Skip to content

The Correlation Between Ultrasonography Based Muscle Architecture Parameters and Voluntary Isometric Muscle Strength

Investigation of the Correlation Between Ultrasonography Based Muscle Architecture Parameters and Maximum Voluntary Isometric Knee Flexor Muscle Strength

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04511143
Enrollment
20
Registered
2020-08-13
Start date
2019-01-20
Completion date
2020-08-06
Last updated
2020-08-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ultrasound Imaging

Brief summary

The goal of this study is to investigate potential relations of ultrasound-based muscle architecture parameters and isometric knee flexor muscle strength (IKFS) in healthy individuals. IKFS was measured for twenty participants (22.15±2.41 y.o; 8 females, 12 males) by a hand-held dynamometer. Investigated parameters were total and individual cross-sectional areas (CSA), Muscle-Thickness (MT), and pennation-angle (PA) for Biceps Femoris-long head (LBF), Semitendinosus (ST) and Semimembranosus (SM) muscles at 25%, 50% and 75% length of the thigh.

Detailed description

The images of hamstring muscles were taken by a US device (Toshiba Aplio 500, Japan) with a linear probe (10-12 MHz, with a footprint of 52 mm). For each participant, maximum voluntary IKFS was measured from the non-dominant side in the prone position with foot and ankle stayed outside of the bed. Maximum IKFS (20 limbs) was measured by an HHD (A Lafayette Model 01165) (Lafayette, IN) at 15° knee flexion in prone lying position

Interventions

OTHERmuscle strength and ultrasound imaging measurement

hamstring muscle strenght measured by hand held dynamometer. The long head of Biceps Femoris, Semitendinosus, Semimembronosus were evaluated by B-mode ultrasound imaging.

Sponsors

Istanbul University
CollaboratorOTHER
Istanbul Kültür University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
20 Years to 28 Years

Inclusion criteria

* being healthy young

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frameDescription
The association between IKFS and ultrasound-based muscle architecture in this study will investigate potential relations of ultrasound-based muscle architecture parameters and isometric knee flexor muscle strength (IKFS) in healthy individuals.an average of 1 yearIKFS was measured for twenty participants by a hand-held dynamometer. Investigated parameters were total and individual cross-sectional areas (CSA), Muscle-Thickness (MT), and pennation-angle (PA) for Biceps Femoris-long head (LBF), Semitendinosus (ST) and Semimembranosus (SM) muscles at 25%, 50% and 75% length of the thigh. The association between IKFS and ultrasound-based muscle architecture parameters was assessed.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026