Skip to content

Squeaking in Ceramic-on-Ceramic Total Hip Arthroplasty Using Delta TT Cup

Squeaking in Ceramic-on-Ceramic Total Hip Arthroplasty Using Delta TT Cup

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04594564
Enrollment
270
Registered
2020-10-20
Start date
2020-10-01
Completion date
2024-12-31
Last updated
2025-06-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Femoral Neck Fractures, Osteoarthritis, Hip, Osteonecrosis of Femoral Head, Posttraumatic Arthropathy, Rheumatoid Arthritis of Hip

Keywords

Total hip arhtroplasty, Squeaking, Dislocation, Ceramic bearings

Brief summary

This study will evaluate clinical outcome on patients who undergo ceramic on ceramic (CoC) bearing total hip arthroplasty (THA) using Delta TT cup.

Detailed description

This study will evaluate clinical outcome on patients who undergo ceramic on ceramic (CoC) bearing total hip arthroplasty (THA) using Delta TT cup. Specifically the study intends to address the following research topics: 1. The incidence of squeaking after CoC THA using Delta TT cup. 2. The dislocation rate and survival rate of CoC THA using Delta TT cup.

Interventions

PROCEDURETotal hip arthroplasty with Delta TT cup

Total hip arthroplasty using Delta TT cup and ceramic bearings

Sponsors

LIMA Korea
CollaboratorUNKNOWN
Seoul National University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Older than 18 years old * Non-inflammatory degenerative joint disease such as osteoarthritis or avascular necrosis * Rheumatoid arthritis * Post-traumatic arthritis * Fractures of femoral neck

Exclusion criteria

* Local or systemic infection * Septicaemia * Persistent acute or chronic osteomyelitis * Confirmed nerve or muscle lesion compromising hip joint function * Unstable medical illness * Rapidly progressive neurological disease

Design outcomes

Primary

MeasureTime frameDescription
Squeaking6 weeksRate of any noise after THA

Secondary

MeasureTime frameDescription
Dislocation6 weeksDislocation rate after THA

Other

MeasureTime frameDescription
Range of motion24 monthsChange of range of motion after THA
Survivorship of implant24 monthsSurvival rate of prosthesis

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026