Skip to content

Wireless US-guided CVC Placement in Infants

Performing Central Venous Catheters in Neonates and Small Infants Undergoing Cardiac Surgery Using a Wireless Transducer for Ultrasound Guidance: a Prospective, Observational Pilot Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04597021
Enrollment
30
Registered
2020-10-22
Start date
2018-08-01
Completion date
2019-01-30
Last updated
2020-10-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Central Venous Catheter, Congenital Heart Disease in Children, Wireless Ultrasound

Brief summary

Background: Neonates and small infants with congenital cardiac disease undergoing cardiac surgery represent major challenges facing pediatric anesthesia and perioperative medicine. Aims: We here aimed to investigate the success rates in performing ultrasound guided central venous catheter insertion (CVC) in neonates and small infants undergoing cardiac surgery, and to evaluate the practicability and feasibility of thereby using a novel wireless ultrasound transducer (WUST). Methods: Thirty neonates and small infants with a maximum body weight of 10 kg and need for CVC before cardiac surgery were included in this observational trial and were subdivided into two groups according to their weight: \< 5 kg and ≥5 kg. Cannulation success, failure rate, essential procedure related time periods, and complications were recorded and the clinical utility of the WUST was assessed by a 5-point Likert scale.

Interventions

DEVICEuse of a wiresless US transducer

to (evaluate the practicability of applying a wireless US transducer for central venous catheter-placement in these patients.

Sponsors

Medical University of Vienna
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 2 Years

Inclusion criteria

neonates and small infants with a maximum body weight of 10 kg and need for insertion of a CVC before cardiac surgery at our institution

Exclusion criteria

* missing consent for study participation \>10 kg body weight * emergency surgery * central venous catheter in situ

Design outcomes

Primary

MeasureTime frameDescription
Rate of success using a wireless US for pediatric CVCduring cardiac surgeryClinical applicability of a wireless US transducer for CVC insertion for pediatric cardiac surgery

Countries

Austria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 21, 2026