Skip to content

SmartCardia for the Detection of Myocardial Ischemia in Coronary Artery Disease

Clinical Use of the SmartCardia Wireless Recorder for the Detection of Myocardial Ischemia in the Setting of Coronary Artery Disease: a Single Arm, Prospective Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04810845
Acronym
Smartschemia
Enrollment
50
Registered
2021-03-23
Start date
2021-04-30
Completion date
2021-09-30
Last updated
2021-03-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myocardial Ischemia

Keywords

ischemia

Brief summary

Coronary artery disease and myocardial ischemia are among the leading causes of death and disability in the Westerns countries. Timely and accurate diagnosis of myocardial ischemia at the moment of symptom onset is crucial and often delayed. Portable smart medical devices nowadays offers the possibility of ubiquitous self multi-parametric monitoring. Application of such technologies to timely and autonomous detection of myocardial ischemia could be an effective strategy to an earlier and better treatment of symptomatic coronary artery disease. The primary objective is to assess the changes in recorded by the SmartCardia patch (respiratory rate, pulse transit time, heart rate and single ECG trace) during induced ischemia during elective coronary angioplasty procedures. The secondary objective is to asses whether myocardial ischemia can be predicted and quantified by changes in the parameters recorded by SmartCardia patch (respiratory rate, pulse transit time, heart rate and single ECG trace).

Detailed description

Coronary artery disease and myocardial ischemia are among the leading causes of death and disability in the Westerns countries. Timely and accurate diagnosis of myocardial ischemia at the moment of symptom onset is crucial and often delayed. Portable smart medical devices nowadays offers the possibility of ubiquitous self multi-parametric monitoring. Application of such technologies to timely and autonomous detection of myocardial ischemia could be an effective strategy to an earlier and better treatment of symptomatic coronary artery disease. The primary objective is to assess the changes in recorded by the SmartCardia patch (respiratory rate, pulse transit time, heart rate and single ECG trace) during induced ischemia during elective coronary angioplasty procedures. The secondary objective is to asses whether myocardial ischemia can be predicted and quantified by changes in the parameters recorded by SmartCardia patch (respiratory rate, pulse transit time, heart rate and single ECG trace). SmartWearable devices will be applied 30 minutes before coronary angiography (2/3 devices per-patients would be applied). Percutaneous coronary intervention will be conducted following a given protocol (not influencing patient's treatement): 1. Myocardial ischemia will be measured with the Fractional Flow Reserve (FFR) wire during stent expansion (total artery occlusion caused by balloon inflation). This will have no impact on patients' management as the wire will already have been inserted for the diagnostic procedure and will not have an impact on procedure duration. 2. Recording of a 6 leads electrocardiogram during the ischemia phase, which is anyway always available as part of our routine monitoring system. 3. Patients will systematically be asked for any chest pain or discomfort during ischemia (step which is anyway frequently done in standard procedures), to differentiate between clinical and subclinical ischemia. At the end of the procedure, the device will be kept during 30 supplementary minutes while the patient is on standard post percutaneous coronary intervention (PCI) surveillance, thus offering measurements during recovery from ischemia.

Interventions

DEVICEApplication of Class II A device SmartCardia

Application of SmartCardia monitor patch 30 minutes before coronary angiography (2/3 devices per-patients would be applied). Non invasive recording of single-lead ECG, respiratory rate, pulse transit time, heart rate would occur pre, during and post (30 minutes) primary angioplasty procedure

Sponsors

Centre Hospitalier Universitaire Vaudois
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* ≥18 years old patients * Known coronary artery disease * Admitted for elective coronary angiography with planned PCI * Informed consent signed

Exclusion criteria

* urgent procedure with possible ongoing ischemia before procedure (i.e. STEMI and NSTEMI in the acute phase) * Recent acute coronary syndrome (i.e. STEMI and/or NSTEMI \<48h or with persistent ST elevation) * Admission for revascularization of a total chronic occlusion * Known severe valvular disease * Decompensated heart-failure * Decompensated pulmonary condition (such as COPD) * Pregnant and breast-feeding women * Patients with prior CABG * Patients with severe renal failure (eGFR \< 30ml/mn) * Vulnerable patients (minors, participants incapable of judgment or participants under tutelage)

Design outcomes

Primary

MeasureTime frameDescription
Assessment of Ischemia detectionDuring Coronary Revascularisation procedureAssessment of whether myocardial ischemia induced differences would be recorded by the SmartCardia patch by estimating the effect size observed on each individual parameter recorded by the device for each patient, comparing the values measured on pre- and during-ischemia intervals.

Secondary

MeasureTime frameDescription
Assessment of ischemia severityDuring Coronary Revascularisation procedureEstablishment of dose-response curve between the recorded parameters by Smart-Cardia and the ischemia severity (based of distal coronary artery pressure)
Model description for coloration between ischemia severity and parameters recordedDuring Coronary Revascularisation procedureIntegration of multiple parameters into a more complex model to increase level of correlation between the recorded parameters and the severity of ischemia

Countries

Switzerland

Contacts

Primary ContactNiccolo' Maurizi, MD
niccolo.maurizi@chuv.ch0041 079 5568 981

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026