Covid19, Lung Ultrasound, Pneumonia
Conditions
Brief summary
Lung ultrasonography (LUS) is also used in COVID 19 pneumonia for diagnostic and follow-up purposes.It has been demonstrated in different studies that it can be used for pathologies in pleural and lung tissue. LUS was applied by different researchers by dividing the lungs into 12 and 14 regions and the results were shared.
Detailed description
In our study, we aimed to determine the correlation between lung findings of COVID 19 pneumonia and thoracic tomography with the results of LUS applied to different numbers (12 versus 14) of areas.
Interventions
Application of 12 areas (2 posterior, 2 lateral, and 2 anterior)lung ultrasonography protocol using the convex ultrasound probe (2-6 MHz)
Application of 14 areas (3 posterior, 2 lateral, and 2 anterior) lung ultrasonography protocol using the convex ultrasound probe (2-6 MHz)
Sponsors
Study design
Masking description
The investigator was unaware of patient information such as medical history, PCR (polymerase chain reaction) test result, laboratory measurements, and CT scan results
Eligibility
Inclusion criteria
* 18 and 85 years old * Hospitalized in intensive care unit * PCR (polymerase chain reaction) tested * Thoracic CT applied
Exclusion criteria
* Previous lung operation * Thoracic wall disorder * Interstitial lung disease * Patients who did not consent to participate in the study
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Correlation between Thoracic CT imaging results and LUS results | 6 hours | Lung ultrasonography will be performed within 6 hours of the Thoracic CT. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Characteristics of lesions | 6 hours | Identifying the characteristics of the abnormal findings detected in Thoracic CT and LUS |
Countries
Turkey (Türkiye)