Skip to content

AutoDx-DR Prospective Clinical Validation Study Protocol

An Evaluation of the Accuracy of AutoDx-DR, a Software Algorithm That Detects Diabetic Retinopathy From Retinal Images of Individuals With Diabetes

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04627272
Enrollment
1539
Registered
2020-11-13
Start date
2020-12-01
Completion date
2021-07-31
Last updated
2020-11-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetic Retinopathy

Keywords

Diabetic Retinopathy

Brief summary

In this study, we will prospectively evaluate the accuracy of a deep-learning based software algorithm in the detection of diabetic retinopathy from 60° wide single-field retinal fundus images.

Detailed description

We will obtain 60° wide single-field retinal fundus images from subjects who are diabetic patients in primary care environments (i.e. non-eye care settings, such as internal medicine, family medicine, and endocrinology). The fundus images will be uploaded to the RetinaVue Network software using the AutoDx-DR with Over-read modality, where images are transmitted to both AutoDx-DR and a remote ophthalmologist. AutoDx-DR will generate an initial Refer or Not Refer recommendation and the remote ophthalmologist will provide a detailed diagnostic image interpretation which will be used for patient management and referral during the course of the study. AutoDx-DR can also generate a third output which is Inadequate for Interpretation. In this case, the images will still be sent to the remote ophthalmologist for interpretation. If the ophthalmologist also cannot interpret the images, the patient will be recommended to have an in-person comprehensive ophthalmologic exam. Subjects participating in this study will undergo further retinal fundus imaging: four mydriatic, stereoscopic 45° field of view (4W) retinal images and spectral domain optical coherence tomography (SD-OCT) captured with the Reference Standard Camera (i.e. Zeiss Cirrus 600 photo, or other appropriate FDA-cleared imaging device with stereo fundus photography and SD-OCT capability that meets the requirements of the certified fundus photography reading center such as Topcon, Optovue, and Heidelberg). The 4W and SD-OCT imaging will be performed by a certified technician located at or near the enrolling study site. The 4W and SD-OCT images will be interpreted by a certified fundus photography reading center (FPRC) for more than mild DR or any diabetic macular edema. The FPRC's Not Refer/Refer determination will be used as the gold standard interpretation in this study. The AutoDx-DR interpretation of the 60° wide single-field images will be compared to the FPRC gold standard interpretation for the Not Refer/Refer recommendation. Accuracy metrics of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR), with 95% confidence intervals will be calculated. All diabetic patients who are attending routine primary care or endocrinology appointments and meet the enrollment criteria will be invited to participate in the study. All study procedures will be performed during a single study visit.

Interventions

DEVICEAutoDX-DR

AutoDx-DR provides basic image interpretation for the detection of DR and diabetic macular edema (DME) and a Refer or Not Refer recommendation.

Sponsors

Rho, Inc.
CollaboratorINDUSTRY
ClinEdge
CollaboratorINDUSTRY
Hill-Rom
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

This is a study to determine the accuracy of AutoDX. All eligible study participants will have a retinal fundus image taken which is then uploaded to the RetinaVue Network. Subjects will also undergo further retinal fundus imaging: four mydriatic, stereoscopic 45° field of view (4W) retinal images and spectral domain optical coherence tomography (SD-OCT) captured with the Reference Standard Camera.

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
No

Inclusion criteria

A documented diagnosis of diabetes mellitus in accordance with the criteria established by the American Diabetes Association (ADA)7 as indicated by at least one of the following: * Hemoglobin A1c (HbA1c) \> 6.5% * Fasting Plasma Glucose (FPG; period of fasting must be at least 8 hours) \> 126 mg/dL (7.0 mmol/L) * Oral Glucose Tolerance Test (OGTT) with 2-hour plasma glucose \>200 mg/dL (11.1 mmol/L), using the equivalent of an oral 75 g anhydrous glucose dose dissolved in water o Symptoms of hyperglycemia or hyperglycemic crisis with a random plasma glucose (RPG) ≥ 200 mg/dL (11.1 mmol/L) * 22 years of age or older * Ability to understand the study and sign the informed consent

Exclusion criteria

* A documented diagnosis of more than mild diabetic retinopathy in the patient record. o More than mild diabetic retinopathy shall be defined as moderate NPDR, severe NPDR, proliferative diabetic retinopathy (PDR) or any level of DME; or a documented diabetic eye exam report indicating more than microaneurysms \[i.e. presence of intraretinal hemorrhages, venous beading, intraretinal microvascular abnormalities (IRMA,) neovascularization or DME.\] * They report having severe vision loss in both eyes. * They report a history of laser treatment or surgery of the retina. * They report that they are currently receiving treatment for DR or DME. * They report a diagnosis of angle closure glaucoma. * They report hypersensitivity to light which makes retinal imaging uncomfortable. * They are currently pregnant or breastfeeding. * They report that they have an iris supported intraocular lens or anterior chamber intraocular lens associated with a previous cataract surgery. * They had a previous pupilloplasty surgery.

Design outcomes

Primary

MeasureTime frameDescription
SensitivityEach subject will only have one day study visit and will provide the AutoDX-DR and gold standard reading during their one visit.The ability of AutoDX-DR to correctly identify those with the disease (true positive rate)
SpecificityEach subject will only have one day study visit and will provide the AutoDX-DR and gold standard reading during their one visit.The ability of AutoDX-DR to correctly identify those without the disease (true negative rate)

Contacts

Primary ContactElizabeth Downs
Elizabeth.Downs@hillrom.com9893394131
Backup ContactLindsay E Downing
lindsay.downing@hillrom.com8043070924

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026