Skip to content

Diastolic Performance and Norepinephrine in Spinal-Induced Hypotension for Cesarean Delivery

Influence of Diastolic Performance on the Response to Norepinephrine for Prevention of Spinal Anesthesia-Induced Hypotension for Cesarean Delivery and Fetal Wellbeing

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04560634
Acronym
NORA-CS
Enrollment
40
Registered
2020-09-23
Start date
2020-01-14
Completion date
2020-12-15
Last updated
2021-11-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypotension

Keywords

norepinephrine, Cesarean section, spinal anesthesia

Brief summary

Background and rationale: The best agent to prevent spinal-induced hypotension is still uncertain but norepinephrine showed fewer effects on heart rate and cardiac output. In septic patients norepinephrine has been shown to produce an endogenous fluid challenge. Objective: We aim to assess if patients with impaired diastolic function (46% of pregnant women at term) are less able to maintain indexed cardiac output in response to norepinephrine infusion during spinal-induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery. Methods: We will assess by echocardiogram the diastolic function before surgery and will then start continuous non-invasive hemodynamic monitoring with a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) and perform a fluid challenge to relate diastolic disfunction with fluid responsiveness. Hemodynamic monitoring will continue throughout the surgery. Norepinephrine infusion will start concomitantly to beginning of spinal anesthesia and will stop 5 minutes after uterotonic medication. Outcome: We aim to assess if patients with diastolic disfunction are less able to maintain cardiac output in response to norepinephrine infusion during spinal anesthesia induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.)

Interventions

DRUGNorepinephrine

Norepinephrine is administered as a continuous infusion at 0.05 mcg/kg/min and is kept to maintain systolic blood pressure within 90-120% of baseline during spinal anaesthesia. The infusion is started at the same time cerebrospinal fluid is obtained, immediately before injection of spinal medications, through a small-bore tubing connected directly to the peripheral intravenous catheter. It is stopped 5 minutes

DEVICEClearSight®, Edwards Lifescience, Irvine, CA

All patients are connected to a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) by an inflatable finger cuff placed on the midphalanx of hand middle or ring finger with no radial artery catheter and its heart reference system (HRS) is zeroed at the level of the patient's midaxillary line. The ClearSight® monitoring is started in the pre-anaesthesia room and calibrated for 5 minutes before recording. The monitoring continues throughout the procedure until patient transfer in the recovery room. All data are anonymously collected on a USB pen for statistical analysis.

Sponsors

Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Pregnant women between the 36th and the 40th week of gestation undergoing spinal anesthesia for elective caesarian delivery.

Exclusion criteria

1. age \< 18 yo; 2. preeclampsia; 3. eclampsia; 4. atrial fibrillation and sinus tachycardia; 5. cardiovascular diseases; 6. neuromuscular disease; 7. emergent or urgent cesarean delivery; 8. coagulopathies; 9. contraindications to spinal anesthesia.

Design outcomes

Primary

MeasureTime frameDescription
Indexed Cardiac OutputBaseline/after spinal anesthesia/after deliveryWe aim to study if the diastolic performance of the heart measured by transthoracic echocardiography in healthy pregnant women at term undergoing spinal anesthesia for caesarean delivery influences the effects of norepinephrine on indexed cardiac output (CI) measured by non-invasive continuous hemodynamic monitoring.

Secondary

MeasureTime frameDescription
Indexed Stroke VolumeBaseline/after spinal anesthesia/after deliveryWe will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of indexed stroke volume (SVI) in ml, blood pressure (BP) in mmHg and heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring.
Systolic Blood PressureBaseline/after spinal anesthesia/after deliveryWe will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of blood pressure (BP) in mmHg measured by non-invasive continuous hemodynamic monitoring.
Heart RateBaseline/after spinal anesthesia/after deliveryWe will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring.
Apgar ScoresDecreases of Indexed Cardiac Output after spinal anesthesiaWe ought to correlate the reduction of neonatal Apgar Scores with decreases of indexed cardiac output measured by non-invasive continuous hemodynamic monitoring.

Countries

Italy

Outcome results

None listed