Skip to content

Non-invasive Objective Assessment of Hemodynamics in Preterm Neonates

Non-invasive Objective Assessment of Hemodynamics in Preterm Neonates - the NOAH Study

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04538079
Acronym
NOAH
Enrollment
56
Registered
2020-09-03
Start date
2019-11-09
Completion date
2021-05-31
Last updated
2023-01-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Function, Circulatory Transition, Hemodynamic Instability, Hypoperfusion, Hypotension and Shock, Intraventricular Hemorrhage

Keywords

objective hemodynamic multimodal Monitoring, premature preterm infant

Brief summary

Study type: Prospective Observational trial Study design: Longitudinal Population: Preterm newborns \<32 weeks gestational age Hypothesis: The inclusion of non-invasive physiological measures of cardiac output, peripheral perfusion and brain oxygenation (NIRS) for preterm neonates is feasible and reveals additional information on the hemodynamic status compared to blood pressure alone. These measurements can improve the ability to rapidly identify those infants who might benefit from intervention and are correlated with short term clinical outcomes.

Detailed description

Understanding neonatal hemodynamics is key to neonatal care. Despite decades of research, uncertainty continues as to how best assess impaired hemodynamics. Hypotension defined by a low Mean Arterial Blood Pressure (MABP) remains a common issue in preterm infants, affecting up to 30% of extremely preterm infants. It is common to focus only on MABP thus neglecting the complex and dynamic (patho)physiology that may be present in newborn infants. Providing sufficient cellular oxygenation is the primary task of the circulatory system and different factors may compromise it. In this prospective observational study the investigators will examine various forms of objective non-invasive continuous hemodynamic monitoring methods in very preterm infants 1. For feasibility of non-invasive CO measurement (first 20 patients) 2. For reproducibility and correlation of this measurement and ECHOcardiography (first 40 echocardiographic examinations) 3. For prediction of therapy response. 4. For correlation with clinical definitions of hypotension/hypoperfusion 5. For prediction of later clinical problems/complications of prematurity and impaired hemodynamic status.

Interventions

DEVICEMultimodal objective non-invasive Monitoring

Multimodal objective non-invasive monitoring including cerebral oxygenation (NIRS), pulse oximetry with Pulsatility Index (PI) and non-invasive Cardiac Output Monitoring will be recorded but not used for clinical decision making. 2 ECHOs will be performed (one within the first 24h, one in the 2nd 24 hours after birth)

Sponsors

University College Cork
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Minutes to 20 Hours

Inclusion criteria

* Neonates of 23 weeks 0 days to 31 weeks 6 days * NIRS/non-invasive Cardiac Output - device available * Parental Informed Consent

Exclusion criteria

* Congenital anomalies * Major cardiac defects * Hydrops * Parents decline to consent to the study

Design outcomes

Primary

MeasureTime frameDescription
Adverse Outcome of Circulatory Failure14 daysCorrelation of clinical, laboratory, conventional and multimodal non-invasive monitoring and/or a combination of variables with ultrasound abnormality (IVH grade 3 - 4/any IVH) or death within the first two weeks of life.

