EO Footprint as a Landmark During DAA THA

The External Obturator Footprint as a Landmark for Stem Dept - Clinical Validation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04623073
Enrollment
135
Registered
2020-11-10
Start date
2021-01-01
Completion date
2021-04-29
Last updated
2024-06-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coxarthrosis

Keywords

Total hip Arthroplasty, leg length, templating, direct anterior approach, external obturator footprint

Brief summary

One of the goals of Total Hip Arthroplasty (THA) is to reconstruct leg length as adequately as possible. In order to achieve this one needs landmarks that are visible both on the templating X ray as well as during surgery. The classical posterior and lateral approaches often rely on the distance from the greater trochanter (GT) to the shoulder of the femoral stem or the distance from the lesser trochanter (LT) to the side of the neck osteotomy. If the surgeon finds out on the digital template that the distance from the GT to the shoulder of the implant should be X mm to achieve equal leg length, than the surgeon can try to reconstruct this during surgery. During the Direct Anterior Approach (DAA) these landmarks usually are not visible or require additional dissection injuring important soft tissue structures along the way. One anatomical structure that appears to be always visible during the DAA is the External Obturator tendon (EO). It was recently confirmed that the level of insertion of the EO onto the proximal femur can also always be determined on pre-operative X rays. It therefore represents one of the few landmarks that is visible both on the templating X ray as well as during DAA THA. Indeed, many hip surgeons, including ourselves, believe that if the shoulder of the femoral stem is near the insertion of the EO leg length cannot be far off. However, there is no clinical data to support this. The investigators would therefore like to the correlate the distance observed intra-operatively to the actual established distance on the post-operative X ray.

Interventions

PROCEDURETotal Hip arthroplasty via a Direct Anterior Approach

Total Hip arthroplasty via a Direct Anterior Approach

Sponsors

Universitaire Ziekenhuizen KU Leuven
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* All patient who underwent THA via DAA by a single surgeon who routinely documents the distance from the shoulder of the stem to the upper border of the EO tendon

Exclusion criteria

* Distance not noted * No radiographs available

Design outcomes

Primary

MeasureTime frame
Correlation between the distance measured intra-operatively and presumed distance on the pelvic radiographs2 days

Secondary

MeasureTime frame
Visibility of the EO tendon intra-operatively2 days
Inter and intra-rater reliability2 days