Ultrasound-Assessed Diaphragmatic Dysfunction as a Predictor of Weaning Outcome

Ultrasound-Assessed Diaphragmatic Dysfunction as a Predictor of Weaning Outcome in Mechanically Ventilated Patients With Sepsis in Intensive Care Unit

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04825509
Enrollment
60
Registered
2021-04-01
Start date
2021-04-18
Completion date
2021-11-01
Last updated
2022-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sepsis, Weaning Failure

Keywords

Diaphragm ultrasound, Weaning predictor

Brief summary

This study aims to assess whether the degree of diaphragm excursion and diaphragm thickening measured by ultrasound during a weaning trial may be used to predict successful weaning from mechanical ventilation in patients with sepsis in intensive care unit

Detailed description

After being informed about the study and giving written informed consent, Intubated and mechanically ventilated patients with sepsis on admission and fulfilling criteria of weaning from mechanical ventilation (MV), will undergo diaphragm ultrasound during spontaneous breathing trial on T-piece. We will measure diaphragm excursion (DE), diaphragm thickness (DT) and calculate diaphragm thickness fraction (DTF): DT during inspiration - DT during expiration / DT during expiration According to weaning outcome, patients will be divided into 2 groups: * Successful weaning group * Weaning failure group By statistical analysis we will define the cut off value and area under curve (AUC) for DE and DTF and we can confirm if DE and DTF using ultrasound can be used as predictors for weaning from MV or not

Interventions

DEVICEUltrasound

Diaphragm ultrasound will be done while patient is supine on T-piece during SBT 30 minutes after disconnecting mechanical ventilation. The measurements will be done by placing the transducer in the eighth or ninth intercostal space, between the anterior axillary and the mid-axillary lines. Diaphragmatic excursion (DE) will be measured in M-mode using a 1- to 5- Megahertz (MHz) ultrasound curved transducer during maximal breathing. The amplitude of diaphragmatic excursion will be measured as the point of maximal height of the diaphragm to the base line. Diaphragmatic thickness (DT) will be measured at both end of maximal inspiration and end of maximal expiration using a high frequency 7-11 MHz ultrasound linear transducer in M-mode. The diaphragm thickness will be measured from the middle of the pleural line to the middle of the peritoneal line.

Sponsors

Ain Shams University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* Patients of both sexes, aging 18 - 60 years after written informed consent * Patients with sepsis on admission according to the new sepsis definition in 2016 (life-threatening organ dysfunction due to a dysregulated host response to infection) * Hemodynamically stable without or with low dose support * Patients on mechanical ventilation for at least 48 hours and not more than 1 week * Patients ready for start of weaning protocol, fully conscious, on continuous positive airway pressure (CPAP) mode with positive end expiratory pressure (PEEP) 3-5 Centimetre water (CmH2O), Pr. Supp. \<15 CmH2O, Fio2 less than 60%, Respiratory rate less than 35 breath/min, partial oxygen pressure (PO2)/FIO2 \>200, Rapid Shallow Breathing Index (RSBI) is less than 105

Exclusion criteria

* Patients aged less than 18 years or more than 60 years old * Patients in septic shock, hemodynamically unstable or on high dose support * Patients on mechanical ventilation for more than 1 week or less than 48 hours * Patients not ready for start of weaning from mechanical ventilation * Patients with neuromuscular disorders * Pregnant females in the second and third trimester, patients with tense ascites or morbidly obese with body mass index more than 40 kg/m2

Design outcomes

Primary

MeasureTime frameDescription
Successful extubationfrom start of SBT till 48 hours after extubationextubation success or failure will depend on patient needs to MV during spontaneous breathing trial (SBT), or invasive or non-invasive ventilation within 48 hours after extubation according to: respiratory rate\>35/min, increased work of breathing, O2 saturation \<90% with fraction of inspired oxygen (FIO2)\>50%, new arrhythmias, increased heart rate\>20% or more than 140b/min, drop of 20 millimetre mercury (mmHg) or rise of 30 mmHg systolic blood pressure, increased systolic blood pressure \>180 mmHg in normotensive patient, change of 10 mmHg diastolic blood pressure and deterioration of blood gases value

Secondary

MeasureTime frameDescription
need for tracheostomyFrom start of SBT for 21 daysWe will check patient need for tracheostomy since start of weaning process for 21 days and the indication for tracheostomy, if due to prolonged intubation or other causes

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026