Skip to content

Investigation of Nickel Sensitization After Percutaneous Implantation of Patent Foramen Ovale Occluder

Investigation of Nickel Sensitization After Percutaneous Implantation of Patent Foramen Ovale Occluder; a RandomizEd Trial.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04713683
Acronym
INSPIRE
Enrollment
96
Registered
2021-01-19
Start date
2020-12-10
Completion date
2024-12-01
Last updated
2025-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dermatitis Contact Irritant, Foramen Ovale, Patent, Metal Allergy, Nickel Sensitivity

Keywords

patent foramen ovale, percutaneous pfo closure, Nickel Hypersensitivity, Nickel Sensitisation, device syndrome, skin patch tests

Brief summary

Percutaneous PFO closure has been established as a first-line therapy for preventing recurrent strokes in selected patients. The devices used for the specific purpose contain and release nickel, which is considered as the most allergen metal in nature. Skin patch tests are considered as gold-standard for documenting nickel allergy. While the allergic contact dermatitis induced by nickel is well described, literature is inadequate on explaining the effect of nickel release on the clinical manifestations of patients implanted with such devices. Our prospective, randomized, blinded trial will try to investigate the above by performing nickel skin patch tests to all patients, 14 days before and 90 days after the implantation. During follow-up, clinical manifestations and transthoracic echocardiographic findings will be evaluated and associated with patch skin tests.

Detailed description

Percutaneous PFO closure has been established as a first-line therapy for preventing recurrent strokes, after embolic stroke of unknown source (ESUS) and a patent foramen ovale. The PFO closure is achieved by the implantation of suitable devices, which occlude the shunt between the two atria and prevent the creation and detachment of thrombi. Until today, there are two devices approved by FDA for the specific purpose; Amplatzer PFO Occluder and Gore Cardioform Septal Occluder. Despite the architectonic differences between these devices, the main material of both is nitinol, an alloy of nickel and titanium. While titanium is an extremely rare allergen, nickel is considered as one of the most common allergens and the most frequent metal allergen in nature, with a prevalence about 20%. The main clinical expression of nickel hypersensitivity is allergic contact dermatitis, but cases with systemic allergic reaction have been described as well. It has been observed that nickel is released by the implanted devices and circulates through bloodstream, having the potential to cause systemic clinical picture. Device syndrome includes signs and symptoms (i.e. palpitations, dyspnea, chest pain, rash, etc.), which are appeared after the device placement and are associated with hypersensitivity reaction. The existing literature is considered as inadequate for explaining the effect of nickel release in the patients implanted with an occluder. The aim of our study is to evaluate whether patients with nickel hypersensitivity have an increased risk of adverse events following PFO closure, to assess the potential influence of device selection, and to evaluate potential sensitization or desensitization in patients without or with pre-existing nickel allergy, respectively. Nickel hypersensitivity was assessed using skin patch testing prior to the procedure. The primary endpoint was device syndrome, a composite of patient-reported symptoms (chest pain, palpitations, migraines, dyspnea, and rash). Secondary endpoints included arrhythmias, bleeding, stroke, and all-cause mortality.

Interventions

Patients with well-documented embolic stroke of unknown source (ESUS) and a patent foramen ovale (PFO) are indicated for percutaneous closure of PFO. The intervention is performed through the right femoral vein. The interventional cardiologist introduces the sheath and advances the device via inferior vena cava to right atrium. Then, the catheter is passed through the PFO, the device is deployed and the occlusion is achieved. The procedure is performed under fluoroscopy guidance with or without transesophageal echocardiography guidance.

Sponsors

National and Kapodistrian University of Athens
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
DOUBLE (Investigator, Outcomes Assessor)

Masking description

The dermatologist will be blinded regarding the device implanted in the patients. The interventional cardiologist will be blinded regarding the results of skin tests. The outcomes assessor will be blinded for both skin patch tests and the implanted device of each participant.

Eligibility

Sex/Gender
ALL
Age
14 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age: at least 14 years old * Well-documented indication for percutaneous PFO closure

Exclusion criteria

* Corticosteroid treatment * Patient's refusal to participation

Design outcomes

Primary

MeasureTime frameDescription
Device syndrome, a composite endpoint consisting of patient-reported new-onset chest pain, palpitations, new-onset or worsening migraines, dyspnea, and rashThe first 90 days after the procedureClinical signs and symptoms during the first 90 days after the procedure will be evaluated through a questionnaire.

Secondary

MeasureTime frameDescription
The nickel patch tests' results change after Gore Device implantationThe first 90 days after the procedureInvestigating the number of patients received Gore device, who developed nickel sensitization.
Residual interatrial leakage90 days after the procedureEvaluation of residual interatrial leakage, by performing transthoracic echocardiography
Rest allergens skin patch test results' change90 days after the procedureThe possible change (either as continuous or dichotomous outcome) of rest allergen skin patch test, after the device implantation
Nickel patch test results' change90 days after the procedureThe possible change (either as continuous or dichotomous outcome) of nickel skin patch test, after the device implantation
The nickel patch tests' results change after Amplatzer Device implantationThe first 90 days after the procedureInvestigating the number of patients received Amplatzer device, who developed nickel sensitization.
palpitations90 days after the procedureas described by the patients
new-onset or worsening migraines90 days after the procedureas described by the patients
dyspnea90 days after the procedureas described by the patients
Atrial arrhythmias90 days after the procedureas described by the patients
patient-reported new-onset chest pain90 days after the procedurepatient-reported new-onset chest pain

Countries

Greece

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026