Adenoma, Colorectal Cancer
Conditions
Keywords
Adenoma, Colorectal Cancer
Brief summary
The study is intended to compare the detection rate obtained by performing G-EYE® high definition colonoscopy vs. the detection rate obtained by performing ECV high definition colonoscopy.
Detailed description
This is a multicenter, two-arm, randomized, open-label study intended to compare the detection rate obtained by performing G-EYE® high definition colonoscopy vs. the detection rate obtained by performing ECV high definition colonoscopy.
Interventions
ENDOCUFF VISION® is a disposable cap placed on the tip of a standard colonoscope, intended to flatten colonic folds and assist in controlling the colonoscope's field of view and tip positioning
The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning
Sponsors
Study design
Intervention model description
Subjects will be randomized to one of two groups - ECV colonoscopy or G-EYE® colonoscopy
Eligibility
Inclusion criteria
1. Screening and surveillance population for Adenoma and CRC. 2. The patient must understand and sign a written informed consent for the procedure.
Exclusion criteria
1. Subjects with inflammatory bowel disease; 2. Subjects with a personal history of hereditary polyposis syndrome; 3. Subjects with suspected chronic stricture potentially precluding complete colonoscopy; 4. Subjects with diverticulitis or toxic megacolon; 5. Subjects with prior colonic surgery (exclusion appendectomy) 6. Subjects with a history of radiation therapy to abdomen or pelvis; 7. Pregnant or lactating female subjects; 8. Subjects who are currently enrolled in another clinical investigation. 9. Subjects with current oral or parenteral use of anticoagulants, not considered eligible by the investigator. 10. Subjects with recent (within the last 3 mounts) coronary ischemia or CVA (stroke) 11. Any patient condition deemed too risky for the study by the investigator
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Comparison between adenoma detection rate of G-EYE® colonoscopy and EndoCuff Vision® | June 2021 | G-EYE® colonoscopy adenoma detection rate will be compared to the adenoma detection rate of EndoCuff Vision® colonoscopy. The primary performance measure is the adenoma detection rate (ADR), which is defined as the percentage of subjects with at least one adenoma found, in each of the study groups. |
Countries
Germany, United States