Skip to content

Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis

A Multicenter, Prospective, Single-Arm, Objective Performance Criteria Study to Evaluate the Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04815785
Enrollment
120
Registered
2021-03-25
Start date
2017-09-22
Completion date
2024-05-30
Last updated
2023-10-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis

Brief summary

To observe and evaluate the safety and efficacy of TaurusOne® transcatheter aortic valve system in patients with severe calcific aortic stenosis through a prospective, multicenter clinical trial using objective performance criteria.

Interventions

DEVICETaurusOne® transcatheter aortic valve replacement system

The TaurusOne® Transcatheter Aortic Valve System consists of an aortic valve, an associated delivery catheter and a loading system. The aortic valve consists of a self-expanding nitinol frame, a sealing skirt and valve leaflets, which are made of bovine pericardium. The delivery system is mainly composed of conical head, opacity ring, inner tube, top ring, middle tube, outer tube, booster rod, stress diffusion catheter, handle, etc. The outflow end of the aortic valve is provided with three fixing holes evenly distributed on the circumference on the top ring of the delivery catheter, so as to facilitate the installation, delivery and release of the aortic valve. Before the operation, the aortic valve needs to be installed into the sheath of the delivery catheter as required.

Sponsors

Fu Wai Hospital, Beijing, China
CollaboratorOTHER
Second Affiliated Hospital, School of Medicine, Zhejiang University
CollaboratorOTHER
West China Hospital
CollaboratorOTHER
General Hospital of Shenyang Military Region
CollaboratorOTHER
The Second Affiliated Hospital of Harbin Medical University
CollaboratorOTHER
Second Xiangya Hospital of Central South University
CollaboratorOTHER
Peijia Medical Technology (Suzhou) Co., Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
70 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients who voluntarily participate and sign the informed consent and are able to comply with the entire trial process; * Age ≥ 70 years; * Patients with severe calcific aortic stenosis confirmed by echocardiography (Transaortic flow velocity ≥ 4.0 m/s, or aortic-valve gradient ≥ 40 mmHg (1 mmHg = 0.133 kPa), or aortic valve area \< 0.8 cm2, or effective orifice area \< 0.5 cm2/m2); * Patients who have symptoms obviously caused by aortic stenosis, NYHA Class II or worse; * Patients who are unsuitable for conventional surgery evaluated by the cardiac team (including at least two cardiovascular surgeons) \[13\] \*; * Life expectancy after implantation of prosthetic valve is more than one year evaluated by the cardiac team (including at least two cardiac surgeons); * Aortic annulus diameter ≥ 18 mm and ≤ 29 mm (measured by cardiac CT); * Ascending aorta diameter \< 50 mm \*: If the patient meets any of the following criteria judged by a multidisciplinary cardiac team composed of cardiologists and cardiovascular surgeons, radiologists, anesthesiologists, etc. (at least two cardiovascular surgeons), the patient will be identified as unsuitable for conventional surgery (at least STS ≥ 8 points): * Estimated risk of surgery-related death or disability \> 50% within 1 year; * ≥3 major organ damage that could not be improved by surgery; * Obstacles related to surgical procedures judged as serious

