Skip to content

Intraintestinal Extended Biliary Stents Preventing Duodenobiliary Reflux in Patients With Biliary Stricture

Prevention of Duodenobiliary Reflux Via Intraintestinal Extended Biliary Stents in Patients With Biliary Stricture

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04550819
Enrollment
724
Registered
2020-09-16
Start date
2020-10-31
Completion date
2023-10-31
Last updated
2020-10-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bile Duct Stricture

Brief summary

Metal or plastic biliary stents placement under Endoscopic Retrograde Cholangiopancreatography(ERCP) is a well-established treatment for patients with benign biliary obstruction to relieve jaundice, a palliative treatment for patients with unresectable malignant pancreaticobiliary obstruction and a bridge to surgery for patients with resectable disease. The main limitation of long time plastic stents is stents occlusion. Biliary plastic stents are changed every 2 to 3 months due to an expected median patency from 77 to 126 days.Metal stents present a lower risk of recurring biliary occlusion, yet high cost and stents occlusion are eventually inevitable. The mechanism of biliary stents occlusion include biliary sludge of the accumulation of bacteria and duodenal biliary reflux .The anti-reflux barrier of Oddi's sphincter disappears after the insertion of biliary stents and the pressure in bile duct lowers the duodenale, which cause the retrograde flow of duodenal material into the biliary ducts. Besides, ordinary biliary plastic stent is short which can also shortens the length of duodenal biliary reflux . Therefore, trying to prevent the duodenal biliary reflux is very important in reducing biliary stents occlusion and it is gradually concerned by clinical researchers. Some studies have showed that plastic stents with antireflux valves can effectively reduce the biliary stent stricture and prolong the stents patency, which means reducing duodenobiliary reflux is surely useful for keeping biliary stent patency.So,we assume to explore an innovatively intraintestinal extended biliary stents (reformed with nasobiliary tube ) as substitution for ordinary biliary plastic stent to prevent the duodenobiliary reflux by extending the length of duodenal content reflux and avoid the stents shift via suspending in intrahepatic duct. In this study,we will design a multicenter stratified randomized controlled trial to compare the patency of intraintestinal extended biliary stents and ordinary plastic biliary stents in patients with malignant or benign biliary obstruction respectively and evaluate the effect of intraintestinal extended biliary stents for the prevention of duodenobiliary reflux.

Detailed description

Metal or plastic biliary stents placement under ERCP is a well-established treatment for patients with benign biliary obstruction to relieve jaundice, a palliative treatment for patients with unresectable malignant pancreaticobiliary obstruction and a bridge to surgery for patients with resectable disease. Single or multiple plastic stents are recommended for patients with benign stricture of the common bile duct or malignant stricture if the expected survival is less than 4 months. The main limitation of long time plastic stents is stents occlusion. Biliary plastic stents are changed every 2 to 3 months due to an expected median patency from 77 to 126 days.Metal stents present a lower risk of recurring biliary occlusion, yet high cost and stents occlusion are eventually inevitable. The mechanism of biliary stents occlusion include biliary sludge of the accumulation of bacteria and duodenal biliary reflux .The anti-reflux barrier of Oddi's sphincter disappears after the insertion of biliary stents and the pressure in bile duct lowers the duodenale, which cause the retrograde flow of duodenal material into the biliary ducts. Besides, ordinary biliary plastic stent is short which can also shortens the length of duodenal biliary reflux . Therefore, trying to prevent the duodenal biliary reflux is very important in reducing biliary stents occlusion and it is gradually concerned by clinical researchers. Some studies have showed that plastic stents with antireflux valves can effectively reduce the biliary stent stricture and prolong the stents patency, which means reducing duodenobiliary reflux is surely useful for keeping biliary stent patency.So,we assume to explore an innovatively intraintestinal extended biliary stents with length of 26cm (reformed with nasobiliary tube ) as substitution for ordinary biliary plastic stent to prevent the duodenobiliary reflux by extending the length of duodenal content reflux and avoid the stents shift via suspending in intrahepatic duct. In this study,we will design a multicenter stratified randomized controlled trial to compare the patency of intraintestinal extended biliary stents and ordinary plastic biliary stents in patients with malignant or benign biliary obstruction respectively and evaluate the effect of intraintestinal extended biliary stents for the prevention of duodenobiliary reflux. This prospective study will be performed at 6 tertiary hospitals in China.The investigators will recruit patients according to admission criteria and exclusion criteria.The patients stratified by malignant and benign biliary obstruction will be randomized (at a 1:1 ratio) to intraintestinal extended biliary stents group (experimental group) and ordinary plastic biliary stents group (control group).The experimental groups will be placed the intraintestinal extended biliary stents in intrahepatic bile duct in ERCP. The control group will be placed ordinary plastic biliary stents in ERCP. The primary endpoint is the duration of stent patency and the rate of stent occlusion.The secondary outcomes include the mortality of each group、adverse events and the rate of technical success.

Interventions

PROCEDUREintraintestinal extended biliary stents

The test group will be placed intraintestinal extended biliary stents in intrahepatic bile duct in ERCP

The test group will be placed ordinary plastic biliary stents in intrahepatic bile duct in ERCP

Sponsors

Peking University Third Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
DOUBLE (Subject, Caregiver)

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Malignant or benign extrahepatic biliary stricture,available for insertion of biliary stents in ERCP to alleviate biliary stricture

Exclusion criteria

* Patients with malignant or benign biliary stricture do not agree with endoscopic treatment * Patients agree with metal biliary stents * Patients with resectable biliary occlusion * A guidewire could not be passed through the stricture * Patients with an expected life survival \<3months * Patients with duodenal obstruction and duodenal endoscopy could not be reached to papillary

Design outcomes

Primary

MeasureTime frameDescription
the duration of stent patency and stent occlusion rate12 months after ERCPPatients with symptoms of cholangitis and worsening liver function tests suggestive of cholestasis are considered as premature stent occlusion.

Secondary

MeasureTime frameDescription
mortality of each group12 months after ERCPWe will compare the mortality of each group after the insertion of biliary stents.
adverse events12 months after ERCPAdverse events include complications of post ERCP such as pancreatitis,biliary infection, bleeding, perforation,and stent migration
the rate of technical success12 months after ERCPTechnical success is defined as successful insertion of the stent into the bile duct during ERCP

Countries

China

Contacts

Primary ContactYonghui Huang, archiater
xuxiao_1028@126.com13911765322

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026