Custom Print Megnetic Levator Prosthesis Pilot Comparison

Status
Completed
Phases
Early Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04807855
Enrollment
16
Registered
2021-03-19
Start date
2019-04-01
Completion date
2020-03-31
Last updated
2021-03-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blepharoptosis

Keywords

Blepharoptosis

Brief summary

Study the device feasibility of non-surgical treatment for blepharoptosis (inability to open the eyelid) consisting of a biocompatible magnetic element adhered to the upper eyelid and a second magnet above the eye on a custom 3D-printed eyeglasses frame with a dial to provide adjustable magnetic force to open the eye while still allowing eye closure.

Detailed description

Extensive description of the study protocol is provided in the Research Strategy (R), but key components are summarized and justified here. This is a prospective, interventional, single-arm, single-group open label study. Because the primary objective of this study is to perform prototyping in the interest of developing and determining the feasibility of our novel approach, randomization to treatment or control is not necessary or appropriate at this stage. All participants will have ptosis and will be fitted with the experimental custom adjustable force MLP. Determining if the custom MLP is superior to the non-custom MLP is beyond the scope of this phase I SBIR project. The primary outcome is custom MLP fitting success defined as 8mm interpalpebral fissure size or greater, patient desire to engage in a 20-min trial, and comfort rated greater than 5 out of 10 after the 20 minute trial (all criteria must be met). These criteria may be met at any one visit in the prototyping process. Therefore, one prototype may fail but if subsequent prototypes succeed, the case will be rated as a success. Selection of the criteria was based on a desire to have both objective and subjective metrics. Eye opening of 8mm was selected because it is a functional amount of eye opening found to be useful to patients in prior studies (note that these patients do not have inferior lid malposition). We have used interpalpebral fissure as a primary outcome as opposed to Marginal Reflex Distance (distance from the corneal reflection to upper lid) in order to allow enrollment of bilateral and severe cases, and to provide a common outcome for both eye opening and closing on the blink. Desire to engage in a 20-minute trial was selected as a criteria because it provides some information on the patient's opinion of the device. Comfort greater than 5 out of 10 indicates better than neutral, and was selected as a minimum goal for success (median comfort in our prior study was 8 out of 10). The statistical analysis method for the primary outcome will be an exact binomial test of one proportion to determine which condition is met for more than half of patients. If the prototype approach is successful for greater than half of patients after 20 minutes of wear there will be a large enough sample for a phase II study to warrant continued development. Sample Size Calculation for primary outcome: With 10 subjects we will have 80% power to show that the success rate significantly exceeds 50% with a one-sided alpha=0.05 exact binomial test of one proportion when the success rate is 8/10 or greater, meaning 8 would have to succeed to reach significance. With 15 subjects the success rate would need to be 11 to reach significance.

Interventions

DEVICEThe cMLP device

There is only one medical device we are testing, so only one intervention.

Sponsors

Massachusetts Eye and Ear Infirmary
CollaboratorOTHER
Skelmet Inc
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
5 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Presence of Blepharoptosis for at least one eye, moderate cognitive function or better defined as greater than or equal to 18 out of 30 on a pre-screening of the Mini-Mental State Exam, age 5 or older. Sex - All. Gender Based - All.

Exclusion criteria

* Absence of Blepharoptosis. Age less than 5, Severe Cognitive impairment defined as Mini-mental score less than 18, behaviors consistent with delirium (combinations of disorientation, hallucinations, delusions, and incoherent speech), or lethargy. These individuals must be excluded since participation requires competent self-care, reliable responses and cooperation during fitting of the devices. Healthy Volunteers.

Design outcomes

Primary

MeasureTime frameDescription
Resting interpalpebral fissure sizeafter 20 minutes of wearInterpalpebral fissure is defined as the greatest distance between the upper and lower eye lid margins at the insertion point of the lashes. Resting is defined as point where the eyelid is maximally elevated.
Patient decision to participate in a 20-min trial with the prototype MLPafter 2 minutes of wearThis is a binary response measure (1 = yes I would like to participate or 0 = no I would not like to participate.
Comfort rating scaleafter 20 minutes of wearThis measure is a 10 point likert-type rating scale used to quantify the comfort of the MLP (1 poor comfort to 10 high comfort).

Secondary

MeasureTime frameDescription
Difference in the resting interpalpebral fissure size from highest to lowest magnetic force settingsafter 2 minutes of wearInterpalpebral fissure is defined as the greatest distance between the upper and lower eye lid margins at the insertion point of the lashes. Resting is defined as point where the eyelid is maximally elevated.
Interpalpebral fissure size at maximum blinkafter 2 minutes, 20 minutes, and 1-week of wearInterpalpebral fissure is defined as the greatest distance between the upper and lower eye lid margins at the insertion point of the lashes. Maximum blink is the point of smallest interpalpebral fissure (most closing).
Frequency and severity of adverse eventsafter 20 minutes and 1-week of wearThresholds for adverse events include eyelid skin erythema greater than grade II on the industry scale, grade II worsening in corneal staining on the NEI industry scale, and a greater than 2-line worsening in visual acuity in the treated eye.