EMG-Based Hand-Wrist Control: Study B Mirrored

EMG-Based Hand-Wrist Control: Study B: Comparison of Contralateral (Mirrored) EMG-

Status
Completed
Phases
Early Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04692571
Acronym
PSICON-B
Enrollment
20
Registered
2021-01-05
Start date
2017-06-29
Completion date
2020-08-24
Last updated
2021-01-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Amputation, Amputation, Congenital, Amputation; Traumatic, Hand, Prosthesis User

Keywords

prosthesis, electromyography, EMG, sEMG, control, myo, regression, transradial, terminal device, electrodes

Brief summary

Study assessing four-channel prosthesis controller, that compares contralateral (mirrored) EMG-force training to ipsilateral EMG-target training with both limb-absent and able-bodied subjects

Detailed description

System identification models relating forearm electromyogram (EMG) signals to phantom wrist radial-ulnar deviation force, pronation-supination moment and/or hand open-close force (EMG-force) are hampered by lack of supervised force/moment output signals in limb-absent subjects. In able-bodied and unilateral transradial limb-absent subjects, we studied three alternative supervised output sources in one degree of freedom (DoF) and 2-DoF target tracking tasks: (1) bilateral tracking with force feedback from the contralateral side (non-dominant for able-bodied/ sound for limb-absent subjects) with the contralateral force as the output, (2) bilateral tracking with force feedback from the contralateral side with the target as the output, and (3) dominant/limb-absent side unilateral target tracking without feedback and the target used as the output.

Interventions

DEVICEPSICON Measurement Apparatus

Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist \[hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)\]. sEMG system used 16 custom encased bipolar electrodes. A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC. A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement. A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces. The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target. The subject controlled a second triangular cursor. Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.

Sponsors

Worcester Polytechnic Institute
CollaboratorOTHER
Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)
CollaboratorNIH
Liberating Technologies, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SEQUENTIAL
Primary purpose
BASIC_SCIENCE
Masking
NONE

Intervention model description

Transradial limb-absent vs able-bodied subjects tested in sequence.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Limb-absent subjects: unilateral trans-radial limb absence or amputation * Be capable of completing the requested contractions on the affected dominant side

Exclusion criteria

* Past injuries to the upper limbs that would limit their ability to complete the requested contractions * Scars that would impede the use of surface electrodes

Design outcomes

Primary

MeasureTime frameDescription
EMG-Force Models1 day visitElectromyogram waveform measurements (signal amplitude, frequency) will be related to force measurements (magnitude and moment) as related to the target tracking tasks. These signal-force data will be use to generate the models. The specific outcome for each subject will be the RMS error measured in the tracking tasks as the difference between the generated control signal from the user versus the prompted target signal, as measured by an EMG array.

Countries

United States

Outcome results

None listed