Skip to content

Modelling in the Quantitative Analysis of Brain PET Scans in Patients With Alzheimer's Disease

Interest of PFS Modelling in the Quantitative Analysis of Brain PET Scans in Patients With Alzheimer's Disease Acquired on a Numerical System

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04718207
Acronym
PET-SF
Enrollment
25
Registered
2021-01-22
Start date
2021-02-01
Completion date
2022-02-01
Last updated
2022-08-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patients With Alzheimer's Disease

Keywords

Alzheimer disease, PSF modelisation, quantitative analyze

Brief summary

PET/CT scans with 18F-FDG can be carried out for the detection of neurodegenerative diseases with hypometabolisms characteristic of the pathologies sought. The diagnosis is given by the clinician after a visual analysis of the data. To complete the diagnosis, a semi-quantitative analysis of the images is recommended (European recommendations) in addition to the visual analysis.

Detailed description

PET/CT scans with 18F-FDG can be carried out for the detection of neurodegenerative diseases with hypometabolisms characteristic of the pathologies sought. The diagnosis is given by the clinician after a visual analysis of the data. To complete the diagnosis, a semi-quantitative analysis of the images is recommended (European recommendations) in addition to the visual analysis. PET technology is improving from year to year thanks to the arrival of a new PET technology called digital. In addition, correction methods have been developed to improve PET images and thus improve the detection of different pathologies in PET. The PSF (Point Spread Function) tool enables partial volume effects to be corrected. The PSF consists of correcting the impulse response of the system, and allows a visual improvement of the images. Currently not recommended in brain PET/CT reconstructions, it remains to be evaluated for the quantitative analysis of acquisitions.

Interventions

DEVICEBrain positron emission tomopgraphy (PET) - scan

Patients who performed brain PET/CT scans in the nuclear medicine department from December 2017 to December 2020.

Sponsors

Central Hospital, Nancy, France
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Brain PET/CT scans at 18F-FDG of patients with Alzheimer's disease carried out in the nuclear medicine department of the Nancy-Brabois University Hospital since December 2017 on digital PET devices.

Exclusion criteria

* Patients who have expressed their opposition to the use of their data (poster in the service).

Design outcomes

Primary

MeasureTime frameDescription
The results obtained in quantitative analysis with and without PSF modelling of PET brain scans of patients with Alzheimer's disease acquired on PET / CT scan6 monthsComparison of the volumes detected by the quantitative analysis with the SPM (statistical parametric Mapping) software of brain PET scans of patients with Alzheimer's disease with and without FSP modelling.

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026