Skip to content

Different Resectoscopes Effects to Optic Nerve Sheath Diameter

The Effect of Bipolar and Monopolar Resectoscope Use on Optic Nerve Diameter in Transurethral Resection Procedures Under Spinal Anesthesia

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04765397
Enrollment
80
Registered
2021-02-21
Start date
2018-07-20
Completion date
2019-03-15
Last updated
2021-02-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Optic Nerve Sheath Diameter

Keywords

Monopolar Resectoscope, Bipolar Resectoscope

Brief summary

In this study, in patients with benign prostatic hypertrophy, monopolar and transurethral prostate using bipolar techniques in resection; serum electrolytes in the perioperative period, osmolarity can occur in hemodynamic parameters the effect of changes on optic nerve diameter by ultrasonography.

Detailed description

This study is for TURP operation for Benign Prostate Hypertrophy patients. When patient comes to the operating room, routine preparations will be made. Haemodynamic parameters and over-the-eye with Optic nerve diameter will be checked with ultrasound before and 10 minutes after spinal anesthesia. Monopolar for patients according to the preference of the surgical team resectoscope technique or bipolar resectoscope technique will be applied. During the operation Blood pressure, pulse minute the number of irrigation solutions used and the amount of intravenously administered serum, operation time will be saved. Optic nerve sheath diameter after the operation would be checked again. intraoperative and postoperative complications in the waking room (respiratory distress, hypotension, hypertension, bradycardia, tachycardia, vomiting, headache, restlessness, seizure, arrhythmia, vision disorder) will be recorded.

Interventions

PROCEDUREEffect of different resectoscope fluids on optic nerve diameter measured by ultrasound

During the operation Blood pressure, pulse minute the number of irrigation solutions used, and intravenous serum amounts, operation time will be saved. If there is an abnormal parameters or increased optic nerve sheath surgical team will be informed.

Sponsors

Bursa Yuksek Ihtisas Training and Research Hospital
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

According to the resectoscopes used during the operation, patients will be divided into 2 groups as Monopolar one (Group M) and Bipolar one (Group B).

Eligibility

Sex/Gender
ALL
Age
50 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* Ages 50-80 * ASA I-II * Planned TUR-P operation

Exclusion criteria

* Heart or respiratory failure * Koagülation diathesis * Eyedisease related patients

Design outcomes

Primary

MeasureTime frameDescription
optic nerve sheath diameter(mm)operation time 3 hoursA linear 10-5 MHz ultrasound probe (GE Healthcare Logiqe Series) was held on the upper eyelid over the gel carefully. Part of the optical nerve that enters the orbital globe was monitorized in the 2D mode without exerting much pressure. Diameter of the optic nerve sheath was measured 3 mm behind the optic disk using an electronic caliper after the right contrast was found between the retrobulber echogenic fatty tissue and the vertical hypoechogenic band

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026