Skip to content

The PROTEMBO C Trial

Cerebral Protection in Transcatheter Aortic Valve Replacement - The PROTEMBO C Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04618718
Enrollment
64
Registered
2020-11-06
Start date
2020-07-31
Completion date
2022-11-23
Last updated
2025-05-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Valvular Heart Disease

Keywords

TAVR, cerebral embolic protection

Brief summary

The PROTEMBO C Trial is an international, multi-center, single arm, non-inferiority study of the safety and performance of using the ProtEmbo System for cerebral embolic protection in subjects with severe native aortic valve stenosis indicated for TAVR.

Interventions

DEVICEcerebral embolic protection during TAVR

The ProtEmbo system is an adjunctive device placed in the central arterial system at the beginning of a TAVR procedure to deflect embolic particles during the procedure and removed following the completion of the procedure.

Sponsors

Avania
CollaboratorINDUSTRY
Protembis GmbH
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. The heart team recommends transcatheter valve aortic valve replace consistent with the 2017 ESC/EACTS Guidelines for the management of valvular heart disease. 2. Compatible left subclavian artery (≥ 4 mm diameter) without significant stenosis (\> 70%) and distance between the origin of left subclavian artery and valve plain of ≥ 90mm as determined by Multi-Slice Computed Tomography (MSCT) scan or equivalent imaging modality. 3. The subject and the treating physician agree that the subject will undergo the scheduled pre-procedural testing and return for all required post-procedure follow-up visits. 4. The subject is able to provide informed consent, has been informed of the nature of the trial, agrees to its provisions and has provided written informed consent as approved by the relevant regulatory authority of the respective clinical site. 5. Subject is a minimum of 18 years of age.

Exclusion criteria

General: 1. Left upper limb vasculature in the left extremity precluding 6Fr sheath radial / brachial / subclavian access. 2. Inadequate circulation to the left extremity as evidenced by signs of artery occlusion (modified Allen's test) or absence of radial/brachial pulse. 3. Hemodialysis shunt, graft, or arterio-venous fistula involving the upper extremity vasculature. 4. TAVR conducted via other than transfemoral access (subclavian, axillar, transapical, transaortic, carotid or transcaval). 5. Evidence of an acute myocardial infarction ≤ 1 month before the intended treatment. 6. Aortic valve is a congenital unicuspid or bicuspid valve. 7. Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation \>3+). 8. Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days of the index procedure (unless part of planned strategy for treatment of concomitant coronary artery disease). 9. Blood dyscrasias as defined: Leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis or coagulopathy. 10. Hemodynamic instability requiring inotropic support or mechanical heart assistance. 11. Need for emergency surgery for any reason. 12. Severe hypertrophic cardiomyopathy with or without obstruction. 13. Severe ventricular dysfunction with LVEF ≤30%. 14. Echocardiographic evidence of intracardiac or aortic mass, thrombus, or vegetation. 15. Symptomatic or asymptomatic severe (≥ 70%) occlusive carotid disease requiring concomitant CEA / stenting. 16. Subject has undergone carotid stenting or carotid endarterectomy within the previous 6 weeks. 17. Active peptic ulcer or upper GI bleeding within the prior 6 months. 18. A known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, or clopidogrel, device component material, or sensitivity to contrast media, which cannot be adequately premedicated. 19. Recent (within 6 months) CVA or a TIA. 20. Renal insufficiency (creatinine \> 3.0 mg / dL or GFR \< 30) and / or renal replacement therapy at the time of screening. 21. Life expectancy \< 12 months due to non-cardiac co-morbid conditions. 22. Subjects in whom anti-platelet and / or anticoagulant therapy is contraindicated, or who will refuse transfusion. 23. Subjects who have active bacterial endocarditis or other active infections. 24. Currently participating in an investigational drug or another device study. 25. Subjects who have a planned treatment with any other investigational device or procedure during the study follow-up period (30 days). 26. Subjects with planned concomitant surgical or transcatheter ablation for Atrial Fibrillation during the study follow-up period (30 days). 27. Any subject with a balloon valvuloplasty (BAV) within 30 days of the procedure. 28. Subject is a woman of child-bearing potential. 29. Patient with Heparin-Induced Thrombocytopenia Syndrome. 30. Inner diameter of aortic arch is less than 25mm. 31. Brachiocephalic trunk originating from the aortic arch that splits into the bilateral subclavian arteries and a bicarotid trunk (Origin D). 32. Hepatic failure (defined as liver enzyme elevations two times the upper limit of normal) or active infectious hepatitis 33. Cardiogenic shock or severe hypotension (systolic blood pressure \< 90 mm Hg) at the time of the index procedure 34. Subjects who have a planned concomitant cardiac surgical or interventional procedure (e.g., coronary revascularization) during the TAVI procedure 35. Subjects who have a pre-existing prosthetic heart valve in any position Neurological: 1. Subject had active major psychiatric disease. 2. Subject has severe visual, auditory, or learning impairment and is unable to comprehend English or local language and therefore unable to be consented for the study. 3. Subjects with neurodegenerative or other progressive neurological disease or history of significant head trauma followed by persistent neurologic defaults or known structural brain abnormalities. Angiographic: 1. Excessive tortuosity or severe peripheral arterial disease in the left radial / brachial / subclavian artery preventing ProtEmbo System access and insertion. 2. Subject whose left radial / brachial / subclavian artery reveals significant stenosis, calcification, ectasia, dissection, occlusion or aneurysm, in particular at or within 3 cm of the aortic ostium. 3. Subject with significant stenosis, ectasia, dissection, or aneurysm in the ascending aorta or in the aortic arch, or with abnormal aortic arch angulation or abnormal anatomical conditions of the aorta. Magnetic Resonance Imaging: 1. Subject Body Mass Index (BMI) precluding imaging in scanner. 2. Contraindications to MRI (subjects with any implantable temporary or permanent pacemaker or defibrillator, metal implants in field of view, metallic fragments, clips, or devices in the brain or eye before TAVR procedure). 3. Subjects who have a high risk of complete AV block after TAVR, with the need of permanent pacemaker (e.g. subjects with preexisting bifascicular block or complete right bundle branch block plus any degree of AV block). 4. Planned implantation of a pacemaker or defibrillator implantation within the first 4 days after TAVR. 5. Claustrophobia precluding MRI scanning. 6. No scanner hardware, software, coil or protocol changes during the course of the study.

