Skip to content

Evaluation of PSMA Antagonist Produced by Two Different Methods

Evaluation of a 68Ga Small Molecule PSMA Antagonist Produced by Two Different Methods

Status
Completed
Phases
Phase 1Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04685811
Enrollment
16
Registered
2020-12-28
Start date
2020-12-09
Completion date
2021-06-30
Last updated
2022-09-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Metastatic Prostate Adenocarcinoma

Keywords

Prostate Cancer

Brief summary

Patients with metastatic prostate cancer will undergo two protocol 68Ga-PET scans within 24-48 hours with 68Ga-PSMA-cyclotron and 68Ga-PSMA-generator radiotracers. The goal of the study is to evaluate repeatability and equivalence across the different 68Ga-PSMA production methods. This research study is being conducted to assess whether the PET/CT imaging results, as generated from the two different 68Ga production methods, are equivalent.

Detailed description

Patients with metastatic prostate adenocarcinoma will be enrolled in the study and will undergo two 68Ga-Prostate Specific Membrane Antigen- Positron Emission Tomography (PSMA-PET) scans within 24-48 hours. The difference between the two scans is that the radiotracer used in each scan will be produced with a different method (68Ga-PSMA-cyclotron and 68Ga-PSMA-generator produced). The first scan will occur after a baseline clinical evaluation, which will include a history, physical, and baseline lab draw. After each scan, blood draws will be obtained. The purpose of this study is to evaluate equivalence of two processes to create 68Ga-HBED-PSMA and compare dosimetry, biodistribution and whole body excretion/ metabolism. Furthermore, the research team will perform dynamic analysis of the PET scans to investigate repeatability of whole-body 68Ga-PSMA-generator Ki Patlak imaging against that of conventional whole-body 68Ga-PSMA- SUV imaging and evaluate equivalence of whole-body 68Ga-PSMA Ki Patlak imaging between the two processes to create 68Ga-HBED-PSMA (68GA-PSMA-cyclotron vs. 68Ga-PSMA-generator). Patients will afterwards receive standard of care treatment and follow up imaging.

Interventions

DRUG68Ga-PSMA-generator vs. 68Ga-PSMA-cyclotron

68Ga-PSMA-generator vs. 68Ga-PSMA-cyclotron; single dose each, approximately 100-300 mBq.

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
National Cancer Institute (NCI)
CollaboratorNIH
Weill Medical College of Cornell University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
21 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

Subjects must meet all of the following criteria to be enrolled in this study: * Aged 21 years or older and below 80 years of age * Signed written informed consent and willingness to comply with protocol requirements * Histologically confirmed diagnosis of metastatic prostate cancer * Staging imaging exam confirming metastatic disease, e.g. total body MRI, or CT chest/abdomen/pelvis, 99mTc bone scan, NaF PET

Exclusion criteria

* Laboratory values: * Serum creatinine \>2.5 mg/dL * AST (SGOT) \>2.5x ULN * Bilirubin (total) \>1.5x ULN * Serum calcium \>11 mg/dL * Presence of any other co-existing condition which, in the judgment of the investigator, might increase the risk to the subject. * Presence of serious systemic illness, including: uncontrolled inter-current infection, uncontrolled malignancy, significant renal disease, or psychiatric/social situations, which might limit compliance with study requirements. * Other severe acute or chronic medical condition(s) or laboratory abnormality(ies) that may increase the risk associated with study participation or investigational product administration or may interfere with the interpretation of study results and in the judgment of the investigator, would make the patient inappropriate for entry into this study. * Inability to lay on the scanner table for the required period of time, e.g., due to bone pain or claustrophobia.

