Skip to content

Effects of Different Tidal Volume Ventilation Strategies on Fontan Flow and Hemodynamics

Effects of Different Tidal Volume Ventilation Strategies on Fontan Flow and Hemodynamics

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04633343
Enrollment
12
Registered
2020-11-18
Start date
2021-02-22
Completion date
2022-08-30
Last updated
2025-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fontan Physiology

Brief summary

In patients with Fontan circulation blood is not pumped to the lungs from a ventricle. Instead the superior vena cava and inferior vena cava is connected to the pulmonary artery and blood flow to the lungs occurs passively along this Fontan pathway. This passive blood flow to the lungs occurs best when the patient is breathing on their own (spontaneous ventilation). However for certain surgeries and procedures patients need to have an endotracheal tube inserted and need to be muscle relaxed and receive positive pressure ventilation. Prior studies have shown that positive pressure ventilation can reduce blood flow to the lungs and consequently blood returning to the heart resulting in less blood pumped out to the rest of the body (cardiac output). The purpose of this study is to investigate if changing the volume of the positive pressure ventilation (tidal volume) affects blood flow to the lungs and cardiac output in patients with Fontan circulation.

Detailed description

If it can be shown that changing the tidal volume does affect the blood flow to the lungs and cardiac output in patients with Fontan circulation the information can be used to learn from this study to optimize the tidal volume ventilation, and therefore pulmonary blood flow and cardiac output when Fontan patients come for general anesthesia. This is important because the population of patients with Fontan circulation is increasing and an increasing number will present for cardiac and non cardiac surgery when positive pressure ventilation will be required. They may also spend time on the cardiac intensive care unit on a ventilator and improving our knowledge on how best to ventilate them may help improve their overall hospital outcomes.

Interventions

OTHERSmall volume breath and fast breathing rate for 5 minutes

Small volume breath and fast breathing rate delivered via mechanical ventilator.

OTHERLarge volume breath and slow breathing rate for 5 minutes

Large volume breath and slow breathing rate delivered via mechanical ventilator.

Sponsors

Stanford University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
2 Years to 50 Years
Healthy volunteers
No

Inclusion criteria

1. Age 2- 50 years of age 2. Patients with Fontan circulation undergoing cardio-thoracic surgery or undergoing cardio-thoracic surgery for completion of Fontan circulation.

Exclusion criteria

1\. Patients presenting for cardio-thoracic surgery without Fontan circulation or those not coming for completion of Fontan circulation.

Design outcomes

Primary

MeasureTime frameDescription
Transpulmonary gradient5 minutes of change in Tidal Volume (high vs low)Effect of tidal volume changes (high vs low) on Transpulmonary gradient as measured as the difference between mean pulmonary artery pressure measured from right internal jugular (Fontan pressure line) and left atrial pressure measured by direct intracardiac pressure line. Both lines are placed for the scheduled clinical procedure and not solely for the purposes of the research study.

Secondary

MeasureTime frameDescription
Blood flow in inferior vena cava (IVC)5 minutes of change in Tidal Volume (high vs low)Effect of tidal volume changes (high vs low) on blood flow in inferior vena cava (IVC) as measured by Transesophageal Echocardiography TEE)..
Systemic outflow tract stroke distance (velocity time integral)5 minutes of change in Tidal Volume (high vs low)Effect of tidal volume changes (high vs low) on systemic outflow tract stroke distance (velocity time integral) as measured by Transesophageal Echocardiography. (TEE).

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026