Skip to content

Understanding Potential Airborne Transmission and the Protective Value of Type II Surgical Masks in SARS-CoV-2

AeroCOVID 1: Understanding Potential Airborne Transmission and the Protective Value of Type II Surgical Masks in SARS-CoV-2 Using Patient Proximity Environmental Sampling With a Highly Efficient Bioaerosol and Droplet Collection Dummy

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04698837
Acronym
aeroCOVID1
Enrollment
30
Registered
2021-01-07
Start date
2021-02-02
Completion date
2021-12-31
Last updated
2022-05-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

SARS-CoV-2

Keywords

Airborne transmission, Aerosol transmission, Surgical masks

Brief summary

Modes of transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and specifically the proportion of airborne transmission in this infection is unknown. In the aeroCOVID study, a highly efficient bioaerosol and droplet sampling dummy is used to emulate a susceptible healthcare worker (HCW) and to perform patient proximity sampling. The dummy will measure the dummy-inhaled dose of SARS-CoV-2 in two particle size fractions in a standardized interaction with hospitalized coronavirus disease 2019 (COVID-19) patients. All measurements are performed in a masked and unmasked dummy setup in parallel, in order to gain further information on the protection of type II masks against the respective particle size exposure.

Detailed description

Modes of interpersonal transmission in SARS-CoV-2 are to date only incompletely understood and require further investigation in order to define best preventive measures. Although a dichotomization of inhaled particles by particle size is an oversimplification and a large particle size does not exclude shortterm airborne behavior, the suspension time of virus containing particles and the probability of particles to accumulate in room air is primarily defined by particle size distribution. Particles with a size below 10 µm have a high probability of accumulation due to their mean suspension time of minutes to hours. The study aims to measure the total amount of virus copies per particle size fraction inhaled by a highly efficient sampling dummy emulating a susceptible HCW in a standardized interaction with hospitalized COVID-19 patients. As a secondary endpoint, the proportion of culturable virus in each setup is measured as well. Sampling is done in using two parallel bioaerosol and droplet sampling dummies - one type II masked and one with an unmasked dummy head as inlet - in order to gain additional information on the protective effect of type II surgical masks in a real-life exhaled particle size distribution in hospitalized COVID patients. The sampling dummy consists of a real size face relief connected to an 60° inlet cone, a cyclone for collection of particles \>10 µm and a laminar flow water-based condensation bioaerosol collector for particle collection below 10 µm particle size. After patient proximity sampling, a nasopharyngeal swab for SARS-CoV-2 polymerase chain reaction (PCR) assay is performed. Relevant indoor climate parameters like temperature, humidity and carbon dioxide (CO2) as well as room characteristics as air change rate are recorded as well.

Interventions

None listed

Sponsors

University of Bern
CollaboratorOTHER
Lucerne University of Applied Sciences and Arts
CollaboratorUNKNOWN
Insel Gruppe AG, University Hospital Bern
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
18 Years to 110 Years
Healthy volunteers
No

Inclusion criteria

* positive SARS-CoV-2 PCR or antigen test from a nasopharyngeal or oropharyngeal swab * ≥18 years of age * ability to give consent * ability to follow simple instructions

Exclusion criteria

* symptom onset more than 10 days prior to inclusion * pregnancy * lack of written informed consent

Design outcomes

Primary

MeasureTime frame
Total amount of dummy-inhaled virus copies per 30 minutes sampling per size fraction (>10 µm, <10 µm)30 minutes sampling

Secondary

MeasureTime frame
Viability of dummy-inhaled viable virus per size fraction (>10 µm, and <10 µm)30 minutes sampling
Reduction of dummy-inhaled virus copies per 30 minutes sampling in a type II-masked setup, as compared to unmasked, per size fraction (>10 µm, <10 µm)30 minutes sampling

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026