Exclusion criteria

* Patients with bacteremia or toxemia; * Previous endocarditis or active endocarditis; * Acute myocardial infarction (Q-wave MI, or non-Q-wave MI with elevated creatine kinase isoenzyme and troponin T) within 30 days; * Any intracardiac mass, left ventricular or atrial thrombus, vegetation on echocardiography; * Symptomatic atrial fibrillation that cannot be improved by drug therapy; * Familial hypertrophic cardiomyopathy; * Mitral or tricuspid valve insufficiency (grade II regurgitation or higher); * Previous aortic valve graft (mechanical or bioprosthetic valve); * Known allergies to contrast agents, aspirin, heparin, ticlopidine drugs, nitinol shape memory alloy, or bovine products; * Known contraindications or allergies to anticoagulant regimens, or inability to use anticoagulants throughout the trial; * Other serious diseases that may reduce life expectancy to less than 12 months (such as clinically recurrent or metastatic cancer, congestive heart failure, etc.); * Current substance abuse problems (e.g., alcohol, cocaine, heroin, etc.); * Scheduled to undergo surgery that may result in protocol noncompliance or confounding in data interpretation. * Cerebrovascular accident (CVA) in the past 6 months; * Patients with common carotid artery or internal carotid artery or vertebral artery stenosis (\>70%); * White blood cell count \<3×109/L, platelet count \<50×109/L; * Hemoglobin \< 90 g/L; * Patients with severe coagulopathy; * Severe left ventricular dysfunction, left ventricular ejection fraction \< 20%; * Abdominal or thoracic aortic aneurysm; * Hepatic encephalopathy or acute active hepatitis; * On dialysis or baseline creatinine level \> 2.5 mg/dL (221 μ mol/L); * Bleeding tendency or history of coagulation disease or refusal of blood transfusion; * Patients with active peptic ulcer or active gastrointestinal (GI) bleeding; * Patients with neurological diseases that seriously affect mobility and activities of daily living; * Patients with mental illness or psychological disorders who are unable to communicate effectively; * Patients who need emergency surgery for any reason; * Patients who have participated in other drug or medical device clinical trials within 3 months prior to screening; * Other conditions that make the patient ineligible to participate in this clinical trial in judgement of investigators

Design outcomes

Primary

MeasureTime frameDescription
All-cause mortality at 12 months12 monthsAll-cause mortality

Secondary

MeasureTime frameDescription
Device success rate (Immediate after procedure)Immediate after procedure* Successful delivery and release of vascular access and prosthetic aortic valve, and successful withdrawal of the delivery catheter * Accurate placement of prosthetic aortic valve at the anatomical site * Prosthetic aortic valve meets the desired requirements (mean valve gradient \< 20 mm Hg or maximal flow velocity \< 3 m/s; No severe prosthetic valve regurgitation or perivalvular leak)
Procedure success rate72 hours after procedure/prior to dischargeA successful procedure is defined as successful implantation of the prosthetic aortic valve at the correct anatomical site 72 hours after the operation or before discharge without severe prosthetic valve regurgitation or perivalvular leak.
Cardiac function improvement30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsNYHA functional classification

Other

MeasureTime frameDescription
hemorrhage30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsRate of patients with hemorrhage during the trial.
acute kidney injury30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsRate of patients with acute kidney injury during the trial.
Product performance evaluationImmediate after procedureProduct Performance includes grip loading, emptying , delivery, release, retrace, development and retrieval performance of delivery catheter system. Every item measured by:1=good 2=average 3=poor.
Other TAVI related complications30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsRate of patients with Other TAVI related complications during the trial. Other TAVI related complications include conversion to surgery, accidental cardiopulmonary mechanical assistance, coronary occlusion, ventricular septal perforation, mitral valve damage or loss of function, pericardial tamponade, endocarditis, valvular thrombosis, valvular ectopic (displacement, embolization, erroneous release), etc.
Valvular function30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsValvular function include valve stenosis, valve regurgitation, valve function (such as opening area, pressure gradient), perivalvular leakage, etc. There is Echo standard in VARC II to apply for valvular function assessment.
Vascular Complications30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsVascular Complications
Operative complicationImmediately after procedureThe rate of operative complication
The incidence of major adverse cardiovascular and cerebrovascular events during the trial(MACCEs)30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsIncidence of MACCEs (mortality, stroke, myocardial infarction, and so on surgery, arrhythmias, conduction blocks) during the trial
Incidence of major adverse valve-related events (MAVREs) during the trial30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 yearsincluding prosthetic valve-related death, permanent cardiac pacemaker implantation, permanent cardiac defibrillator implantation, prosthetic valve embolism, prosthetic valve thrombosis, prosthetic valve dysfunction.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026