Diffusion-Weighted MRI for Breast Cancer Screening in Women With a Personal History of Breast Cancer

Comparison of Diffusion-Weighted MRI and Mammography Alone or Combined Mammography and Ultrasonography for Screening Women With a Personal History of Breast Cancer (DIMRISC-2 Study)

Status
Suspended
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04619186
Enrollment
1694
Registered
2020-11-06
Start date
2024-12-30
Completion date
2026-12-30
Last updated
2024-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Cancer

Brief summary

Women with personal history of breast cancer (PHBC) are at risk of developing second breast cancers in the conserved and contralateral breast. Because early detection of second breast cancers at the asymptomatic phase can improve relative survival by 17-28%, guidelines recommend annual mammography screening in women with PHBC. However, lower sensitivity and higher interval cancer rates are observed in women with a PHBC compared with women without, especially in women 50 years or younger and those with dense breasts. In a multicenter comparison study of 754 women, MRI screening detected 3.8 additional cancers and ultrasonography detected 2.4 additional cancers, and increased sensitivity over mammography alone. However, the use of breast MRI is limited not only by high costs and long examination time but also by high false-positive findings. In addition, the use of intravenous gadolinium-based contrast agent is contraindicated in women with renal impairment or contrast material allergy contrast. Supplemental ultrasonography in patients with PHBC reports lower sensitivity with high interval cancer rate. Thus, there is a need to develop a more safe, accurate, and cost-effective supplemental imaging modality for screening in women with PHBC. Diffusion-weighted (DW) MRI is an unenhanced fast, functional modality that measures the movement of water molecules to create tissue contrast. Breast malignancies exhibit hindered diffusion and appear hyperintense on DW MRI with low apparent diffusion coefficient (ADC) compared to normal surrounding tissue. Multiple studies have shown that the use of DW MRI can significantly reduce the false positives and unnecessary benign biopsy of breast MRI. Several studies have shown that DW MRI has a potential to detect mammography occult breast cancers with less false positives compared to ultrasonography. These observations have led to the consideration of utilizing DW MRI to screen women with PHBC. In Diffusion-weighted MRI for Breast Cancer Screening (DIMRISC-2) study, we hypothesized that the screening performance of high-resolution DW MRI at 3.0 T should be superior to mammography alone or combined mammography and ultrasonography in women with PHBC. In our institution, alternating conventional imaging and DW MRI screening is offered for patients who have undergone breast surgery and at increased risk of an interval second breast cancer.

Detailed description

* Primary objective: to compare the screening performance of DW MRI versus mammography alone or combined mammography and ultrasonography in women with PHBC. * Secondary objective: to compare the tumor and patient characteristics detected by DW MRI and combined mammography and ultrasonography in women with PHBC. * This is a prospective, single center, observational cohort study. * A total of 1694 women will be enrolled in this study. * Two latest 3.0 T MRI scanners with dedicated 16- or 18-channel bilateral breast coil are used for DW MRI. For DW MRI screening, the high-resolution echo-planar imaging sequence is designed to have an in-plane resolution of 1.3 x 1.3 mm and a slice thickness of 3 mm. Three b values of 0, 800, and 1200 sec/mm2 are used and ADC maps are generated based on the b=0 and 800 sec/mm2 DW MRI data. The DW MRI images are reconstructed into single summation images with maximum-intensity projections (MIPs) in the sagittal and axial planes. In addition, T1-weighted imaging sequence is also obtained with in-plane resolution of 1.0 x 1.0 mm and a slice thickness of 1 mm. * All patients with PHBC undergo digital two-dimensional mammography and physician-performed whole-breast ultrasonography on the same day. DW MRI and conventional imaging (mammography and ultrasonography) are alternatively scheduled at 6-month intervals and the order has been randomized. * Mammography alone, combined mammography and ultrasonography, and DW MRI will be interpreted independently according to the Breast Imaging Reporting and Data System (BI-RADS) and likelihood of malignancy (Score range, 0%-100%) by trained radiologists. DW MRI interpretation guidelines to be used in this study are based on both qualitative and quantitative assessments. Radiologists are required to successfully complete a training case series of 100 DW MR studies prior to interpreting the DW MRI. * A negative examination result is defined as a final assessment BI-RADS category of 1, 2, 3 and a positive examination result is defined as a final assessment BI-RADS category of 4 or 5. * Biopsies of DW MRI-detected lesions are performed under ultrasonography guidance whenever possible or with MR guidance if there is no correlative ultrasonography finding. Pathology of core or surgical biopsy and 1 year follow up is the reference standard.

Interventions

None listed

Sponsors

Seoul National University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
25 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Women over 25 years of age at the time of enrollment 2. Women who underwent breast conservation therapy or mastectomy and at increased risk of an interval second breast cancer (Age \<50 at first cancer diagnosis; Breast density BI-RADS category 3 and 4; First degree family history; First breast cancer was an interval cancer or symptomatic presentation; First breast cancer was grade 2, 3 or ER and PR negative)

Exclusion criteria

1. Women with signs or symptoms of breast cancer 2. Women who had bilateral mastectomy 4\. Women who had known metastatic disease 5. Pregnant or lactating women 6. Women with claustrophobia or metallic foreign body

Design outcomes

Primary

MeasureTime frameDescription
Cancer detection rate (CDR)Baseline to up to 1 yearNumber of detected cancers (invasive cancer and DCIS) /1000 women

Secondary

MeasureTime frameDescription
SpecificityBaseline to up to 1 yearNumber of negative examinations without tissue diagnosis of cancer within 1 year/All examinations without tissue diagnosis of cancer within the same period
Recall rateBaseline to up to 1 yearPercentage of women screened with recommendation for further imaging prior to next routine examination
Positive predictive value (PPV)Baseline to up to 1 yearPPV1: True positive/True positive + False positive * PPV2: Number of biopsy confirmed cancers/total number of recommendations for biopsy. * PPV3: Number of biopsy confirmed cancers/total number of biopsies performed
SensitivityBaseline to up to 1 yearNumber of positive examinations with a tissue diagnosis of cancer within 1 year/All examinations with tissue diagnosis of cancer within the same period
Interval cancer rateBaseline to up to 1 yearBreast cancer diagnosed within 1 year of a negative screening result because of clinical symptoms/1000 women
Characteristics of detected cancersBaseline to up to 1 yearTumor size, type, grade, molecular subtype, and lymph node metastasis
Characteristics of women with DW-MRI detected cancerBaseline to up to 1 yearAge, menopausal status, breast density, family history
AccuracyBaseline to up to 1 yearProportion of true positive results (both true positive and true negative) in the population -The area under the (receiver operating characteristic) curve (AUC)

Countries

South Korea

Outcome results

None listed