled different-scanner, same-day reproducibility coefficient of ultrasound measurements of SWS, is reported in the outcome measure data table section.
Evaluation of Same-day, Same-operator Repeatability of Transient Elastography(2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling all measurements from all study subjects.Same day same operator repeat median TE measures expressed in m/s are compared and the repeatability is estimated. For example, the following structure is followed for a study subject; Day1 (Device A, Device B, Device C, Transient elastography, Repeated Device A, Repeated Device B), Day2 (Device A, Device B, Device C, Transient elastography, Repeated Device C, Repeated transient elastography), which allows estimation of same-day same operator repeatability.

Countries

United States

Participant flow

Participants by arm

ArmCount
MGH and UCSD Study Subjects
NAFLD patients with ultrasound elastography and fat quantification measurements
40
Total40

Baseline characteristics

CharacteristicMGH and UCSD Study Subjects
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
13 Participants
Age, Categorical
Between 18 and 65 years
27 Participants
Age, Continuous60.4 years
Ethnicity (NIH/OMB)
Hispanic or Latino
7 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
33 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
9 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
1 Participants
Race (NIH/OMB)
Unknown or Not Reported
1 Participants
Race (NIH/OMB)
White
29 Participants
Region of Enrollment
United States
40 participants
Sex: Female, Male
Female
24 Participants
Sex: Female, Male
Male
16 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 40
other
Total, other adverse events
0 / 40
serious
Total, serious adverse events
0 / 40

Outcome results

Primary

Different-day, Different-operator Reproducibility Coefficient of Transient Elastography Based Shear Wave Speed Measurements

The same research subject undergoes multiple shear wave elastography measurements (measured in m/s) on multiple ultrasound imaging devices and transient elastography at two visits (baseline + up to 7 days) with different operators. Elastographic measurements are recorded. The median shear wave velocity value (in m/s) is computed for each ultrasound imaging device and is displayed by the transient elastography device. The ultrasound machine measurements are pooled and the pooled different day-different operator reproducibility coefficient for the group of ultrasound machines is computed. The reproducibility coefficient for transient elastography is computed separately. The pooled different-day, different-operator reproducibility coefficient of transient elastography measurements (in m/s unit), is reported in the outcome measure data table section.

Time frame: (2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling all measurements from all study subjects.

ArmMeasureValue (NUMBER)
MGH and UCSD Study SubjectsDifferent-day, Different-operator Reproducibility Coefficient of Transient Elastography Based Shear Wave Speed Measurements35.6 Reproducibility coefficient (in %)
Primary

Evaluation of Pooled Different-day, Different-operator Reproducibility of Shear Wave Speed Measurements

The same research subject undergoes multiple shear wave elastography measurements (measured in m/s) on multiple ultrasound imaging devices and transient elastography at two visits (baseline + up to 7 days) with different operators. Elastographic measurements are recorded. The median shear wave velocity value (in m/s) is computed for each ultrasound imaging device and is displayed by the transient elastography device. The ultrasound machine measurements are pooled and the pooled different day-different operator reproducibility coefficient for the group of ultrasound machines is computed. The reproducibility coefficient for transient elastography is computed separately. The pooled different-day, different-operator reproducibility coefficient of ultrasound measurements of shear wave speed, is reported in the outcome measure data table section.

Time frame: (2 visits, baseline + up to 7 days). Outcome measure will be assessed after pooling measurements from all study subjects.

ArmMeasureValue (NUMBER)
MGH and UCSD Study SubjectsEvaluation of Pooled Different-day, Different-operator Reproducibility of Shear Wave Speed Measurements30.7 Reproducibility coefficient (in %)
Secondary

Evaluation of Pooled Different-scanner, Same-day Reproducibility of Shear Wave Elastography.

The same research subject undergoes multiple shear wave elastography measurements (measured in m/s) on multiple ultrasound imaging devices and transient elastography at two visits (baseline + up to 7 days) with different operators. The median shear wave velocity value (in m/s) is computed for each ultrasound imaging device and is displayed by the transient elastography device. The reproducibility coefficient of measurements obtained across different ultrasound devices on the same day by the same operator is computed. For example, the following structure is followed for a study subject; Day1 (Device A, Device B, Device C, Transient elastography, Repeated Device A, Repeated Device B), Day2 (Device A, Device B, Device C, Transient elastography, Repeated Device C, Repeated transient elastography).The pooled different-scanner, same-day reproducibility coefficient of ultrasound measurements of SWS, is reported in the outcome measure data table section.

Time frame: (2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling all measurements from all study subjects.

ArmMeasureValue (NUMBER)
MGH and UCSD Study SubjectsEvaluation of Pooled Different-scanner, Same-day Reproducibility of Shear Wave Elastography.52.7 Reproducibility coefficient (in %)
Secondary

Evaluation of Pooled Same-day, Same-operator Repeatability of Shear Wave Speed (SWS)

The same research subject undergoes multiple SWE measurements (in m/s) on multiple devices and transient elastography (TE) at two visits (in 7 days) with different operators. For this outcome measure, the same-day same-operator repeatability is estimated on repeated measurements performed on the same device by the same operator at the same visit. For example, the following structure is followed for a subject; Day1 (Device A, Device B, Device C, TE, Repeated Device A, Repeated Device B), Day2 (Device A, Device B, Device C, TE, Repeated Device C, Repeated TE). The median SWS value (in m/s) is computed for each ultrasound device and is displayed by the TE device. The pooled same-day, same-operator repeatability coefficient of ultrasound measurements of SWS, is reported in the outcome measure data table section.

Time frame: (2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling measurements from all study subjects.

ArmMeasureValue (NUMBER)
MGH and UCSD Study SubjectsEvaluation of Pooled Same-day, Same-operator Repeatability of Shear Wave Speed (SWS)21 Repeatability coefficient (in %)
Secondary

Evaluation of Same-day, Same-operator Repeatability of Transient Elastography

Same day same operator repeat median TE measures expressed in m/s are compared and the repeatability is estimated. For example, the following structure is followed for a study subject; Day1 (Device A, Device B, Device C, Transient elastography, Repeated Device A, Repeated Device B), Day2 (Device A, Device B, Device C, Transient elastography, Repeated Device C, Repeated transient elastography), which allows estimation of same-day same operator repeatability.

Time frame: (2 visits, baseline + up to 7days). Outcome measure will be assessed after pooling all measurements from all study subjects.

ArmMeasureValue (NUMBER)
MGH and UCSD Study SubjectsEvaluation of Same-day, Same-operator Repeatability of Transient Elastography19.6 Repeatability coefficient (in %)

Source: ClinicalTrials.gov · Data processed: Feb 6, 2026