Secondary

MeasureTime frameDescription
Reproducibility of absolute right ventricular cardiac output indexed to bodyweight estimated by echocardiography compared to cardiac output estimated by non-invasive Cardiac Output Monitoring48 hoursReproducibility of absolute cardiac output estimated by non-invasive Cardiac Output Monitoring compared to echocardiographic examinations will be performed using right ventricular output \[mL/min\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Reproducibility of superior vena cava flow indexed to bodyweight estimated by non-invasive Cardiac Output Monitoring compared to estimation by echocardiography48 hoursCardiac output estimates of non-invasive Cardiac Output-Monitoring and echocardiographic examinations will be compared using superior vena cava flow indexed to bodyweight \[mL/kg bodyweight/min\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Correlation of non-invasive Cardiac Output Monitoring with echocardiography48 hoursCO-Monitoring and echocardiography will be analysed for correlation using correlation coefficient analysis pairwise for left and right ventricular output indexed to bodyweight \[mL/kg bodyweight/min\], left ventricular pre-ejection period to left ventricular output time ratio and Superior Vena Cava-flow indexed to bodyweight \[mL/kg bodyweight/min\].
Prediction of response to volume/red-blood cell transfusion by Corrected Flow Time estimated with non-invasive Cardiac Output Monitoring48 hoursTreatment Responsiveness (Volume and/or red blood cells responsiveness) using trend analysis within Corrected Flow Time (FTC \[ms\]) for volume responsiveness including a receiver operating characteristic analysis for infants who received volume and/or red blood cells during the study period. (Comparison of 20min mean as baseline before, during and 20min after treatment. Response is defined as normalization of the above mentioned physiological parameters within 20 minutes after receiving treatment.
Prediction of response to volume/red-blood cell transfusion by St roke Volume Variation estimated with non-invasive Cardiac Output Monitoring48 hoursTreatment Responsiveness (Volume and/or red blood cells responsiveness) using trend analysis within Stroke Volume Variation (SVV) for volume responsiveness including a receiver operating characteristic analysis for infants who received volume and/or red blood cells during the study period. (Comparison of 20min mean as baseline before, during and 20min after treatment. Response is defined as normalization of the above mentioned physiological parameters within 20 minutes after receiving treatment.
Prediction of Prediction of response to inotropes by non-invasive Cardiac Output Monitoring response to therapy by non-invasive Cardiac Output Monitoring48 hoursTreatment Responsiveness (Inotrope) using trend analysis within left ventricular cardiac output indexed to bodyweight \[ml/kg bodyweight/min\] for inotrope responsiveness including a receiver operating characteristic analysis for infants who received inotropes during the study period. (Comparison of 20min mean as baseline before, during and 20min after initiation of inotrope treatment. Response is defined as normalization of the above mentioned physiological parameters within 20 minutes after receiving treatment.
Correlation with definitions of hypotension48 hoursCorrelation of multimodal non-invasive monitoring with commonly used definitions of hypotension (Mean Arterial Blood Pressure MABP below 30mmHG and/or MABP below gestational age in weeks)
Feasibility of non-invasive Cardiac Output Monitoring and Pulsatility Index48 hoursThe proportion of infants in whom a continuous recording of non-invasive cardiac output (CO) and perfusion index (PI) analysis was obtained for at least 24 hours during the first 48 hours after birth with a good signal quality index
Reproducibility of absolute left ventricular cardiac output estimated by echocardiography compared to cardiac output estimated by non-invasive Cardiac Output Monitoring48 hoursReproducibility of cardiac output estimates by non-invasive Cardiac Output compared to echocardiographic examinations will be performed using absolute left ventricular output \[mL/min\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Reproducibility of left ventricular cardiac output indexed to bodyweight estimated by echocardiography compared to cardiac output estimated by non-invasive Cardiac Output Monitoring48 hoursReproducibility of cardiac output estimates by non-invasive Cardiac Output compared to echocardiographic examinations will be performed using left ventricular output indexed to bodyweight \[mL/kg bodyweight/min\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Reproducibility of left ventricular stroke volume estimated by echocardiography compared to cardiac output estimated by non-invasive Cardiac Output Monitoring48 hoursReproducibility of left ventricular stroke volume estimates by non-invasive Cardiac Output compared to echocardiographic examinations will be performed using stroke volume \[mL\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Reproducibility of right ventricular cardiac output indexed to bodyweight estimated by echocardiography compared to estimation by non-invasive Cardiac Output Monitoring48 hoursReproducibility of relative right ventricular cardiac output estimates by non-invasive Cardiac Output Monitoring compared to echocardiographic examinations will be performed using right ventricular output indexed to bodyweight \[mL/kg bodyweight/min\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Reproducibility of left ventricular systolic time interval ratio estimated by non-invasive Cardiac Output Monitoring compared to echocardiography48 hoursReproducibility of left ventricular systolic time interval ratio estimates by non-invasive Cardiac Output-Monitoring and echocardiographic examinations will be compared using left ventricular pre-ejection period to left ventricular output time ratio \[no unit\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.
Reproducibility of absolute superior vena cava flow estimated by non-invasive Cardiac Output Monitoring compared to estimation by echocardiography48 hoursCardiac output estimates of non-invasive Cardiac Output-Monitoring and echocardiographic examinations will be compared using absolute superior vena cava flow \[mL/min\]. The Investigators will use Bland-Altman analysis (Bland-Altman plots, Repeatability coefficient. Repeatability Index will be used for between parameter comparison.

Other

MeasureTime frameDescription
Burden and Onset of Hypotension indicating Circulatory Insufficiency48 hoursTime spend with Mean Arterial Blood Pressure (MABP) below 30mmHG and/or MABP below gestational age in weeks
Burden of Cerebral Oxygenation indicating Circulatory Insufficiency48 hoursTime spend wit cerebral regional tissue Saturation (rcStO2) below a value of 60% and/or rcStO2/fraction of tissue oxygen extraction (rcFtO2E) below the infants median value-5%
Burden of Low Cardiac Output indicating Circulatory Insufficiency48 hoursTime spend with Cardiac Output in the lower quartile of the Cohort.
Burden of impaired cerebral Autoregulation48 hoursTime spend with pressure passivity of cerebral regional tissue oxygenation (MABP and or Pulse Pressure to rcStO2/rcFtO2E). Adjusted mutual information and transfer entropy will be used to quantify coupling between MABP or pulse pressure and rcStO2 or rcFtO2E.
Burden of clinical suspicion indicating Circulatory Insufficiency48 hoursOnset and duration of clinical suspicion of Circulatory Insufficiency in clinical examination (i.e. skin colour, increased capillary refill time\>3seconds) as documented in the clinical charts.
Burden of Laboratory parameters indicating Circulatory Insufficiency48 hoursOnset and duration of circulatory insufficiency indicated by laboratory parameters (metabolic acidosis with pH\<7,2 Lactate\>3mmol/L not explainable by intrapartum complications)

Countries

Ireland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026