Skip to content

Clinical Evaluation of the Free Margin Cusp Sizer (CALIBRATE)

CALIBRATE TRIAL: a Prospective, Single Arm Investigational Clinical Trial Evaluating Safety and Performance of the Free Margin Cusp Sizer During Aortic Valve Repair Surgery

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04797572
Acronym
CALIBRATE
Enrollment
120
Registered
2021-03-15
Start date
2021-03-22
Completion date
2027-12-30
Last updated
2025-05-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Root Aneurysm, Aortic Valve Regurgitation

Keywords

aortic valve repair, Valve sparing surgery, Trileaflet aortic valve

Brief summary

The objective of this study is to investigate safety and performance of the Free Margin Cusp sizer. The device will be used during aortic valve repair and sparing procedures as a caliper to measure the aortic valve free margin length at different stages of the procedure. The patient will be followed for one year clinically (at 1, 2, 6 and 12 months) and by echocardiography (at 6 and 12 months) to assess aortic valve function.

Detailed description

Goal of the study : The objective of this study is to study the safety and reliability of a new surgical instrument, the Free Margin Cusp Sizer (patented device). The measuring instrument will be used during aortic valve repair procedures to measure the length of the free edge of the aortic cusps. State of the art : Currently, aortic valve repair is done by visual estimation and requires a great level of experience from the surgeon. We proposed to develop an objective cusp repair technique based on the measurement of the free edge by a dedicated sizer. The measuring instrument will give the objective difference in millimeters between the normal cusp and the one with prolapse. This will then be quantitatively plicatured to correct its excess length. This new technique will allow less experienced surgeons or those in the process of learning objective guidance of valve repair. The objective measure of the free edge length may also orient the sizing of the Dacron graft used for valve sparing root replacement. Study evaluation criteria: * Hospital mortality (mortality at 30 days), MACCE at one year: mortality, cerebrovascular accident or transient ischemic attack, major hemorrhage, cardiac reoperation * Echocardiographic results at discharge from hospital and at 6 months or one year Material and methods: * Single-center, prospective, non-randomized study * Patient source: Patients operated for aortic valve repair or aortic valve sparing surgery at Cliniques Universitaires Saint-Luc (CUSL), Brussels * Number of patients to be included: 120, study duration: 6,5 years, inclusion period: 5,5 years, follow-up: 1 year * Inclusion criteria: patient with a tricuspid aortic valve operated electively for aortic valve insufficiency or dilation of the ascending aorta * Exclusion criteria: acute aortic dissection, diffuse aortic valve calcification, endocarditis, bicuspide, unicuspid or quadricuspid aortic valve, patient under 18 and over 80 Data acquisition and patient follow-up: The examinations carried out within the framework of this study are the same as those carried out routinely during the preoperative cardiac assessment and clinical follow-up after aortic valve repair: * Preoperative cardiovascular examination including TTE (transthoracic ultrasound) / TEE (transesophageal ultrasound) * Intraoperative TEE pre and post aortic valve repair * TTE at discharge * TTE between 6 months and one year postoperatively * 1 month post-operative consultation (outpatient surgery) * Consultation 1 to 2 months postoperative (referring cardiologist) * Consultation 6-12 months postoperative (referring cardiologist) (if necessary, phone contact with the patient at 12-14 months)

Interventions

DEVICEFree Margin Cusp Sizer

The free margin cusp sizer will be used during aortic valve repair and sparing procedures as a caliper to measure the aortic valve free margin length.

Sponsors

Cliniques universitaires Saint-Luc- Université Catholique de Louvain
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patients with Tricuspid Aortic Valve (TAV) operated electively for aortic valve regurgitation and or ascending aorta dilatation.

Exclusion criteria

* Acute aortic dissection; * Diffuse aortic valve calcification; * AV endocarditis; * Bicuspid, unicuspid or quadricuspid aortic valves; * Patients under the age of 18 years; * Patients above the age of 80 years.

Design outcomes

Primary

MeasureTime frameDescription
Intraoperative aortic valve (AV) damage30 daysAortic valve damage caused by the cusp sizer (cusp tear or perforation), rate of conversion from AV repair to AV replacement due to the use of the cusp sizer
Hospital mortality30 daysPatient Survival status at 30 days after surgery
Major adverse cardiac and cerebrovascular events (MACCE)one yearMortality, stroke or transient ischemic attack, major bleeding, cardiac reintervention
Aortic valve functionOne yearAortic valve regurgitation and transvalvular gradient by transthoracic echocardiography

Secondary

MeasureTime frameDescription
Pre-repair free margin lengthIntraoperativeLength of the 3 leaflets free margin before aortic valve repair

Countries

Belgium

Contacts

Primary ContactLaurent de Kerchove, MD, PhD
laurent.dekerchove@uclouvain.be+32 2 764 41 51
Backup ContactCorinne Coulon
corinne.coulon@uclouvain.be+32 2 764 6108

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026