Skip to content

Sentinel Node in Endometrial Cancer

Sentinel Node in Endometrial Cancer by Detection of Hybrid ([99mTc] Tc-albumin Nanocoloid-ICG). A Comparative Pilot Study Between the Lymphatic Map Derived From the Cervical Puncture Versus Myometrial

Status
UNKNOWN
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04492995
Acronym
HYBRIDENDONOD
Enrollment
70
Registered
2020-07-30
Start date
2020-10-05
Completion date
2023-09-30
Last updated
2023-09-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endometrial Cancer

Brief summary

Phase II, open-label, randomized pilot study. Patients will be randomized (1:1) to receive for sentinel node screening: 1. Radiotracer (RT) via cervical administration and TUMIR 2. Combination of RT with Indocyanine Green (RT + ICG) via cervical administration and TUMIR Patients will be followed up to 1 month after the last administration of radiotracer 70 patients will be included into the study.

Interventions

DIAGNOSTIC_TESTinjection via TUMIR of the tracer [99mTc] Tc-albumin nanocoloid-ICG (6 mCi, 4 ml)

The day before the surgery, a new scan (planar and SPECT / CT) will be performed after the injection via TUMIR of the tracer \[99mTc\] Tc-albumin nanocoloid-ICG (6 mCi, 4 ml) or the injection via TUMIR of \[99mTc\] Tc-albumin nanocoloid (6mCi, 8ml). The two lymphatic maps will be compared and the number of sentinel nodes identified in each study and the territories of drainage and the difference between them (in number and territories) will be established. On the day of surgery, a cervical injection of methylene blue will be performed at the start of surgery according to usual methodology (2 ml diluted to 50%). Intraoperative detection of the sentinel nodes will take place by visual inspection, using the gammadetector probe and NIR optics. Sentinel node biopsies will be processed according to the usual processing methodology and analysis for the detection of metastases.

DIAGNOSTIC_TESTinjection via TUMIR of [99mTc] Tc-albumin nanocoloid (6mCi, 8ml).

The day before the surgery, a new scan (planar and SPECT / CT) will be performed after the injection via TUMIR of the tracer \[99mTc\] Tc-albumin nanocoloid-ICG (6 mCi, 4 ml) or the injection via TUMIR of \[99mTc\] Tc-albumin nanocoloid (6mCi, 8ml). The two lymphatic maps will be compared and the number of sentinel nodes identified in each study and the territories of drainage and the difference between them (in number and territories) will be established. On the day of surgery, a cervical injection of methylene blue will be performed at the start of surgery according to usual methodology (2 ml diluted to 50%). Intraoperative detection of the sentinel nodes will take place by visual inspection, using the gammadetector probe and NIR optics. Sentinel node biopsies will be processed according to the usual processing methodology and analysis for the detection of metastases.

Sponsors

Judit Pich Martínez
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 18 years. 2. Histological diagnosis of endometrial cancer with criteria of high risk according to the following criteria: - unfavorable histology according to FIGO (adenocarcinoma serous, clear cell, or carcinosarcoma) - nuclear grade 3 - suspected myometrial invasion\> 50% by resonance magnetic (MR) or transvaginal ultrasound 3. Women of childbearing age should have a transvaginal ultrasound who rule out pregnancy and must commit to using methods highly effective contraceptives (vasectomized couple and sexual abstinence) until the hysterectomy is performed. 4. Patient who gives written informed consent.

Exclusion criteria

1. Pregnancy or lactation. 2. Suspected lymph node or distant metastatic disease in the preoperative study. 3. History of previous surgery or radiotherapy in the pelvic and paraortic lymphatic drainage areas or nodal involvement of any other etiology. 4. Body mass index (BMI) greater than 45 Kg / m2. 5. Patients who, in the researcher's opinion, are not suitable for participate, regardless of reason, including medical or clinical, or participants potentially at risk of not comply with the study procedures. 6. Known hypersensitivity to some of the active substances or excipients from RT or ICG (including previous history of hypersensitivity to products containing human albumin). 7. Hypersensitivity to sodium iodide. 8. Patients allergic to iodine. 9. Patients with clinical hyperthyroidism, thyroid adenomas autonomic and diffuse focal and autonomic disturbances of the gland thyroid.

Design outcomes

Primary

MeasureTime frame
Proportion of patients with intraoperative detection of sentinel nodes1 month

Secondary

MeasureTime frame
Number of sentinel lymph nodes with lymph node infiltration detected during surgery after injection of hybrid RT or RT by guided myometrial injection by transvaginal ultrasound (TUMIR)1 month
Number of lymph nodes with lymph node infiltration detected in the piece of lymphadenectomy after injection of hybrid RT or RT by TUMIR injection lymphadenectomy after injection of hybrid RT or RT by TUMIR injection1 month
Number of false negative results after injection of the hybrid RT or RT by transvaginal ultrasound-guided myometrial injection (TUMIR).1 month
Difference in the number of sentinel nodes visualized after injection of the hybrid RT or RT between TUMIR lymphogammagraphy and cervical lymphogammagraphy1 month
Difference in the drainage pattern of each radiotracer (hybrid RT and RT) between the cervical injection and transvaginal ultrasound-guided myometrial injection (TUMIR).1 month
Number of sentinel nodes biopsied during surgery after injection of the [99mTc] hybrid radiotracer Tc-albumin nanocoloid-ICG (hybrid RT) or albumin nanocoloid (RT) radiotracer [99mTc] by myometrial injection guided by transvaginal ultrasound (TUMIR).1 month
Difference between the proportion of paraortic sentinel nodes detected after injection of each of the radiotracers (hybrid RT and RT) during surgery.1 month
Proportion of patients with hypersensitivity reactions related to injection of each of the two radiotracers (hybrid RT and RT).1 month
Proportion of patients with adverse events related to injection of one of the two radiotracers (hybrid RT and RT).1 month
Surgical detection time of sentinel nodes during intraoperative detection after injection of each of the two radiotracers (hybrid RT and RT).1 month
Histological data of the tumor: histology, tumor grade, tumor size and myometrial infiltration.1 month
Causes of non-drainage of the hybrid RT or RT in the cervical injection or in the Transvaginal ultrasound-guided myometrial injection (TUMIR).1 month

Countries

Spain

Contacts

Primary ContactPilar Paredes, MD
pparedes@clinic.cat+34932275400
Backup ContactSergi Vidal
svidal@clinic.cat+34932275400

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 9, 2026