Skip to content

Study on the Effectiveness and Safety of Coil System for Intracranial Aneurysm Embolization

Study on the Effectiveness and Safety of Coil System for Intracranial Aneurysm Embolization

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04497181
Enrollment
20
Registered
2020-08-04
Start date
2010-03-01
Completion date
2020-12-31
Last updated
2020-08-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Aneurysm

Keywords

intracranial aneurysms embolization

Brief summary

Study on the effectiveness and safety of the coil system for the treatment of intracranial aneurysms embolization was sponsored by Zhuhai Tongqiao Medical Technology Co., Ltd. The trial design is: prospective, multi-center, randomized, open, parallel positive control, and non-inferiority test. Purpose: To compare the data obtained by using the coil system produced by Zhuhai Tongqiao Medical Technology Co., Ltd. and the Axium Detachable Coil produced by Medtronic for the embolization of intracranial aneurysms to evaluate the effectiveness and safety of coil system for intracranial aneurysms embolization.

Detailed description

Study on the effectiveness and safety of the coil system for the treatment of intracranial aneurysms embolization was sponsored by Zhuhai Tongqiao Medical Technology Co., Ltd. The team leader is Shanghai Changhai Hospital and the Second Affiliated Hospital of Zhejiang University School of Medicine. The trial design is: prospective, multi-center, randomized, open, parallel positive control, and non-inferiority test. Purpose: To compare the data obtained by using the coil system produced by Zhuhai Tongqiao Medical Technology Co., Ltd. and the Axium Detachable Coil produced by Medtronic for the embolization of intracranial aneurysms to evaluate the effectiveness and safety of coil system for intracranial aneurysms embolization. Sample: 228 cases. The subjects will be randomly assigned to the test group or the control group, with 114 cases in each group.

Interventions

DEVICECoil embolization surgery

Embolization of aneurysms with various coils system

Sponsors

Second Affiliated Hospital, School of Medicine, Zhejiang University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* An intracranial aneurysm was diagnosed by DSA examination of whole cerebral blood vessels, and it is planned to use a coil for the embolization of the target aneurysm * The subject can understand the purpose of the research, show sufficient compliance with the research protocol, and sign an informed consent form

Exclusion criteria

* Multiple aneurysms * Blood alveolar aneurysm, fusiform aneurysm, pseudoaneurysm, dissecting aneurysm, infectious aneurysm with arteriovenous malformation * mRS score ≥ 3 * Hunt and Hess rating≥4 * Emergency ruptured aneurysms who need stent * The target aneurysm has previously been treated with vascular embolization or surgery * Patients with severe stenosis of the tumor-bearing artery * PLT\<60\*10⁹ or INR\>1.5 * Having vital organ failure or other serious diseases * Received major surgery within 30 days before enrollment, or planned to undergo surgery within 90 days after enrollment * History of allergy or contraindications to antiplatelet drugs, anticoagulant drugs, anesthetics, or contrast agents * Patiens with a history of allergies to platinum and tungsten metals * Life expectancy \<12 months * Pregnant or breastfeeding women * Participated in other drug or device clinical trials within 1 month before signing the informed consent * Other situations that the researcher judges are not suitable for inclusion

Design outcomes

Primary

MeasureTime frameDescription
Embolization success rate6 monthsEmbolization success rate at 6-month after surgery

Secondary

MeasureTime frameDescription
Aneurysm recurrence rate6 monthsAneurysm recurrence rate at 6-month after surgery

Countries

China

Contacts

Primary Contactjianmin zhang, M.D.
zjm135@zju.edu.cn+86 0571 87784755

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026