A Validation Study of the Lab Clasp Device: A Point of Care Sepsis Risk Monitor

A Validation Study of the Lab Clasp Device: A Point of Care Sepsis Risk Monitor

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04796285
Enrollment
6
Registered
2021-03-12
Start date
2022-08-01
Completion date
2026-12-01
Last updated
2026-07-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Infectious Disease, Lactate Blood Increase, Sepsis, Sepsis Bacterial

Keywords

point of care, sepsis, interstitial fluid, lactate

Brief summary

The overall purpose of this study is to demonstrate the usability of a clinical-grade device in the form of a finger clasp similar to a pulse oximeter for monitoring lactate values, by comparing its performance in reading interstitial fluid lactate values against a known clinical standard in the form of venous lactate levels. Serum lactate measurements are used clinically as a measure of end-organ dysfunction and physiologic stress. Changes in lactate may indicate worsening infection in the setting of sepsis, drug toxicity for certain xenobiotics, or exercise tolerance in exercise physiology. Serum lactate cutoffs have been developed for various disease states and trigger a variety of medical decisions directed at managing the course of the disease. A common theme in the application of lactate measurements to understanding changes in physiology is the need to obtain venous blood to determine lactate. While point-of-care assays have been developed that improve the processing speed, there continues to be a need to obtain fingerstick blood or in most cases, venous blood. Obtaining venous blood for serum lactate requires an individual with phlebotomy skills, the processing capabilities of a laboratory to determine lactate concentrations, or the availability of point of care technology. An alternative method to measure lactate is to sample interstitial fluid which surrounds cells and tissues in the body. Obtaining interstitial fluid is potentially less invasive without the need for repeat phlebotomy or the presence of an indwelling intravenous catheter which can become complicated by infection. The analysis of interstitial fluid for glucose has been validated and is clinically utilized in continuous glucose monitors in individuals with diabetes. In this investigation, the investigators will utilize a novel device, the Lab Clasp to obtain interstitial fluid in a noninvasive method. The Lab Clasp is manufactured to resemble a finger pulse oximeter with additional onboard microfluidics channels that obtain a lactate concentration from interstitial fluid. This streamlined process of obtaining the point of care lactate measurements on demand allows for tasks like serial lactate measurements to be accomplished on a reliable schedule with less workload for nursing staff typically required to draw venous blood. Additionally, the portable and noninvasive nature of the Lab Clasp system may render it usable in facilities that lack skilled staff necessary to perform phlebotomy.

Interventions

DEVICELab Clasp

Finger-based interstitial fluid assessment device

Sponsors

Brigham and Women's Hospital
Lead SponsorOTHER
Cambridge Medical Technologies, LLC
CollaboratorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Are 18 years or older 2. In general good health, evidenced by no unstable medical problems (no medication changes in the past 3 months) 3. Have no known skin allergy to the components of the Lab Clasp 4. Willing to comply with all study procedures including providing venous blood samples at the CCI 5. Are English speaking 6. Provide consent to participate in the study

Exclusion criteria

1. Individuals \<18 years old 2. General frailty of health 3. Prohibitively poor vascular access 4. History of malignancy or active malignancy 5. History of cardiac illness 6. History of HIV on antiretrovirals 7. History of alcohol abuse 8. History of uncontrolled psychiatric illness 9. Recent hospitalization within the past 30 days 10. History of vaping, propylene glycol use 11. History of statin use 12. Non-English speaking 13. Pregnant women, children, vulnerable populations 14. Investigator discretion for suspicion of poor study compliance

Design outcomes

Primary

MeasureTime frameDescription
Comparison of average difference lactate readings between Lab Clasp and laboratory reference values.150 minutesThe primary outcome measure will be the average difference in lactate values between the Lab Clasp device and the reference (laboratory venous lactate) in healthy volunteers. We will obtain multiple (nine timepoints in total) investigational-reference measurement pairs in each subject (150 minutes total) and will average the difference over all pairs from all subjects.

Secondary

MeasureTime frameDescription
Measurement of participant experience150 minutesWe will give each participant a questionnaire when they finish their visit and will ask for their experience (Likert-type scale, 1-5)

Countries

United States

Contacts

PRINCIPAL_INVESTIGATORGuruprasad Jambaulikar, MBBS, MPH

Brigham and Women's Hospital

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 17, 2026