Skip to content

Non Enhanced Labyrinth Imaging for the Detection of Endolymphatic Hydrops in Meniere's Disease "NELI Study"

Non Enhanced Labyrinth Imaging for the Detection of Endolymphatic Hydrops in Meniere's Disease "NELI Study"

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04569175
Acronym
NELI
Enrollment
14
Registered
2020-09-29
Start date
2020-11-06
Completion date
2022-04-05
Last updated
2026-06-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Meniere Disease

Keywords

Meniere's disease, NE 3D FLAIR sequence

Brief summary

This study includes 30 patients with Meniere's disease confirmed with AAO-HNS criteria. The aim of this study is to compare the new optimized 3D FLAIR sequence developed at our site with a standard 3D FLAIR sequence performed 4h after a single intravenous dose of macrocyclic gadolinium-based contrast agents for the detection of endolymphatic hydrops. The patients will be explored with the new 3D FLAIR optimized sequence before injection (method to validate) and again 4 hours after contrast media administration with the same sequence 3D FLAIR

Detailed description

Meniere's disease (MD) is a pathology of the inner ear defined by episodes of spontaneous vertigo usually accompanied by tinnitus, pressure within the ear and fluctuating sensorineural hearing loss. Endolymphatic hydrops (EH) is the main pathophysiological substratum of Meniere's disease. Temporal bone MRI has long been used performed to exclude other pathologies mimicking MD, such as vestibular schwannoma or endolymphatic sac tumor. Currently, delayed 3D-FLAIR sequence is the imaging technique of choice for the diagnosis of endolymphatic hydrops. The endolymphatic space could be assessed on MRI with 3D-FLAIR sequences delayed acquisition after the intravenous administration of gadolinium. The saccule appears to be the most involved structure in MD. The reproducibility of the hydrops protocols with various MRI scan manufacturers is debatable. Because endo and peri lymphatic spaces have different biochemical compositions, a new FLAIR 3D sequence on healthy volunteers can be tuned in order to separate endo and peri lymphatic spaces. The hypothesis of the study is that this new method could detect saccular hydrops with the same performances as the standard FLAIR that is done after gadolinium injection. This study will prospectively include 30 patients with MD confirmed with AAO-HNS criteria . All patients will sign an informed consent. They will be explored with the new 3D FLAIR optimized sequence without injection (method to validate). Then, they will be injected, and they will be explored again 4 hours after contrast product administration with the same sequence (the reference method),to take advantage of the intravenous injection of gadolinium that will be performed in the care. The optimized non enhanced 3D FLAIR sequence will be compared with the reference method and with the same sequence four hours after gadolinium injection.

Interventions

OTHER3D Flair sequence

Optimized 3D FLAIR sequence before and 4 hours after the usual care MRI (with contrast product). All patients will have the same intervention as each patient is its own control

Sponsors

University Hospital, Bordeaux
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Man or woman * older than 18 years old. * Uni- or bilateral definite or probable clinical diagnosis of MD based on the AAO-HNS guidelines revised in 2015. * Patient eligible for having contrast-enhanced MRI. * Patient affiliated of beneficiary of health insurance * Patient has signed the Informed consent form. Non inclusion criteria: * History of other pathology of the inner ear. * History of surgery on the middle or inner ear (tympanoplasty, endolymphatic sac drainage, vestibular schwannoma). * Pregnant (contraceptive method, HAS criteria) or nursing mothers * Contraindications to performing MRI (pace maker, metallic shards, claustrophobia) * Contraindications (relative) to injecting gadolinium (severe renal failure due to the risk of systemic nephrogenic fibrosis, history of allergic reaction) * Patient under legal protection

Design outcomes

Primary

MeasureTime frameDescription
Kappa coeficient1 hour before baseline (usual care MRI)the non-inferiority of the non-enhanced Flair sequence compared to the reference technique by indirect comparison with the reference method (Kappa coefficient \> or equal to 0.81).

Secondary

MeasureTime frameDescription
inter-observer correlation1 hour before baseline, baseline, 4 hours after baselineinter-observer correlation coefficient (weighted Kappa).

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 2, 2026