Efficacy and Safety of the DYNAtraq Device to Prevent Complications in Tracheostomy in Mechanically Ventilated Patients

A Clinical, Controlled, Randomized Trial to Evaluate the Efficacy and Safety of the New Dynatraq Invention Device to Prevent Complications Associated With Tracheostomy Tubes in Mechanically Ventilated Patients: Dynatraq-2 Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04668742
Acronym
DYNAtraq
Enrollment
74
Registered
2020-12-16
Start date
2019-11-25
Completion date
2022-01-25
Last updated
2022-04-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Ventilation Complication, Tracheostomy

Keywords

tracheostomy, airway, complications

Brief summary

Although tracheostomy is a common technique in Intensive Care Units (ICU), its complications can be frequent (between 5% to 40%). Inadequate fixation could favor decannulation, as well as incorrect alignment of the tracheostomy with respect to the tracheal axis could favor the appearance of tissue alterations such as ulcers, bleeding or fistulas, as well as obstruction of the ventilatory obstruction. Having a device that is effective in fixation and alignment could help in reducing tracheostomy complications, so this study aims to evaluate the effect and safety of a fixation device for tracheostomy through a randomized clinical trial.

Detailed description

Introduction: Tracheostomy is one of the most frequently required surgical techniques for the management of hospitalized patients in Intensive Care Units (ICU). This procedure is justified to facilitate the improvement of the patient, facilitate early rehabilitation, reduce sedation and analgesia requirements, and reduce the length of stay in the ICU and the days of mechanical ventilation (MV). However, tracheostomy is associated with various complications, from mispositioning and accidental decannulation, to hemoptysis, tracheal fistulas, air leaks, and ventilatory difficulties. In a pre-post quasi-experimental study where the effect of the DYNAtraq technological innovation device on tracheostomy fixation and alignment was evaluated, it was found that it can correct 83% of cases, which contrasts with only 2% when they did not have the device. (p \<0.01). This previous study allowed us to conclude that technological innovation through DYNAtraq is pertinent, relevant and effective to correct the position of tracheostomy tubes in patients hospitalized in the ICU and under mechanical ventilation. Objective: To evaluate the efficacy and safety of the DYNAtraq medical device to keep tracheostomy tubes in correct alignment and fixation in adult patients with tracheostomy hospitalized in the ICU and under invasive mechanical ventilation. Methodology: Randomized, controlled clinical trial (two-parallel arm), assigned in a 1: 1 ratio, in a sample of 74 patients mechanically ventilated in intensive care unit (37 in intervention group and 37 patients in control group). This study is conducted in two centers for intensive care patients in two Colombian cities and The patients randomized to the intervention group will have the external fixation system for the tracheostomy installed, which is a non-invasive plastic device, from the start of the tracheostomy to ventilatory weaning. Patients in the control group will receive the usual management of the tracheostomy given in ICU. To evaluate alignment , the cephalo-caudal (C-C) and lateral-lateral (L-L) angles will be evaluated through photographs and analyzed with the SAPO application. The mean values of the angles were obtained in degrees and their 95% confidence intervals. Angular means were compared using the paired Student's t test. Expected Results: The DYNAtraq device is expected to be effective in improving the proper fixation, orientation, and alignment of the tracheostomy tube in mechanically ventilated patients, reducing the complications of lacerations, bleeding, decannulation, and respiratory infectious complications.

Interventions

DEVICEDYNAtraq

Tracheostomy alignment with DYNAtraq

Sponsors

Instituto Colombiano para el Desarrollo de la Ciencia y la Tecnología (COLCIENCIAS)
CollaboratorOTHER_GOV
Plasticos de Santander Ltda PLADESAN
CollaboratorUNKNOWN
Fundación Cardiovascular de Colombia
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Investigator)

Masking description

masking of the intervention and control groups in the statistical analysis of the data, which will be represented as group 0 and 1, without identifying whether they are control or intervention

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 18 years of age * Indication for a tracheostomy * Signature of informed consent

Exclusion criteria

* Mediastinitis * Open chest * Chest skin infection /burns anterior region of the thorax * Patients requiring reanimation * Active phase of COVID-19

Design outcomes

Primary

MeasureTime frameDescription
Presence of mis-alignment of tracheostomy tube72 hours after tracheostomy installationDeviation from 95° angle of tracheostomy tube (cephalo-caudal (C-C) and lateral-lateral (L-L) angles) No evidence of alignment of tube though bronchoscopy

Secondary

MeasureTime frameDescription
Presence of complications of tracheostomy72 hours after tracheostomy installationEvidence of any complication due to tracheostomy (infections, bleeding, extubation, death)

Other

MeasureTime frameDescription
Presence of skin lesion72 hours after tracheostomy installationSafety of the device in skin (adhesive)

Countries

Colombia

Outcome results

None listed