Design outcomes

Primary

MeasureTime frameDescription
Rate of Participants With MACCE Events30 days post-procedureNumber of participants experiencing a Major Adverse Cardiac and Cerebrovascular Event (MACCE) defined by VARC-2 including all-cause mortality, all stroke, life-threatening or disabling bleeding, vascular injury and acute kidney injury (stage 2 or 3) within 30 days of the procedure
Rate of Participants in Whom Technical Success Was AchievedDuring the procedureNumber of participants in whom technical success was achieved during the procedure. Technical success is defined as the ability to safely deliver, deploy, and remove the device, ability to secure positioning and stability of the position throughout the transcatheter intracardiac procedure and ability to deflect embolic material as assessed by adequate coverage while not impeding blood flow, deployed and removed and positioning and stability of the device

Secondary

MeasureTime frameDescription
Efficacy-MR Imaging: Comparison Between the Median New Lesion Volume in the Brain2-7 days post-procedureComparison between the median new lesion volume in the brain assessed by diffusion weighted magnetic resonance images (DW-MRI) at 2-7 days and historical data; the total new lesion volume is defined as the sum of all diffusion-positive new cerebral lesions in post-procedural DW-MRI relative to the pre-TAVR DW-MRI
Composite Rate of Death or All Strokes3 days post-procedureDeath or all stroke according to VARC-2 criteria (to define occurrence and type stroke) within 3 days (72 hours) of the TAVR procedure compared to historical data

Countries

Germany, Latvia, Poland

Participant flow

Participants by arm

ArmCount
Intervention
ProtEmbo device will be used as distal protection device in subjects undergoing TAVR cerebral embolic protection during TAVR: The ProtEmbo system is an adjunctive device placed in the central arterial system at the beginning of a TAVR procedure to deflect embolic particles during the procedure and removed following the completion of the procedure.
64
Total64

Baseline characteristics

CharacteristicIntervention
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
63 Participants
Age, Categorical
Between 18 and 65 years
1 Participants
Age, Continuous79 years
STANDARD_DEVIATION 5.1
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
64 Participants
Region of Enrollment
Germany
20 participants
Region of Enrollment
Latvia
5 participants
Region of Enrollment
Poland
39 participants
Sex: Female, Male
Female
35 Participants
Sex: Female, Male
Male
29 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 64
other
Total, other adverse events
21 / 64
serious
Total, serious adverse events
20 / 64

Outcome results

Primary

Rate of Participants in Whom Technical Success Was Achieved

Number of participants in whom technical success was achieved during the procedure. Technical success is defined as the ability to safely deliver, deploy, and remove the device, ability to secure positioning and stability of the position throughout the transcatheter intracardiac procedure and ability to deflect embolic material as assessed by adequate coverage while not impeding blood flow, deployed and removed and positioning and stability of the device

Time frame: During the procedure

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
InterventionRate of Participants in Whom Technical Success Was Achieved57 Participants
Primary

Rate of Participants With MACCE Events

Number of participants experiencing a Major Adverse Cardiac and Cerebrovascular Event (MACCE) defined by VARC-2 including all-cause mortality, all stroke, life-threatening or disabling bleeding, vascular injury and acute kidney injury (stage 2 or 3) within 30 days of the procedure

Time frame: 30 days post-procedure

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
InterventionRate of Participants With MACCE Events3 Participants
Secondary

Composite Rate of Death or All Strokes

Death or all stroke according to VARC-2 criteria (to define occurrence and type stroke) within 3 days (72 hours) of the TAVR procedure compared to historical data

Time frame: 3 days post-procedure

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
InterventionComposite Rate of Death or All Strokes1 Participants
Secondary

Efficacy-MR Imaging: Comparison Between the Median New Lesion Volume in the Brain

Comparison between the median new lesion volume in the brain assessed by diffusion weighted magnetic resonance images (DW-MRI) at 2-7 days and historical data; the total new lesion volume is defined as the sum of all diffusion-positive new cerebral lesions in post-procedural DW-MRI relative to the pre-TAVR DW-MRI

Time frame: 2-7 days post-procedure

ArmMeasureValue (MEDIAN)
InterventionEfficacy-MR Imaging: Comparison Between the Median New Lesion Volume in the Brain210 mm3

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026