Skip to content

Evaluation of the Safety and Performance of the Very High Power-Short Duration QDOT

Evaluation of the Safety and Performance of the Very High Power-Short Duration QDOT Strategy in Patients Referred for Atrial Fibrillation Ablation.

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04592497
Enrollment
60
Registered
2020-10-19
Start date
2020-10-15
Completion date
2022-10-01
Last updated
2020-10-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Brief summary

The aim of the present study is to compare the safety and short-term performance between THERMOCOOL SMARTTOUCH SF-5D QDOT system used with fast ablation mode and the standard Thermocool Smartouch SF in treatment of patients with atrial fibrillation (AF).

Detailed description

The very high power-short duration (vHPSD) catheter, is a novel CF catheter optimized for temperature-controlled ablation with microelectrodes and 6 thermocouples for real-time temperature monitoring during ablation. The associated vHPSD algorithm modulates power to maintain target temperature during these vHPSD lesions (90 W, 4 s). In preclinical models, vHPSD ablation with this novel catheter has improved atrial linear lesion contiguity, transmurality, and durability and has substantially reduced radiofrequency ablation times, but with a safety profile similar to those of standard irrigated radiofrequency ablation catheters. The QDOT -FAST study demonstrated the clinical feasibility and safety of vHPSD ablation. Procedure and fluoroscopy times were substantially lower than historical standard ablation with point-by-point catheters. The aim of the present study is to compare the safety and short-term performance between THERMOCOOL SMARTTOUCH SF-5D QDOT system used with fast ablation mode and the standard Thermocool Smartouch SF in treatment of patients with atrial fibrillation (AF).

Interventions

PROCEDUREAF ablation

Prospective, single-center, non-randomized, open label, two arm study. After informed consent, 60 consecutive subjects who are scheduled to undergo AF ablation will be enrolled in the study in two equally sized groups of 30 subjects each. One group will undergo the procedure with assistance THERMOCOOL SMARTTOUCH SF-5D QDOT system and the other with the standard Thermocool Smartouch SF system. Data will be collected from all subjects during the ablation procedure and post procedure for a period of 12 months. Data will be anonymized by removing patient protected health information, only initials will be used.

Sponsors

Tel-Aviv Sourasky Medical Center
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and female \>18 years old. * Subjects must provide written informed consent to participate in the study. * Subject is willing to comply with the protocol requirements and return to the treatment center for all required clinical evaluations.

Exclusion criteria

* Pregnant women. * Patients with iodine contrast media allergy * Patients with renal failure (GFR \<60ml/min)

Design outcomes

Primary

MeasureTime frameDescription
procedure time1 dayThe procedural and fluoroscopy time required for the procedure (in minutes).
isolation efficacy1 dayThe first time pulmonary vein isolation (percentages of success)
Recurrence of AF1 yearRecurrence of AF (will be assessed by Holter monitoring)