Skip to content

Hemodynamic Monitoring in Liver Transplant With VEnaRt Cardiac Output Versus Swan-Ganz Catheter (VERO Study)

Hemodynamic Monitoring in Liver Transplant With VEnaRt Cardiac Output Versus Swan-Ganz Catheter VERO Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04825015
Acronym
VERO
Enrollment
26
Registered
2021-04-01
Start date
2021-04-01
Completion date
2022-12-15
Last updated
2023-08-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Output, Low, Liver Transplant; Complications

Brief summary

The Swan-Ganz catheter is the gold standard to measure cardiac output during liver transplantation surgery. This is an invasive hemodynamic monitoring system. The VenArt Cardiac Output (Mespere LifeSciences, Waterloo, Canada) is a new, innovative and non-invasive device that permits hemodynamic monitoring. With a software based on Fick's principle it is able to calculate cardiac output, cardiac index and continuous cardiac output. The hypothesis of this study is to investigate the precision and accuracy of this method versus the standard of care during liver transplantation.

Interventions

DEVICEVEnaRt Cardiac Output

Every patient is monitored during liver transplantation with VEnaRt Cardiac Output versus Swan-Ganz Catheter

Sponsors

Azienda Sanitaria-Universitaria Integrata di Udine
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

* liver transplantation patients

Exclusion criteria

* age \< 18 years old * combined liver-kidney transplant * liver transplant for acute insufficiency * no consent of the patient

Design outcomes

Primary

MeasureTime frameDescription
Precision of VenArt Cardiac Output cardiac output, cardiac index and continuous cardiac output measuresDuring surgeryEvaluate the precision of VenArt Cardiac Output cardiac output, cardiac index and continuous cardiac output versus the pulmonary catheter in patients undergoing liver transplantation
Accuracy of VenArt Cardiac Output cardiac output, cardiac index and continuous cardiac output measuresDuring surgeryEvaluate the accuracy of VenArt Cardiac Output cardiac output, cardiac index and continuous cardiac output versus the pulmonary catheter in patients undergoing liver transplantation

Secondary

MeasureTime frameDescription
CorrelationDuring surgeryAnalyze the VenArt Cardiac Output and Swan-Ganz catheter statistical correlation of cardiac output and cardiac index measures
ConcordanceDuring surgeryAnalyze the VenArt Cardiac Output and Swan-Ganz catheter statistical concordance of cardiac output and cardiac index measures
Time of device positioningDuring surgeryEvaluate the time necessary to position the VenArt Cardiac Output and Swan-Ganz catheter
Device positioning complicationsDuring surgeryEvaluate the complication during the VenArt Cardiac Output and Swan-Ganz catheter positioning.

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026