Brief summary

In this clinical trial, an un-controlled, repeated measures open design with within-subject comparison will be used to evaluate the effect of Naída Link M90 hearing aid and Naída CI M90 sound processor on sound perception. This design was shown to be successful in previous studies for the evaluation of sound coding strategies. Furthermore, a within-subject comparison decreases the variance in the results allowing for fewer subjects when the population that uses the investigational device is not large in general.

Interventions

DEVICENaída CI M90 Sound Processor (hearing aid and cochlea implant sound processor)

Speech perception measures, Hearing thresholds, Enjoyment rating, Sound identification, Subjective feedback

Sponsors

Advanced Bionics AG
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Intervention model description

comparision of different conditions with-in subject. (10 bimodal, 10 bilateral CI users)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* CI users with a CII, HiRes90K (Advantage) or HiRes Ultra implant system * Bilateral users: two implant systems * Bimodal users: hearing aid contralateral * Minimum of 18 years of age * Minimum of six months experience with their implant system * Minimum of six months experience with the Naída CI Q-Series sound processor * Ability to give feedback on sound quality * Speech intelligibility with the HSM sentence test in noise at 10 dB SNR \> 10% as obtained during previous visits in the clinical routine * Fluent in German language

Exclusion criteria

* Difficulties additional to hearing impairment that would interfere with the study procedures * Concurrent participation in other study * Pregnant and breast-feeding women

Design outcomes

Primary

MeasureTime frameDescription
Difference in speech perception in noise with AutoSense OS on Naída M hearing devices and AutoSound OS on the clinically available Naída Q hearing devices6 weeksDifference in speech reception threshold of 50% speech understanding which is the signal to noise ratio in Decibel \[dB\] to understand 50% of the target speech between AutoSense OS on Naída M hearing devices and AutoSound OS on the clinically available Naída Q hearing devices.

Secondary

MeasureTime frameDescription
Differences in speech perception in noise threshold measured in Decibel [dB]6 weeksDifferences are compared between AutoSense OS on Naída M hearing devices and the omnidirectional microphone setting on Naída Q hearing devices. Min and Max values are -10dB and +10dB, whereas the smalller the value the better
Differences in speech perception in quiet threshold measured in Decibel [dB]6 weeksDifferences are compared between AutoSense OS on Naída M hearing devices and AutoSound OS on Naída Q hearing devices and the omnidirectional microphone setting on Naída Q hearing devices. Min and Max values are -10dB and +10dB, whereas the smalller the value the better
Differences in mono/stereo identification measured in % correct6 weeksDifferences are compared between mono and stereo free-field presentation, mono and stereo streaming presentation, stereo free-field and stereo streaming presentation, mono free-field and mono streaming presentation, differences in music enjoyment ratings measured in rating score
Differences in speech understanding in noise measured in % correct6 weeksDifferences are compared between AutoZoomControl on Naída M hearing devices and the omnidirectional microphone setting on Naída Q hearing devices
Differences in music enjoyment ratings measured in rating score6 weeksDifferences are compared between * mono and stereo free-field presentation * mono and stereo streaming presentation * stereo free-field and stereo streaming presentation * mono free-field and mono streaming presentation