Skip to content

The Rescuer Fatigue During Cardiopulmonary Resuscitation in Manikin by Using Personal Protective Equipment.

The Impact of Rescuer Fatigue and Quality During Cardiopulmonary Resuscitation by Using Personal Protective Equipment. A Randomized Controlled Crossover Trial.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04802109
Enrollment
40
Registered
2021-03-17
Start date
2021-04-01
Completion date
2021-06-30
Last updated
2022-03-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Arrest

Keywords

personal protective equipment, rescuer fatigue, N-95, Powered Air-Purifying Respiratory

Brief summary

Background: High-quality cardiopulmonary resuscitation is the key to recovering patients with sudden cardiac death. However, when the environment is exposure to biologic hazard, the medical personnel need to use different personal protective equipment while doing CPR, and this difficulty is greatly increased. The research on this part is quite limited, and the results need to be further analyzed. Purpose: Compare the effects of CPR wearing different levels of personal protective equipment on CPR quality and rescue fatigue. Material & Methods: This study is designed as a prospective randomized crossover trial with an expected total of 40 volunteer participants, performed during 2021 April 1 to 2021 June 30. Each participant is required to perform a five-minute CPR in kneeling position using three different types of personal protective equipment. These three modes are Level D protective equipment with surgical mask, Level C protective equipment with N-95 mask, and Level-C protective equipment with Powered Air Purifying Respirator. Participants are physicians or nurses at the hospital. The participation are randomly assigned to the order of the three modes, and each mode can be rested for 120 minutes. Laerdal Skillreporter is used for CPR and quality measurement. The main results were effective chest compression ratio, correct chest depth ratio, correct chest recoil ratio and chest compression number per minute. The secondary results were personal blood pressure before and after the CPR, heartbeat, pulse oximeter, number of breaths, and subjective fatigue index (VAS 1 \ 100 points), Questionnaire for the opinion of wearing personal protective equipment and using the porta count test to test the N-95 face mask for its quantitative fitness factor before and during CPR, and infrared detector for qualitative fitness test.

Detailed description

Background: High-quality cardiopulmonary resuscitation is the key to recovering patients with sudden cardiac death. However, when the environment is exposure to biologic hazard, the medical personnel need to use different personal protective equipment while doing CPR, and this difficulty is greatly increased. The research on this part is quite limited, and the results need to be further analyzed. Purpose: Compare the effects of CPR wearing different levels of personal protective equipment on CPR quality and rescue fatigue. Material & Methods: This study is designed as a prospective randomized crossover trial with an expected total of 40 volunteer participants, performed during 2021 April 1 to 2021 June 30. Each participant is required to perform a five-minute CPR in kneeling position using three different types of personal protective equipment. These three modes are Level D protective equipment with surgical mask, Level C protective equipment with N-95 mask, and Level-C protective equipment with Powered Air Purifying Respirator. Participants are physicians or nurses at the hospital. The participation are randomly assigned to the order of the three modes, and each mode can be rested for 120 minutes. Laerdal Skillreporter is used for CPR and quality measurement. The main results were effective chest compression ratio, correct chest depth ratio, correct chest recoil ratio and chest compression number per minute. The secondary results were personal blood pressure before and after the CPR, heartbeat, pulse oximeter, number of breaths, and subjective fatigue index (VAS 1 \ 100 points), Questionnaire for the opinion of wearing personal protective equipment and using the porta count test to test the N-95 face mask for its quantitative fitness factor before and during CPR, and infrared detector for qualitative fitness test. Inclusion criteria: physicians and nurses from An Nan Hospital, with more than one year of work experience, possessing ACLS or BLS certificate, regardless of gender, height and weight. Exclusion criteria: back pain in the past, spine surgery, sciatica, coronary heart disease, and lung diseases such as asthma or chronic obstructive pulmonary disease. Pregnant women need to be excluded. Statistic Method On the basis of our previous study (Foo NP,et al.Rescuer fatigue and cardiopulmonary resuscitation positions: A randomized controlled crossover trial. Resuscitation. 2010;81(5):579-584). we estimated that with a level of 0.05, a power of 80%, and an effect size of 0.6, a sample size of 18 participants would be sufficient for evaluating the primary outcome. We applied the Shapiro-Wilk test to evaluate the normality of the distribution of data. Then, we applied ANOVA for repeat measures and the Bonferroni procedure to evaluate the differences among and between different positions if the data fit the Gaussian distribution, and the Friedman test and Wilcoxon signed rank test if the data did not fit the Gaussian distribution. All the statistical tests were performed at the two-tailed level of significance at 0.05, and all statistical analyses were performed using SPSS for Windows, Version 17.0 (SPSS Inc., Chicago, U.S.A.).

Interventions

DEVICEwearing level D personal protective equipment

rubber gloves + surgical face mask + general isolation clothing

DEVICEwearing Level C personal protective equipment with N-95

C-level protective clothing+ N95 mask + disposable protective clothing (Ten Quin Medial Apparel) + foot cover + rubber gloves + mask + general isolation clothing

DEVICEwearing Level C personal protective equipment with Powered Air-Purifying Respiratory

C-level protective clothing+ N95 mask + disposable protective clothing (Ten Quin Medial Apparel) + foot cover + rubber gloves + mask + general isolation clothing+Powered Air-Purifying Respiratory

Sponsors

An-Nan Hospital, China Medical University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
SINGLE (Outcomes Assessor)

Masking description

It is impossible to masking the participant, care provider during the CPR study.

Intervention model description

This study is designed as a prospective randomized crossover trial . Each participant is required to perform a five-minute CPR in kneeling position using three different types of personal protective equipment. After each round of CPR for 5 minutes, the participants can rest for two hours before the next round of CPR with different type of personal protective equipment

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* Physicians and nurses at An Nan Hospital, with more than one year of work experience, with Advanced cardiac life support or basic life support certificate

Exclusion criteria

* back pain in the past, spine surgery, sciatica, coronary heart disease, and lung diseases such as asthma or chronic obstructive pulmonary disease. Pregnant women are also excluded.

Design outcomes

Primary

MeasureTime frameDescription
effective chest compression ratio5 minuteseach chest compression that deep greater than 5 cm, around 100\ 120 times per minutes and recoil during each chest compression

Secondary

MeasureTime frameDescription
quantitative fitness factor of face mask5 minutesusing porta count to detect the quantitative fitness factor of face mask. data from 0\ 200, if \>=100 remain qualified outcome

Countries

Taiwan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 7, 2026