Skip to content

Hearing Aid Processing and Working Memory in Realistic Spatial Conditions

Investigating the Relationship Between Directional Microphones, Compression, and Working Memory in Realistic Spatial Conditions.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04521166
Acronym
DIRWDRCWM
Enrollment
42
Registered
2020-08-20
Start date
2021-05-06
Completion date
2023-06-29
Last updated
2025-09-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss, Sensorineural

Keywords

hearing aids, directional microphones, cognition, compression

Brief summary

The goal of this project is to determine whether the selection of hearing aid settings should be based in part on an individual's cognitive characteristics (specifically, working memory). We anticipate the outcomes of this study to be applicable to realistic listening conditions.

Detailed description

Hearing aids have specialized features to improve access to sounds for the hearing-impaired listener. The choice of appropriate hearing aid settings is integral to the hearing rehabilitative process. Researchers and clinicians have been influenced by previous work showing that individual cognitive abilities, including working memory, are associated with hearing aid benefit, especially in adverse listening conditions. However, previous research is limited to omnidirectional microphone settings and unrealistic listening conditions. Such conditions fail to recognize that most hearing aids are fit with directional processing that may improve the listening environment, and that typical environments contain speech and noise signals in a range of spatial locations. Therefore, the broad goal of this research is to understand how patient variables interact with hearing aid signal processing in realistic listening conditions in order to effectively treat hearing-impaired individuals in communications situations that are most important to them.

Interventions

DEVICEHearing aid

Settings in a wearable hearing aid will be adjusted within a clinically-relevant range for two features. The features include wide dynamic range compression and microphone directionality.

Sponsors

National Institute on Deafness and Other Communication Disorders (NIDCD)
CollaboratorNIH
Northwestern University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
FACTORIAL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Masking description

The participant will be blinded to the hearing aid features being adjusted. The order of presentation of the hearing aid features will be randomized across participants, using a Latin-Square design. The outcomes assessor(s) (who score speech intelligibility) will also be blinded to the conditions.

Intervention model description

Settings in a wearable hearing aid will be adjusted within a clinically-relevant range for two features. The features include wide dynamic range compression and microphone directionality.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* \> =18 years of age; any sex * Sensorineural hearing loss with pure-tone thresholds between 25-70 decibel hearing level (dB HL) at octave frequencies between 250 and 3000 Hz * Speak English as their primary language * Normal or corrected-to-normal vision (\<=20/50) * Participants will be in good health (self-report)

Exclusion criteria

* Clinically significant unstable or progressive medical conditions * Participants who score \< 23 on the cognitive screening test (Montreal Cognitive Assessment) * Evidence of conductive hearing loss or middle ear issues * Significant history of otologic or neurologic disorders * Evidence of significant asymmetry between ears * Non-English-speaking or non-native English speaking

Design outcomes

Primary

MeasureTime frameDescription
Speech Intelligibility (Percent Correct Scores)~20 mins for each intervention over the course of 1-2 daysListeners will listen to and repeat recorded low-context sentences mixed with noise from different spatial locations. Speech intelligibility will be measured immediately following hearing aid fitting. Scoring is determined by percentage of words repeated correctly. Scores range from 0-100% (higher score indicates better performance). This task may take up to 1-2 visits (\ 2 hours each) for different combinations of hearing aid features. The device will only be worn in the laboratory for the duration of the experimental task and will be retrieved by the investigator at the end of each visit.

Countries

United States

Participant flow

Recruitment details

Participants were recruited from the local community in the Chicago area

Participants by arm

ArmCount
Hearing Aid Setting
Hearing aid features presented in this arm include omnidirectional microphone settings, directional microphone settings, fast-acting compression, and slow-acting compression Hearing aid: Settings in a wearable hearing aid will be adjusted within a clinically-relevant range for two features. The features include wide dynamic range compression and microphone directionality.
42
Total42

Baseline characteristics

CharacteristicHearing Aid Setting
Age, Continuous72.76 years
STANDARD_DEVIATION 7.32
Decibel Hearing Level38.38 Decibel Hearing Level
STANDARD_DEVIATION 9.67
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
42 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
42 Participants
Region of Enrollment
United States
42 participants
Sex: Female, Male
Female
21 Participants
Sex: Female, Male
Male
21 Participants
Working Memory Capacity: Percentage of words recalled correctly44.16 Percentage
STANDARD_DEVIATION 11.35

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 0
other
Total, other adverse events
0 / 0
serious
Total, serious adverse events
0 / 0

Outcome results

Primary

Speech Intelligibility (Percent Correct Scores)

Listeners will listen to and repeat recorded low-context sentences mixed with noise from different spatial locations. Speech intelligibility will be measured immediately following hearing aid fitting. Scoring is determined by percentage of words repeated correctly. Scores range from 0-100% (higher score indicates better performance). This task may take up to 1-2 visits (\ 2 hours each) for different combinations of hearing aid features. The device will only be worn in the laboratory for the duration of the experimental task and will be retrieved by the investigator at the end of each visit.

Time frame: ~20 mins for each intervention over the course of 1-2 days

Population: A total of 42 participants were tested for the study. The study design was a full factorial design where each participant completed the outcome measures with all 4 settings in sub-studies 1 \& 2. In Sub-study 3, the outcome measures were completed with Settings 1 \& 3 only. Due to an error in assigning settings, 1 participant each did not listen with settings 1 \& 3 in sub-study 1; 1 participant did not listen with Setting 3 in sub-study 3.

ArmMeasureValue (MEAN)
Setting 1Speech Intelligibility (Percent Correct Scores)0.55 percentage of words correct
Setting 2Speech Intelligibility (Percent Correct Scores)0.59 percentage of words correct
Setting 3Speech Intelligibility (Percent Correct Scores)0.70 percentage of words correct
Setting 4Speech Intelligibility (Percent Correct Scores)0.80 percentage of words correct
p-value: 0.529195% CI: [-0.04075, 0.02095]Mixed Models Analysis
p-value: <0.00195% CI: [0.0988, 0.1671]Mixed Models Analysis
p-value: <0.000195% CI: [0.166, 0.2371]Mixed Models Analysis
Comparison: A linear mixed model was used to assess whether there was an effect of working memory on the primary outcome measure (speech intelligibility) after controlling for age and degree of hearing loss (decibel hearing level)p-value: 0.242Mixed Models Analysis
Comparison: A linear mixed model was used to assess whether there was an effect of working memory on the primary outcome measure (speech intelligibility) after controlling for age and degree of hearing loss (decibel hearing level)p-value: 0.242Mixed Models Analysis
Comparison: A linear mixed model was used to assess whether there was an effect of working memory on the primary outcome measure (speech intelligibility) after accounting for age and degree of hearing loss (decibel hearing level).p-value: 0.242Mixed Models Analysis
Comparison: A linear mixed model was used to assess whether there was an effect of working memory on the primary outcome measure (speech intelligibility) after accounting for age and degree of hearing loss (decibel hearing level).p-value: 0.242Mixed Models Analysis

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026