Evaluation of Right Ventricular Systolic Function by TAPSE Parameter From Subcostal View

Echocardiographic Evaluation of Right Ventricular Systolic Function by TAPSE Parameter Measured From Subcostal View Using Anatomical M-mode - Validation Clinical Study

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04490538
Enrollment
100
Registered
2020-07-29
Start date
2020-07-27
Completion date
2020-10-31
Last updated
2020-08-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Transthoracic Echocardiography

Brief summary

The purpose of this study is to validate a new echocardiographic parameter evaluating right ventricular function.

Detailed description

The key conventional echocardiographic parameter evaluating right ventricular systolic function is the tricuspid annular plane systolic excursion (TAPSE). It is measured in apical four chamber view by conventional M-mode imaging. Other echocardiographic parameters of right ventricular systolic function (Fractional Area Change; Tricuspid Lateral Annular Systolic Velocity; Right Ventricular Index of Myocardial Performance) are evaluated in apical four chamber view as well. However, this view might not be clearly visible in the clinical setting of critical illness and subcostal view is often preferred for its higher quality. Unfortunately, conventional M-mode can not be used for measurement in this view but anatomical M-mode imaging can. Therefore, the investigators decided to evaluate whether TAPSE measured in subcostal view by anatomical M-mode (sTAPSE) correlates with conventional TAPSE and whether reliably reflects systolic right ventricular function.

Interventions

DIAGNOSTIC_TESTTransthoracic echocardiography

Conventional transthoracic echocardiographic examination at the intensive care unit.

Sponsors

Masaryk Hospital Usti nad Labem
CollaboratorOTHER
Emergency Medical Service of the Central Bohemian Region, Czech Republic
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Inpatients * All patients hospitalised in intensive care unit indicated for transthoracic echocardiography examination

Exclusion criteria

* Age \<18 years * Insufficient imaging quality of transthoracic echocardiography * Refusal of echocardiographic examination by patient

Design outcomes

Primary

MeasureTime frameDescription
Validity of sTAPSE in prediction of right ventricular systolic dysfunctionDuring the interventionsTAPSE is a new potential echocardiographic parameter of right ventricular systolic function measurable from subcostal view.

Secondary

MeasureTime frameDescription
Correlation of sTAPSE with conventional TAPSEDuring the interventionsTAPSE is a new potential echocardiographic parameter of right ventricular systolic function measurable from subcostal view.

Countries

Czechia

Contacts

Primary ContactRoman Skulec, MD, PhD
skulec@email.cz00420777577497