Skip to content

Apple Watch Heart Failure Study

Monitoring Heart Failure Patients Using Heart Rate Variability Measured by the Apple Watch

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04510779
Enrollment
10
Registered
2020-08-12
Start date
2022-05-09
Completion date
2023-12-31
Last updated
2024-06-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Brief summary

This is a pilot/feasibility study on the accuracy of HRV as measured by the Apple Watch on heart failure patients who are admitted to the hospital with heart failure exacerbation. The primary aim is to observe a statistically significant improvement in the HRV of acutely decompensated heart failure patients upon discharge when compared to admission, implying the utility of HRV measured by Apple Watch as a monitor for cardiovascular health.

Detailed description

Heart failure (HF) is a complex clinical syndrome. It is caused by structural or functional impairments, which interfere with the ability of heart muscles to fill or eject blood. The prevalence of HF exceeds 7 million in the United States alone.(1) Despite improving survival, HF hospitalization rates has remained stable, which reflects persisting difficulties in managing existing disease. (2) Specifically, readmission rates may be as high as 50% by 6 months after an admission for HF management. (2) Caring for HF patients exceeds 30 billion annually and is largely driven by hospitalizations.2 Innovative, at-home surveillance tools are needed to reduce hospital admissions and to drive down the overall societal burden of this disease. (3) HF is characterized by periodic exacerbations due to volume overload and fluid congestion that impairs perfusion to the organs.(2) Accurate assessment of volume status is, therefore, key for early detection of impending exacerbation. Currently, there is no single, objective method of assessment, relying on a combination of tools including physical examination, weight, pulmonary artery catheter or echocardiography.(4) However, these measures are subjective, invasive, or impractical for monitoring patients at home. Unique body habitus and comorbidities of individual patient further complicates assessment of volume status.(4) The future of heart failure management, therefore, lies in the development of a telemonitoring system that is convenient to use and accessible for patients at home, while quantitatively understanding individual characteristics.(4) Cardiovascular health is closely related to the imbalances of the autonomic nervous system.(5) Heart rate variability (HRV), the degree of fluctuation in the interval between consecutive heartbeats, has been recognized as a reliable marker of autonomic activity.(5) HRV has been shown to be depressed in patients with congestive heart failure (CHF) and to correlate with disease severity. (6) Furthermore, abnormal HRV parameters are independently associated with incident CHF in asymptomatic, older adults. (7) HRV is conventionally measured using a 24-hour Holter monitor, which is sensitive, but inconvenient and impractical for home monitoring.(5) Newer studies have shown not only the reliability of short term (5-minute) or ultra-short term (\<5 minute) analysis of electrocardiographic recordings, but also that of wearable monitors amenable for use at home.(9-11) In particular, HRV parameters measured by Apple Watch (Cupertino, California) were shown to agree with those measured by a validated chest best heart rate monitor.(12) The usefulness of the study is to validate the utility of wearable heart monitors such as the Apple Watch in accurately measuring heart rate variability, a dynamic marker of cardiovascular health, and correlating it with the health status specifically of heart failure patients. Validating this will allow wearable monitors to record HRV remotely from home, facilitating telemonitoring and preventing hospitalizations.

Interventions

Apple Watch is a smartwatch developed by Apple Inc. The heart rate variability function will be used.

Sponsors

Tufts Medical Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \> or = 22 * Patients admitted to Tufts Medical Center for acute decompensated heart failure * Left ventricular ejection fraction greater than 35% * Able to consent

Exclusion criteria

* Pacemaker rhythm * Arrhythmia, e.g. atrial fibrillation, atrial flutter, frequent ectopic beats * prior history of heart transplant or ventricular assist device * pregnant

Design outcomes

Primary

MeasureTime frameDescription
Difference of Standard Deviation of NN Intervals upon Discharge Compared to Admission1-2 WeeksStandard Deviation of NN Intervals is a time domain heart rate variability parameter. The value upon discharge after medical management should be statistically greater compared to admission value.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026