Augmented Infant Resuscitator to Enhance Newborn Ventilation

Augmented Infant Resuscitator (AIR): Transitioning a Novel Behavior Change Innovation to Drive Newborn Ventilation Skills Enhancement

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04820504
Acronym
AIR
Enrollment
270
Registered
2021-03-29
Start date
2016-07-01
Completion date
2016-11-01
Last updated
2021-03-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Asphyxia Neonatorum, Birth Asphyxia, Perinatal Asphyxia

Brief summary

Augmented Infant Resuscitator (AIR) is an inexpensive add-on, compatible with nearly every existing bag-valve mask and many types of ventilation equipment. AIR monitors ventilation quality and provides real-time objective feedback and actionable cues to clinicians to both shorten training times and improve resuscitation quality, adoption, retention, and confidence.

Detailed description

Longitudinal, randomized control trial that examined the effectiveness of AIR among 270 participants, with 1,080 recorded ventilation scenarios, and across 20 sites in Uganda and the U.S. Birth attendants - including a mix of midwives, nurses, respiratory therapists, pediatricians, and neonatologists - with recent HBB and/or NRP training were recruited to participate in this randomized control trial. Participants ventilated training mannequins for a fixed duration of time. Participants were randomized to receive visual feedback from AIR (intervention) or have the AIR feedback covered (control). They were then requested to administer effective ventilation and verbally assess the mannequin condition. All mannequins appeared to be identical, but each session's mannequin was randomly selected with an upper airway that was normal, partially leaking, or partially obstructed.

Interventions

Device provides visual feedback related to air leak, obstruction, hyperventilation, hypoventilation, and harsh breaths

DEVICEAIR device without feedback

Device provides no visual feedback to clinician but records data on ventilation effectiveness

Sponsors

Massachusetts General Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Midwives, nurses, respiratory therapists, pediatricians, and neonatologists working as birth attendants in select hospitals in Uganda and the U.S. who are either previous trained in Helping Babies Breathe (HBB) and/or have a current Newborn Resuscitation Program (NRP) certification.

Exclusion criteria

* None

Design outcomes

Primary

MeasureTime frameDescription
Effective bag-mask ventilation2 minutesDuration of effective bag-mask ventilation by clinician during a 2-minute trial. \[This will be a cumulative duration of the two minutes. This is measured internally from the AIR device. Effective ventilation is defined as having all three of the following conditions simultaneously: (1) Correct rate (30-60 breaths per minute); (2) Absence of significant leak (compliance \>4.0mL/cm H2O); and (3) Absence of a significant airway blockage (defined as compliance \<0.10 mL/cm H2O or resistance \>90 cmH2O/L/s). These measurements are determined by sensors in the AIR device for both arms of the study. Their accuracy for manikin use was determined to be 100% in the following trial: Bennett el al. Anesth Analgesia. 2018 Mar;126(3):947-955. doi: 10.1213/ANE.0000000000002432.\]
Time to effective bag-mask ventilation2 minutesHow long it takes for clinician to achieve effective ventilation during 2-minute trial. \[This is time from when the mask first touches the face of the manikin until all three icons are green. This is measured by a Research Assistant using a stop-watch. Again, Effective ventilation is defined as having all three of the following conditions simultaneously and is indicated to the RA by all three icons on the AIR device turning green: (1) Correct rate (30-60 breaths per minute); (2) Absence of significant leak (compliance \>4.0mL/cm H2O); and (3) Absence of a significant airway blockage (defined as compliance \<0.10 mL/cm H2O or resistance \>90 cmH2O/L/s). These measurements are determined by sensors in the AIR device for both arms of the study. Their accuracy for manikin use was determined to be 100% in the following trial: Bennett et al. Anesth Analgesia 2018 Mar;126(3):947-955. doi: 10.1213/ANE.0000000000002432.\]
Clinician's correct assessment of mannequin airway issues2 minutesAbility of clinician to correctly assess three different manikin airway issues: normal, air leak, or obstruction. \[Manikin conditions are blinded to the participants and were either normal (as supplied by the manufacturer, had a leak insert (introduced compliance \>4mL/cm H2O), or had an obstruction insert (introduced a reduction in compliance \<0.10mL/cm H2O and resistance \>90 cm H2O/L/s. As per the parameters in the following paper: Bennett et al. Anesth Analgesia. 2018 Mar;126(3):947-955. doi: 10.1213/ANE.0000000000002432.\]