Skip to content

Feasibility of the Mi2000 Totally Implantable Cochlear Implant in Severely to Profoundly Deaf Adults.

Feasibility Study: A Totally Implantable Cochlear Implant (Mi2000) for Electrical Stimulation of the Auditory Pathway of Adults With Severe to Profound Sensorineural Hearing Loss

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04571333
Acronym
TICI
Enrollment
6
Registered
2020-10-01
Start date
2020-09-07
Completion date
2021-12-31
Last updated
2024-10-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cochlear Implants, Sensorineural Hearing Loss, Bilateral

Brief summary

This clinical investigation aims to collect data on the use of the Mi2000 system, a totally implantable cochlear implant system, for the first time in human subjects.

Detailed description

Cochlear implants (CI) provide a large majority of recipients with a significant degree of speech understanding. However, CI systems rely on external parts, namely Behind-the-Ear (BTE) audio processors with coils or single-unit processors to function. This can have several disadvantages: for instance, the hardware is exposed to external trauma and to the effects of head movement and gravity. The device is also put at risk by humid, dusty, or dirty conditions as well as by physical activities that lead to water exposure such as swimming or sports in general (e.g. perspiration). In addition, some patients are concerned with the cosmetic appearance of the external parts which are visible (more so than modern behind-the-ear hearing aids), something that may not be desirable to many potential candidates. This clinical investigation aims to collect data on the use of the Mi2000 system, a totally implantable cochlear implant system, for the first time in human subjects.

Interventions

DEVICEMi2000 Totally Implantable Cochlear Implant

During the surgery visit, the Mi2000 Cochlear Implant will be implanted according to the general surgical guidelines and the Mi2000 specific surgical guidelines under general anaesthesia.

Sponsors

MED-EL Elektromedizinische Geräte GesmbH
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Minimum age of eighteen (18) years at time of enrolment * Bilateral sensorineural hearing loss with no or limited benefit from a hearing aid (\>70 dB HL PTA4) * Post-lingual onset of deafness * No or limited benefit from hearing aids for less than 10 years. * A maximum score of 50% on a monosyllables test in the language of the test centre in the ear to be implanted * General health condition, psychological and emotional condition deemed compatible with the treatment and tests performed in this study and realistic expectations, as deemed appropriate by the implanting surgeon/implant board * Fluency in the test language with excellent proficiency, as appropriate to perform speech testing * Evidence of up-to-date vaccinations against meningitis, as per recommendations by the applicable national body * Signed and dated informed consent before the start of any study-specific procedure

Exclusion criteria

* Lack of compliance with any inclusion criterion * Previously having received an implant on the location chosen for placing the cochlear implant * Having received a hearing implant from another manufacturer than MED-EL on the contralateral ear * Pre-existing condition known to necessitate MRI scans after implantation of the Mi2000 * Women being pregnant or nursing * Women of child-bearing age not reporting to use effective contraception * Contraindication to surgery in the middle and inner ear * Contraindication to general anaesthesia * Cochlear malformations, ossification or other obliteration of the cochlea, history of meningitis preventing placement of the electrode array, as confirmed by medical examination * Acute cholesteatoma * Acute external or middle ear infections * Perforated tympanic membrane * Known intolerance to any of the materials used for the implant or accessories * Non-functional auditory nerve and/or upper auditory pathway including a history of vestibular schwannoma * Factors preventing appropriate placement of the stimulator housing and the microphone, including fixation with screws, in the bone of the skull * Unstable Meniere's disease, Auditory Neuropathy, Epilepsy not responding to treatment * Unrealistic expectations of the subject * Permanent inability and/or unwillingness to participation in post-operative care and rehabilitation * Known intellectual disability and/or psychological diseases * Participation in other pharmacological clinical trials within four weeks prior to enrolment

Design outcomes

Primary

MeasureTime frameDescription
Safety of the study deviceup to 16 weeksSafety of the study device in the intended population will be assessed by an analysis of adverse events (AEs) reported

Secondary

MeasureTime frameDescription
Auditory Nerve Response Telemetry (ART)up to 52 weeksAuditory Nerve Response Telemetry (ART)
Safety of the study deviceup to 52 weeksSafety of the study device in the intended population will be assessed by an analysis of adverse events (AEs) reported
Speech perception in quietup to 52 weeksSpeech perception in quiet will be assessed with a monosyllables test
Speech perception in noiseup to 52 weeksSpeech perception in noise will be assessed with a sentence test in noise
Audiogramsup to 52 weeksAudiograms will be recorded in unaided and in best aided condition
Impedance Field Telemetryup to 52 weeksImpedance Field Telemetry (PIFT)
Questionnaire on usability of the deviceup to 52 weeksDevice use will be assessed using a questionnaire, recording user feedback
Health Utilities Index 2/3 (HUI2/3)up to 52 weeksQuality of life will be assessed by the HUI2/3 questionnaire
Speech, Spatial and Qualities of Hearing (12 item version) (SSQ12)up to 52 weeksQuality of life will be assessed by hte SSQ12 questionnaire
Nijmegen Cochlear Implant Questionnaire (NCIQ)up to 52 weeksQuality of life will be assessed by the NCIQ questionnaire
Sound quality ratingsup to 52 weeksSubjective rating of sound quality
Hardware and device parameters stored in the internal memoryup to 52 weeksReadout of device parameters stored in the devices internal memory (e.g. log files, battery status, charging status, usage times)

Countries

Belgium, Germany

Outcome results

None listed