Design outcomes

Primary

MeasureTime frameDescription
Evaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic Lesions2 study visits between 24 to 48 hours apartSingle score Intraclass Correlation Coefficient (ICC) was calculated as an index for reliability between 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator across varying pathologic lesions. The ICC, based on a one-way random effects model was used to assess reliability. The ICC ratios in this data shows the top five lesions with the greatest PSMA uptake (SUV) in each patient. This is a measure of the variance of interest (for the patient's lesion) over the total variance (from all data points for that particular lesion of interest). Repeatability was evaluated by calculating the variance among group means of the SUVmean and SUVmax of each reference and lesion over the sum of the group-level and datalevel (residual) variance. The lesions reported in this analysis range from the SUV of reference organs to the average SUV of a metastatic deposit. These scans were also performed within 48 hours of each other to limit heterogeneity that may correspond to disease progression or PSMA avidity.
Evaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Average SUV Max-pathologic Regions2 study visits between 24 to 48 hours apartSingle score intraclass correlation coefficient (ICC) was calculated as an index for reliability between 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator across varying average SUV Max-pathologic regions The ICC ratios in this data provides a general performance review of uptake in both pathological lesions and reference lesions, specifically the average SUVmax of bone metastases, lymph nodes, salivary glands, and the spleen.
ICC Between Generator PSMA Scan vs Cyclotron PSMA Scan: Total Lesion Average SUVMax2 study visits between 24 to 48 hours apartRepeatability was evaluated by calculating the variance among group means of the SUVmean and SUVmax of each reference and lesion over the sum of the group-level and datalevel (residual) variance. The intraclass correlation coefficient (ICC), based on a one-way random effects model (i.e., assumes subjects are randomly selected from the larger population), was used to assess reliability between generator and cyclotron scanning methods. BlandAltman analysis evaluated the agreement between the two scanning methods. Confidence levels of 95% were estimated to assess precision of the obtained estimates. All analyses were performed in R Version 4.0.5 (R Foundation for Statistical Computing, Vienna, Austria).

Secondary

MeasureTime frameDescription
Evaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Max SUV -Pathologic Regions2 study visits between 24 to 48 hours apartSingle score intraclass correlation coefficient (ICC) was calculated as an index for reliability between 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator across varying Max SUV -pathologic regions Repeatability was evaluated by calculating the variance among group means of the SUVmean and SUVmax of each reference and lesion over the sum of the group-level and datalevel (residual) variance. The intraclass correlation coefficient (ICC), based on a one-way random effects model (i.e., assumes subjects are randomly selected from the larger population), was used to assess reliability between generator and cyclotron scanning methods. BlandAltman analysis evaluated the agreement between the two scanning methods. Confidence levels of 95% were estimated to assess precision of the obtained estimates. All analyses were performed in R Version 4.0.5 (R Foundation for Statistical Computing, Vienna, Austria).
Compare Bio-Distribution Between 68GA-PSMA-cyclotron vs. 68Ga-PSMA-generator2 study visits between 24 to 48 hours apartThe biodistribution of 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator will be evaluated by measuring the radioactivity concentration in various organs of interest. Based on the SUVmean and SUVmax, the RC unit will be used to compare these scans. PSMA positivity was defined as having a SUV value above that of the reference blood pool, liver, and/or salivary glands when evaluating lesions as described using the PROMISE criteria15. Quantitative analysis reviewed the SUVmax and SUVmean of the parotid gland, liver, and aortic arch (blood pool), as well as the SUVmax and SUVmean of suspected metastatic lesions. The same ROIs were evaluated on both scans for each respective patients.

Countries

United States

Participant flow

Participants by arm

ArmCount
ICC Between Generator PSMA Scan vs Cyclotron PSMA Scan: Total Lesion Average SUVMax
Intraclass Correlation Coefficient (ICC) between Generator PSMA Scan vs Cyclotron PSMA Scan: Total Lesion Average SUVMax
16
Total16

Baseline characteristics

CharacteristicICC Between Generator PSMA Scan vs Cyclotron PSMA Scan: Total Lesion Average SUVMax
Age, Continuous73 years
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
2 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
14 Participants
Region of Enrollment
United States
16 participants
Sex: Female, Male
Female
0 Participants
Sex: Female, Male
Male
16 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 16
other
Total, other adverse events
0 / 16
serious
Total, serious adverse events
0 / 16

Outcome results

Primary

Evaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Average SUV Max-pathologic Regions

Single score intraclass correlation coefficient (ICC) was calculated as an index for reliability between 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator across varying average SUV Max-pathologic regions The ICC ratios in this data provides a general performance review of uptake in both pathological lesions and reference lesions, specifically the average SUVmax of bone metastases, lymph nodes, salivary glands, and the spleen.

Time frame: 2 study visits between 24 to 48 hours apart

ArmMeasureGroupValue (NUMBER)
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Average SUV Max-pathologic RegionsAverage SUV Max - Bone Lesions0.96 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Average SUV Max-pathologic RegionsAverage SUV Max - Lymph Nodes0.86 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Average SUV Max-pathologic RegionsAverage SUV Max - Salivary Glands and Parotids0.70 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Average SUV Max-pathologic RegionsAverage SUV Max - Spleen0.82 ICC estimate
Primary

Evaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic Lesions

Single score Intraclass Correlation Coefficient (ICC) was calculated as an index for reliability between 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator across varying pathologic lesions. The ICC, based on a one-way random effects model was used to assess reliability. The ICC ratios in this data shows the top five lesions with the greatest PSMA uptake (SUV) in each patient. This is a measure of the variance of interest (for the patient's lesion) over the total variance (from all data points for that particular lesion of interest). Repeatability was evaluated by calculating the variance among group means of the SUVmean and SUVmax of each reference and lesion over the sum of the group-level and datalevel (residual) variance. The lesions reported in this analysis range from the SUV of reference organs to the average SUV of a metastatic deposit. These scans were also performed within 48 hours of each other to limit heterogeneity that may correspond to disease progression or PSMA avidity.

