Skip to content

Absolute Quantification in Bone Scintigraphy

Absolute Quantification in Bone Scintigraphy: Phantom Evaluation and Clinical Application in Patients Undergoing Follow-up for Vertebral Fractures.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04671238
Acronym
QUANTOSS-3D
Enrollment
21
Registered
2020-12-17
Start date
2020-01-01
Completion date
2021-02-01
Last updated
2022-09-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Scintigraphy Quantification

Keywords

bone scintigraphy, absolute quantification, Standard Uptake Value

Brief summary

While absolute quantification in 18F-FDG PET (Positon Emission Tomography) is widely used in clinical routine, absolute quantification in SPECT (Single Photon Emission Computed Tomography) is under development and its clinical interest remains to be demonstrated. Recent studies carried out on bone scan recordings show the potential interest of quantification indexes such as SUV (Standard Uptake Value).

Detailed description

In oncology, bone scan studies have reported significantly higher SUV values for secondary bone lesions compared with benign osteoarticular lesions , and some have even defined an SUVmax threshold value that points to prostatic bone metastases.

Interventions

DEVICESPECT CT

SPECT/CT scan of the spine as part of a vertebroplasty

Sponsors

Central Hospital, Nancy, France
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with recent vertebral fractures: 1. who have had at least two SPECT/CT scan scans of the spine as part of a pre-vertebroplasty check-up, 2. for which fracture dates were known.

Exclusion criteria

1. Minor person 2. Person opposing the use of their data (Posters in waiting rooms explaining that the patient must object if they do not wish their data to be used)

Design outcomes

Primary

MeasureTime frameDescription
To validate the absolute bone scan quantification in a retrospectively selected patient populationAfter 1 yearAnalysis of SUV variation on at least 2 bone scans: Variation of the SUV over time on scans of patients with spinal fractures

Secondary

MeasureTime frameDescription
To calibrate the tomographic images from the gamma camera1 dayCalibrate the tomographic images from the gamma camera to obtain a volume activity in Bq/mLand densities
To evaluate the attenuation correction on phantoms of different density1 daySUV absolute quantitation index (SUVmax, SUVpeak, SUVmean).
To evaluate absolute quantification on phantoms1 dayEvaluate absolute quantification on phantoms with objects of different volumes

Countries

France

Outcome results

None listed