Skip to content

Speckle Tracking Echocardiography Analysis of Left Ventricular Myocardium After Percutaneous Intramyocardial Septal Radiofrequency Ablation for Hypertrophic Obstructive Cardiomyopathy

Left Ventricular Systolic Function After Percutaneous Intramyocardial Septal Radiofrequency Ablation for Hypertrophic Obstructive Cardiomyopathy: a Study Focused on Speckle Tracking Echocardiography

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04777188
Enrollment
70
Registered
2021-03-02
Start date
2016-10-22
Completion date
2019-07-09
Last updated
2021-03-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypertrophic Obstructive Cardiomyopathy

Keywords

Cardiomyopathy, hypertrophic, Speckle tracking echocardiography

Brief summary

Objective to investigate the left ventricular (LV) systolic function by speckle tracking echocardiography before and after percutaneous intramyocardial septal radiofrequency ablation for hypertrophic obstructive cardiomyopathy (HOCM). Percutaneous intramyocardial septal radiofrequency ablation (named Liwen Procedure) is a safe and effective treatment approach for HOCM and results in sustained improvement in exercise capacity and persistent in reducing left ventricle outflow tract (LVOT) gradient. However, the systolic function of the myocardial after Liwen procedure in HOCM patients is not well exploration and research. Strain evaluation using speckle tracking echocardiography is an excellent tool for assessing regional and global LV functions. In this study, the investigators aimed to characterize regional and global strain using speckle tracking echocardiography to assess LV radial, circumferential and longitudinal systolic myocardial function in patients with HOCM before and after Liwen procedure.

Interventions

PROCEDUREPercutaneous Intramyocardial Septal Radiofrequency Ablation for hypertrophic obstructive cardiomyopathy

Under transthoracic echocardiography (TTE) guidance, the puncture site is positioned at the apex. A guiding line is applied along the septal long axis and the radiofrequency ablation electrode needle(17G, Cool-tip™ RF Ablation System and Switching Controller;Medtronic, Minneapolis, MN, USA) pierced towards the hypertrophic anterior interventricular septum (AIVS) 8-10 mm from the subaortic valve. Each ablation lasts for up to 12 min and the ablation power is gradually increased from 30-40W. Then, the ablation needle is withdrawn 10 mm to prepare for the next application. Overall, 3-4 applications are performed in each patient. The ablation creates an area of thermal coagulative myocardial necrosis that appears as a hyperechogenic reflection detected by TTE. If deemed necessary, we repeat the procedure at the posterior interventricular septum (PIVS).

Sponsors

Xijing Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Patients with symptoms that limit daily activities (New York Heart Association functional class \>II, exercise-induced syncope) despite adequate medical treatment or when medical treatment is not tolerated 2. Patients with a peak LVOT gradient≥50 mm Hg

Exclusion criteria

1. Those with a peak instantaneous Doppler LVOT gradient of \<50 mm Hg 2. Those with an indication for septal reduction therapy and other lesions requiring surgical intervention (e.g., mitral valve repair/replacement and papillary muscle intervention) 3. Those with end-stage heart failure;and those the echocardialology image quality is not clear enough for strain analysis.

Design outcomes

Primary

MeasureTime frameDescription
Left ventricular systolic function before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation1 yearThe left ventricular(LV) systolic function was analyzed by Tomtec Workstation with related software. LV was automatically divided into 16 segments using standard segmentation. The following LV parameters were automatically calculated by the software. The 3D strain indexes derived included ,LV peak systolic global longitudinal strain (GLS,percent), LV peak systolic global radial strain (GRS,percent), LV peak systolic global circumferential strain (GCS,percent)

Secondary

MeasureTime frameDescription
left ventricular outflow tract gradient before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation1 yearThe results were obtained by continuous Doppler echocardiography (mmHg)
Interventricular septal thickness before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation1 yearThe results were obtained by echocardiography , the unit of mm

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 11, 2026