Skip to content

Trunk Control Tests in Post-stroke Context: Validity and Reliability Study

Trunk Joint Positional Sense and Unstable Sitting Balance Tests in Patients With Hemiparesis Post-stroke: Validity and Reliability Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04639453
Enrollment
32
Registered
2020-11-20
Start date
2019-06-01
Completion date
2021-03-29
Last updated
2021-03-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Stroke

Keywords

Stroke, Trunk, Postural control, Reliability, Validity

Brief summary

Context: After stroke, most patients suffer from hemiparesis with variable functional consequences that can strongly impact autonomy in daily activities. Motor recovery is, therefore, an essential part of the therapeutic strategy in order to optimize the patient's capacities and functional autonomy. Some authors suggest that trunk control would be essential in the capacities of standing balance, transfer tasks and gait. However, no studies have tested the reliability and validity of proprioceptive and sitting balance clinical tests for patients with post-stroke hemiparesis. These tests would be very useful in advancing our understanding of trunk impairments and for clinicians to manage an appropriate treatment strategy. Objective: The main objective is to assess the reliability of the Trunk Positional Sense Test, the unstable sitting test with forceplate and the Modified Functional Reach Test (MFRT) in individuals with post-stroke hemiparesis. The secondary objectives is 1) to assess the validity of the Trunk Positional Sense Test and the unstable sitting test with forceplate, 2) to assess the validity of a phone inertial captors to assess the instable sitting. Method. - Thirty-two individuals with subacute post-stroke hemiparesis will be included in this study. After clinical tests (trunk strength, Balance Assessment in Standing and Sitting, Timed Up and Go test), the MFRT, Trunk Positional Sense Test and unstable sitting will be evaluated by two physiotherapists in a first session (inter-rater reliability). After a rest of 2-4 h, a second similar session was conducted with the first physiotherapist (intra-rater reliability). For unstable seated balance, two tools will be used: the force platform and a smartphone. Reliability will be tested by calculating the intraclass correlation (ICC) and Bland-Altman analysis. For trunk positional sense test and unstable sitting test, the validity will be tested with correlations with each clinical test. The validity, between forceplate variables and inertial phone variables, will be tested with correlations. Perspectives. - The promotion of quality tests to assess patients in clinical practice is essential. The results of this study should provide knowledge for selecting the best trunk control tests to assess the individuals after stroke and to understand the influence of trunk control on functional activities.

Interventions

DIAGNOSTIC_TESTTrunk strength with hand-held dynamometer

MicroFET 2 Handheld Dynamometer is a force evaluation testing device to evaluate the strength of various trunk muscle groups in flexion, extension, and lateral (N).

DIAGNOSTIC_TESTBalance Assessment in Sitting and Standing test (BASS)

The BASS is a test to assess static and dynamic sitting and standing balance, which has been validated for post-stroke hemiparetic patients. Each test is evaluated by a score from 0 (patient needs external support) to 4 (stable without external help) for static condition and from 0 (no possibility to pick up objects) to 3 (objects picked up without external help) for dynamic condition. The maximal score (sitting, standing, static and dynamic) is 14 points.

DIAGNOSTIC_TESTTimed Up and Go test

The participant sits on a chair, gets up, walks 3m, makes a half turn in 1m2, walks 3m and comes back to sit on the chair. The time (s) to complete the task is measured.

DIAGNOSTIC_TESTModified Functional Reach Test (MFRT)

The MFRT is a dynamic seated balance test that measures the trunk's ability to move forward, to the paretic and non paretic side (cm).

DIAGNOSTIC_TESTJoint Position sense test (trunk)

The joint positional sense test of the trunk consists in evaluating the positional error of the trunk in the sagittal plane (mm) and in the frontal plane (mm) during a trunk flexion posture (target position).

DIAGNOSTIC_TESTUnstable sitting in a seesaw

This test evaluates the balance capacities of the subject in an unstable sitting position on a seesaw (mediolateral or anteroposterior instability) with forceplate and phone application using center of pressure variables: total displacement (mm), area (mm2), deltas (mm), mean velocity (mm/s) et maximal velocity (mm/s).

Sponsors

University Hospital, Geneva
CollaboratorOTHER
Anne-Violette Bruynnel
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
50 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Post stroke * Subacute phase * Able to stay stable in sitting position during 30 seconds * Medical stability * Able to understand the consign (Mini-Mental State Examination \>22)

Exclusion criteria

* Medical complications * Hearing disorders * Previous pathologies associated with spinal disorders * Back pain

Design outcomes

Primary

MeasureTime frameDescription
Reliability of trunk testsThe measures will be collected over a timeframe of 22 monthsThe inter-rater reliability will be evaluated by comparing the test results of two physiotherapists administering the same tests (Trunk position sense, Modified Functional Reach Test, unstable sitting on a seesaw), and the intra-rater reliability will be evaluated by comparing the test results of two sessions (test-retest) which will be executed by the same tester, with the intra-class correlations coefficient (ICC) and Bland-Altman analysis.

Secondary

MeasureTime frameDescription
Construct validityThe measures will be collected over a timeframe of 22 monthsThe validity of the three tests (Trunk position sense, Modified Functional Reach Test, unstable sitting on a seesaw) with clinical tests (Balance Assessment in standing and sitting, Trunk strength, Timed Up and Go Test) will be assessed with correlations (r).
Concurrent validityThe measures will be collected over a timeframe of 22 monthsThe validity between center of pressure variables (forceplate) and inertial captors' variables (phone) during the same unstable sitting balance tests on a seesaw will be assessed with correlations (r) and Bland Altman analysis.

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026