Skip to content

Ultrasound Crestal Bone Topography of Edentulous Ridges

Evaluation of Crestal Bone Topography of Edentulous Ridges: A Retrospective Study Comparing Ultrasonography to Cone-Beam Computed Tomography (CBCT)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04487379
Enrollment
28
Registered
2020-07-27
Start date
2020-06-16
Completion date
2020-12-01
Last updated
2021-01-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ultrasonography

Brief summary

A successful implant surgery primarily relies on a prudent evaluation of oral anatomy and meticulous treatment planning. Additionally, of paramount importance that dictates the types of procedures, material selection and ultimately success of implant surgery is the quality and quantity of the edentulous ridge. Ultrasound imaging (US), another cross-sectional imaging modality, has been extensively used in the medical diagnostics field. The ability of ultrasound to image soft tissue-bone interface makes it particularly promising for studying bone ridge width and crestal bone topography. Therefore, this retrospective human study aimed to compare bone width measurements between US and CBCT. This study also investigated the possible correlation between the crestal bone surface quality imaged by US and CBCT.

Interventions

None listed

Sponsors

University of Michigan
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patient records at the Graduate Periodontal Clinic * With both US and CBCT scans taking within 3 months between each other from Jan 2016 to Mar 2020 * These images had to include at least one edentulous ridge at the anterior, premolar or molar site. * Multiple sites in a given patient may be included.

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of ultrasound for estimating ridge widthup to 3 months after image was takenmeasure the edentulous ridge width at 1, 2 and 3 mm apical to the crest on ultrasound images

Secondary

MeasureTime frameDescription
Accuracy of ultrasound for assessing ridge surface qualityup to 3 months after image was takenEvaluate the crestal bone surface quality with ultrasound

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026