Time frame: 2 study visits between 24 to 48 hours apart

ArmMeasureGroupValue (NUMBER)
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic LesionsLesion 50.97 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic LesionsLesion 10.98 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic LesionsLesion 20.98 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic LesionsLesion 30.99 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Pathologic LesionsLesion 40.99 ICC estimate
Primary

ICC Between Generator PSMA Scan vs Cyclotron PSMA Scan: Total Lesion Average SUVMax

Repeatability was evaluated by calculating the variance among group means of the SUVmean and SUVmax of each reference and lesion over the sum of the group-level and datalevel (residual) variance. The intraclass correlation coefficient (ICC), based on a one-way random effects model (i.e., assumes subjects are randomly selected from the larger population), was used to assess reliability between generator and cyclotron scanning methods. BlandAltman analysis evaluated the agreement between the two scanning methods. Confidence levels of 95% were estimated to assess precision of the obtained estimates. All analyses were performed in R Version 4.0.5 (R Foundation for Statistical Computing, Vienna, Austria).

Time frame: 2 study visits between 24 to 48 hours apart

ArmMeasureValue (NUMBER)
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanICC Between Generator PSMA Scan vs Cyclotron PSMA Scan: Total Lesion Average SUVMax0.97 ICC estimate
Secondary

Compare Bio-Distribution Between 68GA-PSMA-cyclotron vs. 68Ga-PSMA-generator

The biodistribution of 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator will be evaluated by measuring the radioactivity concentration in various organs of interest. Based on the SUVmean and SUVmax, the RC unit will be used to compare these scans. PSMA positivity was defined as having a SUV value above that of the reference blood pool, liver, and/or salivary glands when evaluating lesions as described using the PROMISE criteria15. Quantitative analysis reviewed the SUVmax and SUVmean of the parotid gland, liver, and aortic arch (blood pool), as well as the SUVmax and SUVmean of suspected metastatic lesions. The same ROIs were evaluated on both scans for each respective patients.

Time frame: 2 study visits between 24 to 48 hours apart

ArmMeasureGroupValue (NUMBER)
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanCompare Bio-Distribution Between 68GA-PSMA-cyclotron vs. 68Ga-PSMA-generatorTotal Lesion Average Coefficient Variation0.97 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanCompare Bio-Distribution Between 68GA-PSMA-cyclotron vs. 68Ga-PSMA-generatorTotal Lesion Average SUV Max0.97 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanCompare Bio-Distribution Between 68GA-PSMA-cyclotron vs. 68Ga-PSMA-generatorTotal Lesion Average SUV Mean0.71 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanCompare Bio-Distribution Between 68GA-PSMA-cyclotron vs. 68Ga-PSMA-generatorTotal Lesion Average Standard Deviation0.94 ICC estimate
Secondary

Evaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Max SUV -Pathologic Regions

Single score intraclass correlation coefficient (ICC) was calculated as an index for reliability between 68GA-PSMA-cyclotron versus 68Ga-PSMA-generator across varying Max SUV -pathologic regions Repeatability was evaluated by calculating the variance among group means of the SUVmean and SUVmax of each reference and lesion over the sum of the group-level and datalevel (residual) variance. The intraclass correlation coefficient (ICC), based on a one-way random effects model (i.e., assumes subjects are randomly selected from the larger population), was used to assess reliability between generator and cyclotron scanning methods. BlandAltman analysis evaluated the agreement between the two scanning methods. Confidence levels of 95% were estimated to assess precision of the obtained estimates. All analyses were performed in R Version 4.0.5 (R Foundation for Statistical Computing, Vienna, Austria).

Time frame: 2 study visits between 24 to 48 hours apart

ArmMeasureGroupValue (NUMBER)
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Max SUV -Pathologic RegionsMax SUV - Aorta0.59 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Max SUV -Pathologic RegionsMax SUV - Liver0.91 ICC estimate
Comparison of Generator PSMA Scan vs. Cyclotron PSMA ScanEvaluate Equivalence Between 68GA-PSMA-cyclotron and 68Ga-PSMA-generator Across Varying Max SUV -Pathologic RegionsMax SUV - Parotid0.78 ICC estimate

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026