Reliability of Myotonometry in Swimming Athletes

Reliability of Myotonometry in Swimming Athletes

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04697433
Enrollment
48
Registered
2021-01-06
Start date
2020-02-03
Completion date
2020-03-16
Last updated
2021-01-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Athletes

Brief summary

The clinical analysis of athletes has been performed in the sports field to obtain parameters for reliable evaluations. Among the tools used is the myotonometry, an analysis capable of quantitatively measuring tone, stiffness and elasticity. Its reliability has been tested in several populations, however, showing changes in results and presenting high variability in the confidence interval, also, the values of myotonometry differ according to sample specificity and the biomechanical properties of each muscle. Therefore, it seems pertinent to perform the reliability analysis in swimming athletes and verify their applicability and if the values of tone and muscular biomechanical properties vary according to the specificity of the modality. It will be a test and retest study composed of 50 young male and female swimming athletes, aged between 12 and 20 years. The evaluation of myotonometry will be performed randomly by two evaluators and the parameters measured will be: tone, stiffness, elasticity, relaxation time of mechanical stress and displacement. In the test stage, the first evaluator will perform the measurements bilaterally on the muscles and the second evaluator will perform the same measurements in the same order immediately after the first one. After 15 minutes, the retest will be performed following the same order of evaluators in the test. For characterization of sample will be used descriptive statistic through central tendency and variability for all variables collected. Relative reliability will be tested by the Intraclass Correlation Coefficient (ICC). Absolute reliability will be verified by means of standard error of measurement (SEM), values of least detectable change (MMD) and coefficient of variation (CV). The statistical package SPSS Statistics 22.0 will be used to conduct the reliability analyses.

Interventions

DEVICEMyotonometry

The examiner should exert a slight pressure on the determined point to the necessary depth, which will be indicated by changing the color from red to green light on the device. The device has an automatically controlled preload (0.18 Newton (N)) that will be applied to the contact area by an automatic mechanical pulse, with a duration of 15 milliseconds (ms) and a constant force of 0.4 N , these oscillations will be registered by an accelerometer next to the measurement mechanism inside the device. For each evaluation, a series of 10 consecutive pulses (multiscan mode) will be used with an interval of one second between each pulse. In each shot, the tone, stiffness, elasticity, relaxation time and creep will be calculated.

Sponsors

São Paulo State University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
12 Years to 20 Years
Healthy volunteers
Yes

Inclusion criteria

* Healthy swimming athletes

Exclusion criteria

* Being an alcoholic, consuming drugs, smoking or anti-inflammatory and / or analgesic drugs less than 24 hours before the test, presenting anemia, inflammatory process, diabetes, cardiovascular disease, episodes of muscle-tendon or osteoarticular injury in the lower, upper and / or lower limbs spine in the last three months, in addition to swimming for less than two years.

Design outcomes

Primary

MeasureTime frameDescription
Muscle Tone75 minutesMyotonPro (MyotonAS, Tallinn, Estonia), measured in Hertz (Hz)
Stiffness75 minutesMyotonPro (MyotonAS, Tallinn, Estônia), measured in Newton / meter (N/m)

Secondary

MeasureTime frameDescription
Elasticity75 minutesMyotonPro (MyotonAS, Tallinn, Estonia)
Mechanical Stress Relaxation Time75 minutesMyotonPro (MyotonAS, Tallinn, Estonia), measured in milliseconds (ms)
Creep75 minutesMyotonPro (MyotonAS, Tallinn, Estonia)