Skip to content

Investigation of the Wash-out Effect of Intravenous Iron by Cell Savers (WASH-OUT)

Investigation of the Wash-out Effect of Intravenous Iron by Cell Savers

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04631679
Acronym
WASH-OUT
Enrollment
23
Registered
2020-11-17
Start date
2019-11-08
Completion date
2021-04-29
Last updated
2021-10-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anemia, Anemia, Iron Deficiency, Iron Deficiency Anemia Treatment

Keywords

Anemia, Cell Saver, Iron Deficiency Anemia, Intravenous Iron, Ferric Carboxymaltose, Wash Out

Brief summary

The study is a pilot study, which involves cardiothoracic patients. Patients, who are scheduled for elective cardiosurgical procedure, will be seen in multidisciplinary anesthesia/Patient Blood Management (PBM) clinic and screened for anemia prior to surgery. Anemic patients will eventually be treated with 500mg of ferric carboxymaltose 1 to 4 days prior to surgery. A high blood loss is expected in these procedures (\>500ml). Blood is collected and re-transfused to the patient via use of cell savers/ autologous blood restoration. The investigators will examine how fast intravenous ferric carboxymaltose is stored within the iron storage cells of the body, and how much remains within the patients blood at the time point of surgery. Next, the investigators will assess the wash out effect of iron via cell salvage. The hypothesis of this trial is that ferric carboxymaltose is washed out of the collected patient's blood by cell caver usage (Wash-Out Effect).

Detailed description

Because of the short time frame between iron therapy to procedure in cardiac surgery due to the need to perform cardiac revascularization, the investigators aim to investigate how much of the iron compound ferric carboxymaltose is being stored within the iron storage cells of the human body, and how much remains in the patient's own blood at the time point of surgery. The terminal elimination half-life time of ferric carboxymaltose is known to be approximately 7.1 to 12.1 hours, with peak serum ferritin levels at 48h to 120h after administration. When high blood loss in a surgical procedure is expected, such as in cardiosurgical procedures, the usage of autologous cell salvage, so called Cell Saver, is considered standard, good practice. The blood that is lost during surgery is collected and after a specified blood separation wash, being retransfused in form of concentrated red blood cells. This trial aims to examine whether Cell Saver usage might recover high molecular iron complexes such as ferric carboxymaltose lost by bleeding intraoperatively or wash out these molecules. If amount of lost blood during surgery is too low, that Cell Saver usage would not be possible otherwise, averagely 300ml of blood from the heart-lung machine are added to the cell saver to enable the process of cell saver use. For each participant, 7 samples will be taken. The samples include patient's blood samples and samples from cell saver compartments (Washing solution, concentrates) as well as from the heart-lung-machine, in detail: 1. arterial patient's blood, preoperative, day of procedure, prior to surgery 2. blood from the heart-lung machine, intraoperative 30 minutes prior to end of use of the heart-lung machine, day of procedure 3. Cell Saver: washed-out compounds, intraoperative, after end of use of heart-lung machine, day of procedure 4. Cell Saver: produced red blood cell concentrate, intra- or postoperative, after end of use of heart-lung machine, day of procedure 5. arterial patient's blood, postoperative, day of procedure 6. venous patient's blood, 3. day postoperative 7. venous patient's blood, 7. day postoperative By liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS) levels of ferric carboxymaltose are examined 1. in the patient's blood prior to surgery to determine the amount of ferric carboxymaltose within the patients blood prior to surgery, and after a certain time after the intravenous Infusion of ferric carboxymaltose (12-96 hours). 2. pre- and postoperatively and in cell saver compartments. If ferric carboxymaltose is detected in the washing solution of the Cell Saver System and not within the stored red blood cell concentrate, ferric carboxymaltose is washed out by the cell saver.

Interventions

None listed

Sponsors

University of Muenster, Institute of Inorganic and Analytical Chemistry
CollaboratorUNKNOWN
University Hospital Muenster
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* scheduled cardiosurgical procedure such as valve surgery, aortocoronary bypass or both combined within 1-4 days after anesthesiological/PBM clinic * for Group A: diagnosed anemia (hemoglobin levels below 13g/dL in men and 12g/dL in women) and iron-deficiency (transferrin saturation below 20% or ferritin serum level below 300μg/L), treatment with 500mg of ferric carboxymaltose (FerInject® 50 mg/ml, 10 ml, Vifor Pharma Group, Switzerland).

Exclusion criteria

* contraindication for intravenous iron therapy: severe infections, hepatocellular carcinoma, liver metastases, acute severe asthma, a simultaneous oral iron medication, another intravenous iron preparation, iron overload, chronic renal failure with regular intravenous iron substitution during dialysis treatment, age ≤18 years, pregnancy, lactation and being allergic to iron * elevated C-reactive protein (CRP) and leukocyte levels (cut-off level for leucocytes for men was \<10.9x10\^3/μl and for women \<12.68x10\^3/μl, respectively)

Design outcomes

Primary

MeasureTime frameDescription
Ferric Carboxymaltose levels (µg/mL)day of surgery to seven days after surgeryFerric Carboxymaltose levels in samples withdrawn from patient's blood, red blood cell concentrate of Cell Saver, heart-lung machine and washing solution prior to and after surgical procedure (µg/mL-Ferric carboxymaltose/plasma volume)

Secondary

MeasureTime frameDescription
Donor red blood cell concentratesBeginning till end of surgeryAdditional substitution of donor red blood cell concentrates
Ferritin (ng/ml)prior to intravenous iron supplementationFerritin levels before intravenous iron supplementation
Hemoglobin levels (mg/dl)prior to intravenous iron supplementation, 1 to 4 days prior to surgeryDelta Hemoglobin levels between prior to IV iron substitution until surgery
Intraoperative blood loss (ml)Beginning till end of surgeryBlood volume lost while surgical procedure
Blood volume balance (ml)Beginning till end of surgeryDelta of intraoperatively given (infusions, transfusions) and lost (bleeding, withdrawn from heart-lung machine) volumes

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026