To Evaluate the Safety and Clinical Performance of the ARCHIMEDES Biodegradable Biliary and Pancreatic Stent

A PROSPECTIVE, MULTI-CENTER, SINGLE-ARM, POST MARKET OBSERVATIONAL STUDY TO EVALUATE THE SAFETY AND CLINICAL PERFORMANCE OF THE ARCHIMEDES BIODEGRADABLE BILIARY AND PANCREATIC STENT

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04708288
Acronym
Registry
Enrollment
198
Registered
2021-01-13
Start date
2020-10-03
Completion date
2027-12-31
Last updated
2026-06-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obstructed Biliary and Pancreatic Duct

Brief summary

Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Stents are typically made from polymeric materials including Polylactic Acid (PLA), Polyglycolide (PGA), Polydioxanone (PDO), Polyethyleneglycol (PEG), Polycaprolactone (PCL), etc., which have been cleared or approved by the FDA and CE-marked as drug carriers, sutures, and bone fixatives. The material is degraded by hydrolysis in, e.g., lactic acid, which is removed from the body by normal metabolic pathways. In the field of gastroenterology, these stents were first introduced in patients with an esophageal stenosis with encouraging results, although esophageal hyperplasia was a frequently encountered complication. For biliary applications, biodegradable stents have been evaluated in several in-vitro and animal studies that demonstrated that the stents were safe and well tolerated. These stents provided an adequate radial force and resulted in complete stricture resolution within several months. The stents did not show any signs of biliary hyperplasia or integration in the epithelium. Moreover, they seem to have a self-clearing effect on attached biofilm as the outer layer sloughs during the degradation process similarly to the exfoliation of human skin. Also, the stent could be removed from the bile duct, thus offering the possibility of extraction if necessary at various times after implantation. In 2010, Petryl was the first to use a biodegradable stent in the human bile duct. A stent was successfully placed using percutaneous transhepatic cholangiograpy in two patients with a postsurgical intrahepatic biliary stricture. Transient cholangitis was the only complication encountered and during the two years of follow-up, the bile duct remained patent. Later, Mauri et al. presented in 2013 and 2016 results of a 107 patient study on a polydioxanone biodegradable biliary stent. The results have been published in the Journal of the European Society of Radiology. The authors concluded that percutaneous placement of a biodegradable biliary stent is a feasible and safe strategy to treat benign biliary strictures refractory to standard bilioplasty, with promising results in the mid-term period. Prior to this study, the ARCHIMEDES device was assessed in the ARCHIMEDES Investigational study which has completed enrolment with 53 patients included, and the results are not yet published. In this study approximately half the stents were deployed in the bile duct (53%) and half in the pancreatic duct. All 53 patients have either completed, exited, or no longer have the study device. No patient remains in the study with a stent in place during the time of the last patient follow-ups. The study concluded without any device-related SAE. Bilirubin was reduced by 25.6%, which exceeded the \>20% clinical success criterion, quality of life score improved from 3.7 to 7.9, procedural success was rated 1.4 (good to excellent), and technical success was achieved in all 53 patients. Data from the ARCHIMEDES Investigational study was used for CE Mark approval, which was obtained in June 2018.

Interventions

DEVICEARCHIMEDES Biodegradable Biliary and Pancreatic Stent

Patients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine clinical practice

Sponsors

QualiMed Innovative Medizinprodukte GmbH
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient eligible for implantation of a pancreatic or billiary stent prior to participate in the study and according to current guidelines * Patient has provided a signed and dated informed consent (according to the laws and regualtions of the country in which the observational study is conducted)

Exclusion criteria

* Age \< 18 y * Inability to understand the purpose of the study or refusal to cooperate * Not available for routine follow-up visits * Pregnancy * Currently participating in a confounding trial before reaching first endpoint.

Design outcomes

Primary

MeasureTime frameDescription
Primary Safety endpointFrom enrollment to the end of treatment, as per the standard of care.Proportion of subjects experiencing procedure- or device-related complications within 30 days including Post-ERCP pancreatitis, Bleeding, Perforation (biliary/pancreatic/duodenal), Stent misplacement, Stent migration, Biliary occlusion, Cholangitis, Severe pain, All-cause death Within 30 days of the index procedure

Secondary

MeasureTime frameDescription
Secondary endpoints are defined as:Technical and Procedural success on the Procedure day and clinical success as per the Standard of CareClinical success: patency rate as defined by the rate of freedom of stent replacements at follow-up time points defined by investigators definition of SOC (standard of care) or until planned bridge surgery (defined as no need of stent replacement). Technical success: Accurate stent deployment across the target stricture as evaluated by fluoroscopy and endoscopy. Procedural success will be quantified (using a dedicated score system, Excellence=1, Good=2, Fair=3, Poor=4) by the endoscopist post procedure using the following components: * Stent loadability * Trackability over Guide Wire * Pushibility with push catheter * Visualization by fluoroscopy * Stent repositiong when required * Deployment accuracy

Countries

Finland, France, Germany, Israel, Italy, Singapore, Slovenia, Spain