Learning Curves of Gastric Ultrasound for Novel

The Feasibility of Ultrasound for the Qualitative Assessment of Gastric Content, and Determine the Reliability of This Novel Tool in Gastric Volume Measurements When Performed by Novice Gastric Sonographers

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04760106
Enrollment
50
Registered
2021-02-18
Start date
2019-01-15
Completion date
2021-03-31
Last updated
2021-02-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Gastric Ultrasound, Learning Curve, Novel in Gastric Ultrasound

Keywords

Gastric ultrasound, Learning curve, Accuracy, Reliability, Novel in gastric ultrasound

Brief summary

Various studies have shown that gastric sonography can reliably provide information on both qualitative (nature of content) and quantitative (volume) aspects of gastric content. A recent study has suggested that a minimum of 33 scans is needed to achieve a 95% success rate in the qualitative assessment of gastric ultrasound. However, as the risk and severity of aspiration are also influenced by gastric volume, further study concerning quantitative assessment is warranted.

Detailed description

This study are conducted to affirm the feasibility of ultrasound for the qualitative assessment of gastric content, and determine the reliability of this novel tool in gastric volume measurements when performed by novice gastric sonographers. Two novels in gastric ultrasound learn from online materials, including educational videos and picture library through www.gastricultrasound.org and www.usra.ca. 1-hour lecture with discussion and 1-hour interactive hands-on with expert in gastric ultrasound. Then the novels were tested for the accuracy and reliability of their skills from 50 volunteers gastric ultrasound assessment.

Interventions

DIAGNOSTIC_TESTgastric ultrasound

For the qualitative assessment, every participant was scanned once by both examiners. Each scan session lasted no longer than 5 minutes to mitigate the confounding effect of gastric emptying time. For the quantitative assessment, the participants were put in a right lateral decubitus position and the antral cross-sectional area (CSA) is measured in the sagittal plane.

Sponsors

Mahidol University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* age between 18 to 70 years old with an American Society of Anesthesiologist physical status class I to II

Exclusion criteria

* BMI \> 40 kg/m2; pregnancy; diabetes mellitus; a history of upper gastrointestinal tract disease (including hiatal hernia and gastric tumors); and previous surgical procedures on the esophagus, stomach, or upper abdomen.

Design outcomes

Primary

MeasureTime frameDescription
The accuracy of qualitative ultrasound assessment of gastric content in novel gastric sonographers3 monthsNumber of volunteers which novel gastric sonographers are correct to identify whether is empty, fluid or solid (percentage)

Secondary

MeasureTime frameDescription
An interrater reliability of the quantitative ultrasound assessment of the gastric volume3 monthsUsing the result of cross sectional area from both novel gastric sonographers

Countries

Thailand