Skip to content

Compatibility Problems and Prescribing Pattern of Injectable Drugs at the Hospital

Compatibility Problems and Prescribing Pattern of Injectable Drugs at the Hospital

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04523259
Enrollment
127
Registered
2020-08-21
Start date
2009-11-09
Completion date
2013-11-04
Last updated
2020-08-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

IV Injection

Keywords

Drug incompatibility; injections; infusion, intravenous; medication errors

Brief summary

Drug safety is always a national, as well as international, patient safety goal. Administration of injection, especially intravenous infusion, is an extremely complicated and dangerous process, which includes reconstitution, dilution, selection of diluent and volume, verification of concentration of final solution, check for stability, sterility and compatibilities, and the selection of intravenous (IV) set, peripheral or central route, and the rate of infusion. Due to its inherent complexity, errors occur easily during these procedures. Literatures indicated that the incidence of injection administration errors ranged from 13% to 84%, which included errors in dosage, diluents, and volumes; excessive administration rate; and incompatible IV admixture. In the U.S.A., pharmacists provide comprehensive clinical services. They ensure the appropriateness of every step in the process from prescription and dosage verification, drug reconstitution and dilution, selection of diluents and concentration, to the rate of administration. Even more, they provide the final IV products that are ready to administer to the patients (IV admixture services). Therefore, many common administration errors can be avoided. In Taiwan, nevertheless, pharmacists have limited role in IV services due to our health-care system. There are no studies on the administration pattern of injections. There is still room for improvement in the assurance of injection safety. To ensure the safety of injection, we not only have to oversee the accuracy of drugs and dosage, but also take the compatibilities among drugs and diluents seriously. Because diluent is not a mandatory claim data, the National Health Insurance data base cannot provide the related information for drug compatibility epidemiology study. The application for reimbursement of injections is based on total amount used instead of daily usage; it is therefore difficult to find drug incompatibility problems in this data base. Hospital data base analysis, questionnaire survey and chart review are more feasible for such study. This study will analyze the prescriptions of IV injection in the intensive-care units and pediatric units to determine the prescribing pattern. High risk IV admixtures and Y-site administrations will be explored by questionnaire survey and literature review. Laboratory experiments will be done on some indicator drugs to find the reasons, categories and severities of the compatibilities. A list of incompatible drugs shall be generated for computerized intervention. We hope the results of the study can be used as a reference for guideline, policy and procedure for health care system and government.

Interventions

None listed

Sponsors

National Taiwan University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
20 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* nurses

Exclusion criteria

* not nurses

Design outcomes

Primary

MeasureTime frameDescription
Drug incompatibility assessed by questionnaire survey6 monthsIV admixture

Outcome results

None listed